| Literature DB >> 35054364 |
Camille Gonzalez1,2, Christian Moguet3, Arnaud Chalin4, Saoussen Oueslati1,2, Laurent Dortet1,2,5, Stéphanie Simon3, Hervé Volland3, Thierry Naas1,2,5.
Abstract
Rapid detection of expanded-spectrum cephalosporins (ESC) hydrolysing enzymes is crucial to implement infection control measures and antibiotic stewardship. Here, we have evaluated three biochemical ESC hydrolysis assays (ESBL NDP test, β-LACTA™ test, LFIA-CTX assay) and the NG-Test® CTX-M MULTI that detects CTX-M enzymes, on 93 well-characterized Gram-negative isolates, including 60 Enterobacterales, 21 Pseudomonas spp. and 12 Acinetobacter spp. The performances were good for all three hydrolysis assays, with the LFIA-CTX being slightly more sensitive and specific on the tested panel of isolates especially with Enterobacterales, without ambiguous results. This study showed that LFIA-CTX may be used for the detection of ESC hydrolysis as a competitive alternative to already available assays (β-LACTA™ test and ESBL NDP test) without any specific equipment and reduced hands-on-time. The lateral flow immunoassay NG-Test® CTX-M MULTI has proven to be a useful, easy, rapid, and reliable confirmatory test in Enterobacterales for detection of CTX-M-type ESBLs, which account for most of the resistance mechanisms leading to ESC resistance in Enterobacterales, but it misses rare ESC hydrolysing β-lactamases (AmpC, minor ESBLs, and carbapenemases). Combining it with the LFIA-CTX assay would yield an assay detecting the most frequently-encountered ESBLs (CTX-M-like β-lactamases) together with ESC hydrolysis.Entities:
Keywords: CTX-M; ESBL detection; LFIA; biochemical assay; expanded-spectrum cephalosporin hydrolysis; lateral flow immunoassay; rapid diagnostics
Year: 2022 PMID: 35054364 PMCID: PMC8775164 DOI: 10.3390/diagnostics12010197
Source DB: PubMed Journal: Diagnostics (Basel) ISSN: 2075-4418
Comparison of the three biochemical hydrolysis assays and the NG-Test CTX-M MULTI assay that detects all CTX-M-like enzymes.
| ESBL NDP | ß-LACTA™ | LFIA-CTX | NG-Test®® CTX-M MULTI | |
|---|---|---|---|---|
| Origin | Home-made | Commercial | RUO device | Commercial |
| Substrate used | Cefotaxime | HMRZ-86: chromogenic cephalsporin | Cefotaxime | NA a |
| Detection | Colour change due to acidification of the media as a consequence of hydrolysis | Colour change due to hydrolysis of the chromogenic cephalosporin (HMRZ-86) | Antibodies detecting non-hydrolysed cefotaxime | Antibodies detecting CTX-M enzymes |
| Hands-on time | 15′ | 2′ | 2′ | 2′ |
| Time to results | 15′ incubation | 15′ incubation | 30′ hydrolysis and 10′ migration on the strip | 15′ migration on the strip |
| Incubation Temperature | 37 °C | RT b | RT | RT |
| Bacterial matrix | 3 × 10 µL loop full with 1/3 of bacteria to be tested | One 1 µL loop full of bacteria | One colony | One colony |
| Negative test | Red | Yellow | Absence of a band | Absence of a band |
| Positive test | Orange to Yellow | Red | Presence of a band | Presence of a band |
| Non-Interpretable | Orange | |||
| Required reagents | Tazobactam, cefotaxime, and phenol red solutions needed to be prepared extemporaneously | None (everything is provided) | None (everything is provided in the kit) | None (everything is provided in the kit) |
| Storage | 2–8 °C | 2–8 °C | RT | RT |
| Interpretation | Ambiguous | Ambiguous | Unambiguous | Unambiguous |
a NA: not applicable; b RT: room temperature.
Global performances of the β-LACTA™, ESBL NDP, LFIA-CTX, and NG-Test® CTX-M MULTI tests on different isolates of Enterobacterales, P. aeruginosa, and A. baumannii. Values in brackets are the 95% confidence interval with alpha = 0.05.
| Global ( | ||||||||
|---|---|---|---|---|---|---|---|---|
| Specificity | Sensitivity | Specificity | Sensitivity | Specificity | Sensitivity | Specificity | Sensitivity | |
| β-LACTA™ with NI(+) a | 93% | 89% | 80% | 89% | 100% | 100% | 90% | 90% |
| β-LACTA™ with NI(−) b | 93% | 77 | 80% | 66% | 100% | 72% | 90% | 72% |
| ESBL NDP | 93% | 89% | 80% | 80% | 100% | 82% | 89% | 84% |
| LFIA-CTX | 100% | 100% | 100% | 69% | 100% | 100% | 100% | 94% |
| NG-Test®® CTX-M MULTI (CTX-M-detection) c | 33/33 | 1/1 | 1/1 | 35/35 | ||||
a Calculations with all 13 Non-Interpretable (NI) results considered positive; b calculations with all the 13 Non-Interpretable (NI) results considered negative; c numbers of detected CTX-M producers among the total CTX-M-producers.