Literature DB >> 35067904

Dosiomic feature comparison between dose-calculation algorithms used for lung stereotactic body radiation therapy.

Takanori Adachi1,2, Mitsuhiro Nakamura3,4, Ryo Kakino1,2, Hideaki Hirashima2, Hiraku Iramina2, Yusuke Tsuruta1,5, Tomohiro Ono2, Nobutaka Mukumoto2, Yuki Miyabe2, Yukinori Matsuo2, Takashi Mizowaki2.   

Abstract

To evaluate the reproducibility of dose-based radiomic (dosiomic) features between dose-calculation algorithms for lung stereotactic body radiation therapy (SBRT). We analyzed 105 patients with early-stage non-small cell lung cancer who underwent lung SBRT between March 2011 and December 2017. Radiation doses of 48, 60, and 70 Gy were prescribed to the isocenter in 4-8 fractions. Dose calculations were performed using X-ray voxel Monte Carlo (XVMC) on the iPlan radiation treatment planning system (RTPS). Thereafter, the radiation doses were recalculated using the Acuros XB (AXB) and analytical anisotropic algorithm (AAA) on the Eclipse RTPS while maintaining the XVMC-calculated monitor units and beam arrangements. A total of 6808 dosiomic features were extracted without preprocessing (112 shape, 144 first-order, and 600 texture features) or with wavelet filters to eight decompositions (1152 first-order and 4800 texture features). Features with absolute pairwise concordance correlation coefficients-|CCcon|-values exceeding or equaling 0.85 were considered highly reproducible. Subgroup analyses were performed considering the wavelet filters and prescribed doses. The numbers of highly reproducible first-order and texture features were 34.8%, 26.9%, and 31.0% for the XVMC-AXB, XVMC-AAA, and AXB-AAA pairs, respectively. The maximum difference between the mean |CCcon| values was 0.70 and 0.11 for the subgroup analyses of wavelet filters and prescribed dose, respectively. The application of wavelet filter-based dosiomic analyses may be limited when using different types of dose-calculation algorithms for lung SBRT.
© 2022. Japanese Society of Radiological Technology and Japan Society of Medical Physics.

Entities:  

Keywords:  Dose-calculation algorithm; Dosiomics; Prescribed dose; Stereotactic body radiation therapy; Wavelet filter

Mesh:

Year:  2022        PMID: 35067904     DOI: 10.1007/s12194-022-00651-9

Source DB:  PubMed          Journal:  Radiol Phys Technol        ISSN: 1865-0333


  2 in total

1.  3D Slicer as an image computing platform for the Quantitative Imaging Network.

Authors:  Andriy Fedorov; Reinhard Beichel; Jayashree Kalpathy-Cramer; Julien Finet; Jean-Christophe Fillion-Robin; Sonia Pujol; Christian Bauer; Dominique Jennings; Fiona Fennessy; Milan Sonka; John Buatti; Stephen Aylward; James V Miller; Steve Pieper; Ron Kikinis
Journal:  Magn Reson Imaging       Date:  2012-07-06       Impact factor: 2.546

2.  A randomized Phase III trial of comparing two dose-fractionations stereotactic body radiotherapy (SBRT) for medically inoperable Stage IA non-small cell lung cancer or small lung lesions clinically diagnosed as primary lung cancer: Japan Clinical Oncology Group Study JCOG1408 (J-SBRT trial).

Authors:  Tomoki Kimura; Yasushi Nagata; Junko Eba; Shuichi Ozawa; Satoshi Ishikura; Taro Shibata; Yoshinori Ito; Masahiro Hiraoka; Yasumasa Nishimura
Journal:  Jpn J Clin Oncol       Date:  2017-01-09       Impact factor: 3.019

  2 in total