High-sensitive cardiac troponin after CPAP in obstructive sleep apnoea: the adjusted analytical change limit (adjACL) for small variations at low concentrations.

Denis Monneret1.   

Abstract

Entities:  

Mesh:

Substances:

Year:  2022        PMID: 35058243      PMCID: PMC8850686          DOI: 10.1183/13993003.03022-2021

Source DB:  PubMed          Journal:  Eur Respir J        ISSN: 0903-1936            Impact factor:   16.671


× No keyword cloud information.
To the Editor: Even below the 99th percentile upper reference limit (99PURL), elevated high-sensitive cardiac troponin concentration (hs-cTn) is associated with increased cardiovascular risk [1]. However, the lower the troponin concentration, the higher the analytical imprecision [2]. It is unclear to what extent a change in hs-cTn (Δhs-cTn) is significant between the limit of detection (LOD) and the 99PURL. Recently, Lui et al. [3] compared, through a randomised control trial, the effect of 8 weeks of continuous positive airway pressure (CPAP) on Δhs-cTnI in subjects with moderate-to-severe obstructive sleep apnoea (OSA) and hypertension. They showed a statistically significant variation compared to untreated subjects (adjusted mean difference −1.74 ng·L−1; p=0.006). The adjusted mean hs-cTnI decreased from 5.6 to 4.8 ng·L−1 (−14.3%) after CPAP, and increased from 7.9 to 8.5 ng·L−1 (+7.6%) in the control group. These values are above the LOD of 1.2 ng·L−1, but are close to the limit of quantification of 5 ng·L−1 (hs-cTnI reagent kit 3P25, Abbott, Chicago, IL, USA). From a diagnostic standpoint, at the individual scale, the reference change value (RCV) concept assumes that the change between two serial results is significant if greater than the sum of the variations for each result. These variations are mostly analytical (analytical coefficient of variation, CVa) and biological (intra-individual, CVi) [2]. Considering two serial results, the RCV is equal to Z×((CVa12+CVi12)+(CVa22+CVi22))1/2, with Z=1.96 for a probability of change of 95%. Considering only analytical imprecision, which mainly depends on assay methods and analysers, as the minimal unavoidable variation, and applying it to serial results, the adjusted analytical change limit (adjACL) is equal to ±1.96×(CVa12+CVa22)1/2 [4]. To test whether the Δhs-cTnI observed after 8 weeks of CPAP was greater than the adjACL of hs-cTnI, we used CVa for hs-cTnI concentrations ranging from 50 to 1 ng·L−1 (mean imprecision profile), provided in the supplementary data from [2], and measured on an Architect Abbott analyser, as did Lui et al. [3]. The regression equation of the best-fit curve was CVa=3.997+(28.17/hs-cTnI) (figure 1). Applying this formula on serial hs-cTnI means of 5.6 and 4.8 ng·L−1 (before and after CPAP), the adjACL was ±26.2%. Hence, at such low concentrations, the Δhs-cTnI of −14.3% is within the adjACL, meaning that the effect of CPAP is not great enough to decrease troponin more than analytical variability. According to this model, a decrease from 5.6 to at least 4.0 ng·L−1 (Δhs-cTnI ≤−28.6%, i.e. out of adjACL ±28.0%) would have been considered as significantly due to CPAP, at least in part. As expected, Δhs-cTnI of the control group (7.9 to 8.5 ng·L−1, +7.6%) remains within the adjACL, calculated at ±20.6%. As demonstrated, the closer the concentrations are to the LOD, the greater the imprecision. This regression model reflects real analytical imprecisions for low ranges of hs-cTnI in the laboratory, with concentrations of 10%CV and 20%CV at 4.7 and 1.8 ng·L−1 [5]. Another analytical consideration is lot-to-lot bias between hs-cTnI reagents and/or calibrators, which can occur over weeks and could partly bias the mean difference of −1.74 ng·L‒1 observed by Lui et al. [3]. Illustrating this, Wu et al. [6] recently showed for Abbott hs-cTnI a lot-to-lot bias at low ranges (below 5.4 ng·L−1) between −1.7 to +2.3 ng·L−1. A large difference of 2.5 ng·L−1 between two successive lots was even observed (from 4.7 to 7.2 ng·L−1), leading the authors to conclude that “a total analytic error <3.5 ng·L−1 for long-term studies with hs-cTnI concentrations <10 ng·L−1 could prevent erroneous reporting of results” [7]. This bias is advantageously considered in the adjACL, since it is also determined over the course of weeks.
FIGURE 1

Mean imprecision profile of high-sensitive cardiac troponin I (hs-cTnI) determined on Architect analyser (Abbott, Chicago, IL, USA), using analytical coefficient of variation (CVa) and mean hs-cTnI concentrations provided in supplementary data from [2]. CVa1 and CVa2 are the analytical coefficients of variation corresponding to the hs-cTnI concentrations before (C1) and after (C2) an 8-week period with (red) or without (green) continuous positive airway pressure (CPAP) treatment, and calculated according to the equation of the nonlinear regression curve. The adjusted analytical change limits (adjACL) were calculated according to the formula ±1.96×(CVa12+CVa22)1/2 [4].

Mean imprecision profile of high-sensitive cardiac troponin I (hs-cTnI) determined on Architect analyser (Abbott, Chicago, IL, USA), using analytical coefficient of variation (CVa) and mean hs-cTnI concentrations provided in supplementary data from [2]. CVa1 and CVa2 are the analytical coefficients of variation corresponding to the hs-cTnI concentrations before (C1) and after (C2) an 8-week period with (red) or without (green) continuous positive airway pressure (CPAP) treatment, and calculated according to the equation of the nonlinear regression curve. The adjusted analytical change limits (adjACL) were calculated according to the formula ±1.96×(CVa12+CVa22)1/2 [4]. Analytical imprecision of troponin is rarely considered in clinical studies, and even less when outcomes rely on serial results. Few studies have evaluated the effect of CPAP on hs-cTnT in OSA, but they overall concluded an absence of significant effect [8, 9]. Lui et al. [3] were the first to focus on Δhs-cTnI under CPAP, furthermore in a well-framed randomised controlled trial. They argued that hs-cTnT is “less sensitive than hs-cTnI in detecting subclinical myocardial injury”, but this is not consensually acknowledged to date. hs-cTnI is more sensitive in the sense that a greater proportion of the general population has detectable concentrations (roughly 75% versus 53% for hs-cTnT), but it also has the drawback of being more strongly associated with age, male sex, body mass index and systolic blood pressure (p<0.0001 for all versus hs-cTnT) [10], making these factors potentially more confounding. Cardiovascular co-morbidities are generally numerous in OSA, most of them impacting troponin levels. This is probably why most studies failed to show beneficial effects of CPAP on cardiovascular outcomes [11, 12]. Further studies interpreting small changes in cardiac troponin at low concentrations under CPAP in OSA should consider the adjACL as an objective criterion, requiring a close collaboration between the clinic and the laboratory. This one-page PDF can be shared freely online. Shareable PDF ERJ-03022-2021.Shareable
  12 in total

Review 1.  Clinical relevance of biological variation of cardiac troponins.

Authors:  Aldo Clerico; Andrea Padoan; Martina Zaninotto; Claudio Passino; Mario Plebani
Journal:  Clin Chem Lab Med       Date:  2020-11-26       Impact factor: 3.694

2.  Total Analytic Error for Low Cardiac Troponin Concentrations (≤10 ng/L) by Use of a High-Sensitivity Cardiac Troponin Assay.

Authors:  Peter A Kavsak; Allan S Jaffe; Dina N Greene; Robert H Christenson; Fred S Apple; Alan H B Wu
Journal:  Clin Chem       Date:  2017-03-21       Impact factor: 8.327

3.  Determination of age- and sex-specific 99th percentiles for high-sensitive troponin T from patients: an analytical imprecision- and partitioning-based approach.

Authors:  Denis Monneret; Martin Gellerstedt; Dominique Bonnefont-Rousselot
Journal:  Clin Chem Lab Med       Date:  2018-04-25       Impact factor: 3.694

4.  Lot-to-Lot Variation for Commercial High-Sensitivity Cardiac Troponin: Can We Realistically Report Down to the Assay's Limit of Detection?

Authors:  Alan H B Wu; Peter A Kavsak; Kristin Moberg Aakre; Robert H Christenson; Dina N Greene; Fred S Apple; W Frank Peacock; Judd E Hollander; James A de Lemos; David Morrow; James Januzzi; Allan S Jaffe
Journal:  Clin Chem       Date:  2020-09-01       Impact factor: 8.327

5.  Comparison between High-Sensitivity Cardiac Troponin T and Cardiac Troponin I in a Large General Population Cohort.

Authors:  Paul Welsh; David Preiss; Anoop S V Shah; David McAllister; Andrew Briggs; Charles Boachie; Alex McConnachie; Caroline Hayward; Sandosh Padmanabhan; Claire Welsh; Mark Woodward; Archie Campbell; David Porteous; Nicholas L Mills; Naveed Sattar
Journal:  Clin Chem       Date:  2018-08-20       Impact factor: 8.327

6.  CPAP for Prevention of Cardiovascular Events in Obstructive Sleep Apnea.

Authors:  R Doug McEvoy; Nick A Antic; Emma Heeley; Yuanming Luo; Qiong Ou; Xilong Zhang; Olga Mediano; Rui Chen; Luciano F Drager; Zhihong Liu; Guofang Chen; Baoliang Du; Nigel McArdle; Sutapa Mukherjee; Manjari Tripathi; Laurent Billot; Qiang Li; Geraldo Lorenzi-Filho; Ferran Barbe; Susan Redline; Jiguang Wang; Hisatomi Arima; Bruce Neal; David P White; Ron R Grunstein; Nanshan Zhong; Craig S Anderson
Journal:  N Engl J Med       Date:  2016-08-28       Impact factor: 91.245

7.  The effects of continuous positive airway pressure therapy on Troponin-T and N-terminal pro B-type natriuretic peptide in patients with obstructive sleep apnoea: a randomised controlled trial.

Authors:  Ya-Shu Chang; Brendon J Yee; Camilla M Hoyos; Keith K Wong; David R Sullivan; Ronald R Grunstein; Craig L Phillips
Journal:  Sleep Med       Date:  2017-09-05       Impact factor: 3.492

Review 8.  Association of Positive Airway Pressure With Cardiovascular Events and Death in Adults With Sleep Apnea: A Systematic Review and Meta-analysis.

Authors:  Jie Yu; Zien Zhou; R Doug McEvoy; Craig S Anderson; Anthony Rodgers; Vlado Perkovic; Bruce Neal
Journal:  JAMA       Date:  2017-07-11       Impact factor: 56.272

Review 9.  High-Sensitivity Cardiac Troponin Concentration and Risk of First-Ever Cardiovascular Outcomes in 154,052 Participants.

Authors:  Peter Willeit; Paul Welsh; Jonathan D W Evans; Lena Tschiderer; Charles Boachie; J Wouter Jukema; Ian Ford; Stella Trompet; David J Stott; Patricia M Kearney; Simon P Mooijaart; Stefan Kiechl; Emanuele Di Angelantonio; Naveed Sattar
Journal:  J Am Coll Cardiol       Date:  2017-08-01       Impact factor: 24.094

10.  Continuous positive airway pressure improves blood pressure and serum cardiovascular biomarkers in obstructive sleep apnoea and hypertension.

Authors:  Macy Mei-Sze Lui; Hung-Fat Tse; David Chi-Leung Lam; Kui-Kai Lau; Carmen Wing-Sze Chan; Mary Sau-Man Ip
Journal:  Eur Respir J       Date:  2021-11-04       Impact factor: 16.671

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.