Literature DB >> 35038801

[Clinical application of new three-dimensional honeycomb guide in percutaneous cannulated screw fixation of femoral neck fracture].

Feng Gao1, Xiaofeng Wu1, Feng Xu1, Pingkang Qian1, Zifei Yin1, Xueqin Gao1.   

Abstract

OBJECTIVE: To design a new type of three-dimensional honeycomb guide for percutaneous cannulated screw placement in femoral neck fracture and evaluate its effectiveness.
METHODS: The clinical data of 40 patients with femoral neck fracture who met the selection criteria between June 2019 and December 2020 were retrospectively analyzed. According to different intraoperative positioning methods, they were divided into control group (20 cases, free hand positioning screws) and study group (20 cases, new guide assisted positioning screws). There was no significant difference in gender, age, side, cause of injury, Garden classification, and time from injury to operation between the two groups ( P>0.05). The operation time, fluoroscopy times, guide needle puncture times, and fracture healing time of the two groups were recorded. The hip function was evaluated by Harris score at last follow-up. At immediate after operation, the following imaging indexes were used to evaluate the accuracy of screw implantation distribution: screw spacing, screw coverage area, distance from screw to cervical cortex, parallelism between screws, and screw to cervical axial deviation.
RESULTS: All operations were successfully completed, and the guide needle did not penetrate the femoral neck cortex. There was no significant difference in operation time and fluoroscopy times between the two groups ( P>0.05); the guide needle puncture times in the study group was significantly less than that in the control group ( t=8.209, P=0.000). Imaging detection at immediate after operation showed that the screw spacing and screw coverage area in the study group were significantly greater than those in the control group ( P<0.05); the distance from screw to cervical cortex, parallelism between screws, and screw to cervical axial deviation were significantly smaller than those in the control group ( P<0.05). All patients were followed up 7-25 months, with an average of 19.3 months. There was no significant difference in follow-up time between the two groups ( t=-0.349, P=0.729). There were 2 cases of fracture nonunion in the control group and 1 case in the study group, and the other fractures completely healed. One case of osteonecrosis of the femoral head occurred in the control group. During the follow-up, there was no complication such as vascular and nerve injury, venous thrombosis, screw penetration, withdrawal, breakage, and refracture, etc. There was no significant difference in fracture healing time and Harris score at last follow-up between the two groups ( P>0.05).
CONCLUSION: The new three-dimensional honeycomb guide has the advantages of simple structure and convenient use. It can reduce the puncture times of the guide needle and effectively improve the accuracy distribution of cannulated screw implantation.

Entities:  

Keywords:  Femoral neck fracture; cannulated screw; internal fixation; new three-dimensional honeycomb guide

Mesh:

Year:  2022        PMID: 35038801      PMCID: PMC8844631          DOI: 10.7507/1002-1892.202107106

Source DB:  PubMed          Journal:  Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi        ISSN: 1002-1892


  10 in total

1.  Optimum configuration of cannulated hip screws for the fixation of intracapsular hip fractures: a biomechanical study.

Authors:  V T Selvan; M J Oakley; A Rangan; M K Al-Lami
Journal:  Injury       Date:  2004-02       Impact factor: 2.586

2.  Obtuse triangle screw configuration for optimal internal fixation of femoral neck fracture: an anatomical analysis.

Authors:  Qiuliang Zhu; Bengong Shi; Bin Xu; Jianfeng Yuan
Journal:  Hip Int       Date:  2018-05-09       Impact factor: 2.135

Review 3.  Optimizing Stability in Femoral Neck Fracture Fixation.

Authors:  Ye Ye; Jiandong Hao; Cyril Mauffrey; E Mark Hammerberg; Philip F Stahel; David J Hak
Journal:  Orthopedics       Date:  2015-10       Impact factor: 1.390

4.  [Study on biomechanical stability in simulated femoral neck fracture fixation by two cannulated screws].

Authors:  Xiao-Jun He; Hong-Wei Xu; Kang Ji; Zhong-Wei Zhang; Shi-Gui Yan
Journal:  Zhongguo Gu Shang       Date:  2016-11-25

5.  Results of femoral neck screw fixation in 112 under 65-years-old at a minimum 2 years' follow-up.

Authors:  Roger Erivan; Guillaume Fassot; Guillaume Villatte; Aurélien Mulliez; Stéphane Descamps; Stéphane Boisgard
Journal:  Orthop Traumatol Surg Res       Date:  2020-10-10       Impact factor: 2.256

6.  Suboptimal outcomes after internal fixation for displaced intracapsular femoral neck fractures in 50- to 60-year-old patients.

Authors:  Chun-Hung Chang; Shang-Wen Tsai; Po-Kuei Wu; Chao-Ming Chen; Ming-Chau Chang; Wei-Ming Chen; Cheng-Fong Chen
Journal:  Hip Int       Date:  2019-06-23       Impact factor: 2.135

7.  TiRobot-Assisted Percutaneous Cannulated Screw Fixation in the Treatment of Femoral Neck Fractures: A Minimum 2-Year Follow-up of 50 Patients.

Authors:  Zong-Dong Zhu; Cheng-Wei Xiao; Bo Tan; Xiao-Ming Tang; Dan Wei; Jia-Bin Yuan; Jiang Hu; Liao Feng
Journal:  Orthop Surg       Date:  2021-01-15       Impact factor: 2.071

8.  Finite element analysis of fixation effect for femoral neck fracture under different fixation configurations.

Authors:  Haipo Cui; Wenqing Wei; Yinlin Shao; Kewei Du
Journal:  Comput Methods Biomech Biomed Engin       Date:  2021-06-07       Impact factor: 1.763

9.  Proximal Femoral Nail Antirotation in Treatment of Intertrochanteric Hip Fractures: a Retrospective Study in 113 Patients.

Authors:  Sahmir Sadic; Svemir Custovic; Mahir Jasarevuc; Mirsad Fazlic; Ferid Krupic
Journal:  Med Arch       Date:  2015-12

10.  Compression type stress fracture of femoral neck with equivocal X-ray features diagnosed on (99m)Tc-MDP SPECT/CT in a case of trivial hip pain.

Authors:  Saurabh Vitalkar; Ashmi S Manglunia; Arvind Kulkarni; Ameya D Puranik
Journal:  Indian J Nucl Med       Date:  2016 Jul-Sep
  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.