Adrian Tobisch1, Lukas Springsklee1, Lisa-Franziska Schäfer2, Nico Sussmann2, Martin J Lehmann3, Frederik Weis4, Raoul Zöllner2, Jennifer Niessner1. 1. Institute of Flow in Additively Manufactured Porous Media (ISAPS), Heilbronn University of Applied Sciences, Max-Planck-Str. 39, 74081 Heilbronn, Germany. 2. Institute of Automotive Engineering and Mechatronics (IKM), Heilbronn University of Applied Sciences, Max-Planck-Str. 39, 74081 Heilbronn, Germany. 3. MANN+HUMMEL GmbH, Schwieberdinger Straße 126, 71636 Ludwigsburg, Germany. 4. Palas GmbH, Greschbachstrasse 3b, 76229 Karlsruhe, Germany.
Abstract
Aerosol particles are one of the main routes of transmission of COVID-19. Mobile air purifiers are used to reduce the risk of infection indoors. We focus on an air purifier that generates a defined volumetric air flow through a highly efficient filter material. We investigate the transport of aerosol particles from an infected dummy equipped with an aerosol generator to receiving thermal dummies. For analysis, we use up to 12 particle sensors to monitor the particle concentration with high spatial resolution. Based on the measurement data, a computational fluid dynamics (CFD) model is set up and validated. The experimental and numerical methods are used to investigate how the risk of infection suggested by the particle exposure in an exemplary lecture hall can be reduced by a clever choice of orientation of the air purifier. It turns out that obstructing the outlet stream of the air purifier may be particularly advantageous. The particle concentration at the head height deviates by 13% for variations of the location and orientation. At an air change per hour of 5, the cumulated PM1 mass at the head level was reduced by 75%, independently of the location of the infected dummy, compared to the "natural decay" case, showing that filtration is an effective means of reducing aerosol particle concentrations. Finally, CFD simulation was used to monitor the particle fates. The steady simulation results fit quite well with the experimental findings and provide additional information about the particle path and for assessing the comfort level due to air flow.
Aerosol particles are one of the main routes of transmission of COVID-19. Mobile air purifiers are used to reduce the risk of infection indoors. We focus on an air purifier that generates a defined volumetric air flow through a highly efficient filter material. We investigate the transport of aerosol particles from an infected dummy equipped with an aerosol generator to receiving thermal dummies. For analysis, we use up to 12 particle sensors to monitor the particle concentration with high spatial resolution. Based on the measurement data, a computational fluid dynamics (CFD) model is set up and validated. The experimental and numerical methods are used to investigate how the risk of infection suggested by the particle exposure in an exemplary lecture hall can be reduced by a clever choice of orientation of the air purifier. It turns out that obstructing the outlet stream of the air purifier may be particularly advantageous. The particle concentration at the head height deviates by 13% for variations of the location and orientation. At an air change per hour of 5, the cumulated PM1 mass at the head level was reduced by 75%, independently of the location of the infected dummy, compared to the "natural decay" case, showing that filtration is an effective means of reducing aerosol particle concentrations. Finally, CFD simulation was used to monitor the particle fates. The steady simulation results fit quite well with the experimental findings and provide additional information about the particle path and for assessing the comfort level due to air flow.
The COVID-19 pandemic has implied large restrictions to public and private life and has
far-reaching effects on society, culture, science, and the economy. It is well known that a
major route of infection with SARS-CoV-2 is the transmission by aerosol-borne viral
pathogens. These virus-laden aerosols
may be emitted when talking, shouting, singing, coughing, sneezing, or simply breathing.
Small aerosol particles may remain suspended in the air for hours. Infections may occur by proximity when aerosols emitted by
one person are directly transported toward another person. On top of this direct infection
route via droplets, an indirect infection route exists indoors where the aerosol particle
concentration, and thus infection risk, increases with time depending on the number of
persons present, their activity, and the air volume within the room. Since people spend over 90% of their time indoors and several
persons may be infected at a time, indoor situations are most crucial for SARS-CoV-2
transmission. Personal protective
measures, such as masks, will never be able to remove all particles; therefore, ventilation
is of utmost importance as an additional measure. While opening windows very regularly (if
possible) is helpful under warm conditions, air filtration is an important supplement in
spring, autumn, and winter. Discussions about ventilation strategies by opening windows, the
use of face masks during class, lectures, or office work, and the possible risk of infection
are numerous. Understanding and controlling aerosols seem to be the key mechanism to
minimize the infection risks. In this context, computational fluid dynamics (CFD) modeling
is a powerful tool to investigate aerosol particle transport and fate. In addition, recent
advances in sensor network technology provide the possibility not only to measure particle
concentrations at a few locations within a room but also to monitor the aerosol particle
concentration as a measure of infection risk at the locations where particles are
potentially inhaled.While the infection risk through air borne transmission is dependent on multiple factors,
mainly the number of emitted virus-laden particles, the half-life of the virus, and the
number of inhaled viable viruses, lowering the concentration of virus-laden particles in the
air is key to lowering the infection risk of occupants via the indirect infection route
indoors. This can be achieved by either
diluting the air with virus-free fresh air or by removing the aerosol particles using highly
efficient filters. While critical places, such as operating rooms, achieve this through
Heating, Ventilation, and Air Conditioning (HVAC) systems with air changes per hour (ACHs)
ranging from 15 to 406, most HVAC systems in classrooms, theaters, and offices
are not designed to reduce the infection risk but rather to keep the CO2
concentration below the recommended level of 1000 ppm.Mobile air purifiers represent a chance to reduce the aerosol particle concentration by
removing particles from the air using highly efficient filters. For this purpose, ACHs of 5–6 are recommended. Multiple studies have investigated the
decay rates of the aerosol particle concentration using air purifiers at varied ACHs.
Burgmann and Janoske showed that at an
ACH of 6, the aerosol particle concentration is reduced by ∼80% within 30 min. Kähler
et al. reported decay rates ranging from 1.5 to 3.8 h−1,
resulting in half-life times between 10 and 27 min depending on the ACH. In order to
minimize the dwell time of the aerosol particles, Kähler et al. recommended
placing the air purifier in the center of the room if possible. Curtius et al. were able to report a 95%
reduction in the aerosol particle concentration after 37 min using multiple purifiers to
obtain the recommended ACH of 5. The decay rate determined at an ACH of 5.7 was (0.107 ±
0.01) min−1, while the natural decay rate was (0.020 ± 0.01)
min−1.Since the air velocity is larger at the outlet than at the intake, the purified air is
discharged at a greater distance. On
account that aerosol particles move with bulk air, this presents a chance for the air
purifier to disperse the aerosol particles throughout the room, rather than removing
them. Küpper et al.
showed that the clean air delivery rate (CADR) of an air purifier in a small room of
70 m3 is largely independent of its position. By placing the air purifier in a
particular disadvantageous position, the decay rate of the particle concentration and
therefore the CADR decreased.The CADR is determined from Eq. (1) by
measuring the reduction rate k of
aerosol particles (particle size ranging from 0.09 to 11 μm) taking the
natural decay rate k into account in a
standardized test chamber V, while the ACH is calculated using the
volumetric flow rate of the air purifier divided by the room volume. This entails that
although the ACH of a particular air purifier is in line with recommendations, the CADR can
be greatly reduced by a disadvantageous installation,The investigation of the effectiveness of air purifiers in reducing the indoor aerosol
particle concentration often combines experimental and numerical methods. This allows for
the examination of multiple cases using validated CFD models while minimizing experimental
effort. Multiple studies have modeled the transport of aerosol particles indoors. In these
publications, various results of the importance of humidity and the thermal effects to a
numerical particle simulation are discussed.Feng et al. showed that
most numerical studies report that condensation and evaporation due to humidity have a
negligible effect on the particle distribution. Chen et al. and Farkas et al. focused on the deposition of multicomponent
droplets and evaporation in a human respiratory tract. Feng et al. faced this question of humidity and
evaporation effects in indoor conditions, like in this study of a lecture hall. Xie
et al. showed that
the evaporation time of water aerosols with a diameter of a few micrometers is less than one
second. In preliminary simulation studies, this effect has been confirmed by the authors
using ANSYS Fluent. Mutuku et al. investigated different turbulence models and solver algorithms for
particle simulations. In most studies, an Euler–Lagrange method is used to simulate a
multiphase particle flow. Due to the low
mass loading, a one-way coupling is used for fluid particle interactions. Regarding the continuous phase, it can be
assumed that an indoor air flow is incompressible and turbulent.For turbulence modeling, Abuhegazy et al. used a k − ɛ model following the
Reynolds-averaged Navier–Stokes equation (RANS) approach since the time-averaged results are
often of interest. Modeling the discrete phase, the particle diameter distribution is
important for the simulation. Brownian
particular motion can be neglected because the particle diameters are still too large. In the simulation of air purifiers using
highly efficient particle filters (HEPA class H13 and higher), it can be assumed that 100%
of the particles get removed.In contrast to this study in a lecture hall, Dbouk and Drikakis investigated aerosol dispersion in very confined spaces as
in an elevator and pointed out that the location of the inlets and outlets has a significant
influence on the aerosol distribution. A larger outdoor environment is investigated by
Gorbunov who showed in a simulation
that aerosol particles can travel over a distance of 30 m. Bathula et
al. used simulation to
investigate how long infectious particles remain in a room. This has practical implication
regarding the safety of medical staff. Pyankov et al. presented a study of time-dependent inactivation of
MERS-CoV in ambient air under climatic conditions representing a common office environment.
An alternative way of reducing infection risk is to inactivate the virus rather than
removing aerosol particles. Rezaei et al. investigated virus elimination by heat in air conditioning systems
to reduce the amount of contaminated particles.Another study on virus inactivation by UV-C irradiation is investigated by using numerical
simulations of virus-laden droplets.
However, particles are still contaminated on the path from the source to the air cleaner,
like when using common filtrating air purifiers.The literature review shows investigations of the general dispersion of aerosols in
different rooms and under different conditions. However, the studies do not focus on the
particle load that the persons are exposed to at their seat positions. Consequently, in this
study, we investigate the particle concentration at positions where particles may be inhaled
by persons using a high spatial resolution.Therefore, the purpose of this work is given as follows:To assess the influence of the position and the orientation of an air purifier on the
aerosol particle concentration within the room and to identify preferable cases.To investigate the particle exposure of persons by measuring particle concentrations
using a sensor network consisting of 12 PM1 sensors exactly at the locations where
particles may be inhaled.To include the influence of thermal buoyancy by mimicking the effect of persons
present in the room using “thermal dummies”.To investigate particle concentrations for the case that a sink (air purifier) fights
against a source (infected person) and by studying commonly considered decay.To validate a CFD model based on the measurements in order to (1) increase process
understanding by allowing for a visualization of the flow field in a room and (2)
allow for the investigation of situations that can hardly or not be considered
experimentally.In Sec. II, we give an overview on the situation in
the lecture hall considered, the experimental material, and the setup. Next, in Sec. III, we introduce the mathematical and numerical models and
give an overview on the considered cases. The numerical model is validated in Sec. IV, and both numerical and experimental results are
presented and discussed. Finally, we sum up and give an outlook on future research in Sec.
VI.
SITUATION AND EXPERIMENTAL SETUP
Experiments were performed in a lecture hall at the Heilbronn University of Applied
Sciences. The dimension of the room is 11 × 8.5 × 3 m. Due to the ascending rows, the
ceiling height in the back of the room is significantly lower, resulting in a room volume of
∼250 m3. The room provides seating for up to 80 students and one professor. The
total window area is 20 m2, of which 6 m2 can be used for
ventilation.The HVAC system is turned off during the entirety of the experiments. The room is equipped
with a portable air purifier (SQ 2500, MANN + HUMMEL) capable of a maximum volumetric air
flow of 2500 m3/h, delivering a maximum theoretical ACH of 10. The air purifier
is fitted with an HEPA H14 filter that gets removed at minimum 99 975% of particles at the
most penetrating particle size (MPPS).
The intake is located at the front side and has an area of 0.32 m2. The outlet is
on a side of the device adjacent to this front side and has an area of 0.28 m2.
The air flow of the device is denoted by the arrows seen in Fig. 1 (left). Up to nine thermal dummies are deployed to simulate the heat flux
contribution of persons in the room, in addition to serving as obstacles for the flow. The
dummies are made of cardboard equipped with light bulbs emitting a thermal energy of ∼75 W
in accordance with the thermal contribution of students in a lecture scenario specified by
DIN EN 16798-1. The room is equipped with
up to 12 particle sensors, made up of four high-end optical particle counters (OPCs) (Fidas
Frog, PALAS) and a network of eight low-cost photometric particle sensors (lcps) (SPS 30,
SENSIRION). The temperature, ambient pressure, and relative humidity are measured at each
point. Each device measures aerosol particles in the size range of 0.18–18
μm (Fidas Frog) or 0.3–10 μm (SPS 30). The high-end
devices are deployed to measure particles at the table height, while the low-cost sensors
are placed at the “face height” of the dummies. The aerosol particles are produced using an
atomizer (AGK 2000, PALAS) with a sodium chloride solution. The emitted particle size
distribution is adjusted via the mass concentration of the saline solution, while the mass
flow is set through the applied compressed air pressure.
FIG. 1.
Position of the air purifier, receiving and emitting thermal dummies (marked by green
and orange circles), and high-end optical particle counters (OPCs) (marked blue).
Position of the air purifier, receiving and emitting thermal dummies (marked by green
and orange circles), and high-end optical particle counters (OPCs) (marked blue).
Influence of the position, orientation, and flow rate
In the first experimental setup, the influence of the position, orientation, and flow
rate of the air purifier on the spreading and degradation of the aerosol particle
concentration is investigated. For this purpose, the aerosol particles are emitted in a
fixed place in the center of the room using compressed air at 3.5 bars and a sodium
chloride solution of 2.5 wt. %. The particle counters are positioned at the table height
at the measurement points MP 26, MP 58, MP 86, and MP 52 (see Fig. 1). The experiments consist of two phases. In the first phase, the
aerosol particles are emitted for a duration of 20 min, after which the atomizer is shut
off and the decay of the particle concentration is monitored. The air purifier is
positioned at four different locations throughout the room, and at each position, the
orientation is varied so that the inlet and outlet point in different directions into the
room or against an obstacle, in this case either the window front or the wall. If the
outlet and/or intake are pointed at an obstacle (either the wall or window) at a distance
of 0.3–1 m, they are considered to be obstructed, and if they point freely into the room,
they are considered unobstructed.The following positions are identified as viable places to set up the mobile air purifier
(see Fig. 1):NE: North-East near the window panel;N: North near the window panel;NW: North-West near the window panel;SW: South-West near the wall.At most locations, particular orientations are disqualified as viable setup options due
to proximity to students or the professor, therefore likely exceeding air velocity limits
for thermal comfort. The position and orientation of the air purifier are encoded using
the cardinal direction relative to the compass seen in Fig.
1 to identify the location, appended by the air flow direction at the intake of
the air purifier. This leaves the following cases for the experimental setup:NE-N and NE-E;N-E;NW-N, NW-W, NW-S, and NW-E;SW-N, SW-W, and SW-S.The effectiveness of the operation parameters of the mobile air purifier (position and
orientation) is evaluated by the numerical integration of the mass concentration of
particles smaller than 1 μm (PM1 fraction) over the duration of the
experiment. This is due to the fact that virus-laden droplet nuclei are known to be in a
size regime <1 μm.
The value is then multiplied by 1.333 · 10−4 m3/s (8 L/min),
representing the volume flow rate of a breathing person in a relaxed condition. This gives
an average mass of PM1, which is inhaled at the measuring point over the duration of the
experiment. Splitting up into the charging and decaying phases of the experiments, this
value is used to identify the PM1 dose potentially inhaled at each measurement
point throughout the classroom. By fitting the decay curve with an exponential decay
functionthe decay rate
k at each measurement point is
determined.
Influence of the particle source on local particle exposure
The second experimental setup focuses on the influence of the position of the aerosol
particle source on the distribution and decay of particles for the fixed positions and
orientation of the air purifier. Derived from the first experimental setup, the following
three cases are identified for further investigation: SW-W, SW-N, and SW-S. These cases
represent a corner installation with an obstructed outlet (SW-W), obstructed outlet and
intake (SW-N), and unobstructed outlet and intake (SW-S). The fourth case is a reference
case where the air purifier is turned off. Nine thermal dummies are positioned throughout
the room at a maximum distance to each other, as shown in Fig. 1. The location of the aerosol particle source is varied. The aerosol
particles were emitted at seats 29, 46, and 80. The particle concentration at the table
height and “face-height” of the dummies is measured.
NUMERICAL SETUP
In addition to the experimental studies, numerical flow simulations are performed to
achieve a deeper insight into the indoor air flow and the aerosol distribution. Additional
cases are considered that can hardly be implemented in the experimental setup.
Numerical approach
Two different numerical approaches of multiphase flows have been established:
Euler–Lagrange approach and Euler–Euler approach. In particle laden flows with a low mass
loading, the Lagrangian approach is advantageous. It is assumed that a mass point approach
with the approximation of the forces by particle volume is sufficient. Therefore, the
particles are assumed to be spherical. Due to the low mass loading of less than 10%, an
Euler–Lagrange approach with a discrete phase model (DPM) and a one-way-coupling is used
for the numerical simulations. The continuous phase influences the discrete phase by
friction and turbulence. However, the particles do not influence the flow.
Governing equations for the Euler–Lagrange approach
Continuous phase: In this case, the flow field is calculated before the discrete phase
calculation. Therefore, there is no influence of the particles on the flow field, and
the classical Navier–Stokes equations are solved,Index F represents fluid parameters. The density is denoted by
ρ, the flow velocity vector , the pressure p, and the shear stress
tensor . Additional accelerations, such as gravitation, are
considered in variables , specific internal energy e, specific
enthalpy h, and Fourier’s law of heat conduction
−λ∇T. Furthermore, the RANS averaging, the transport
equations of the k − ɛ turbulence model, and other
additional equations, such as the incompressible ideal gas law, are considered.Because an exchange of mass, momentum, and energy is not considered, the Lagrangian
equations can be highly simplified. The particle inertia can be written as in Ref. 31,with diameter d and drag
coefficient C, which is calculated
using the spherical drag law. Index P represents particle parameters.
All other additional accelerations, such as the Saffman lift force and gravitation in
this case, are represented by . The vector represents the position of the particle.
Discrete phase model
In this parameter study, a steady particle tracking based on a fixed steady airflow is
solved with ANSYS Fluent. Due to the low mass fraction, the one-way-coupling is applied.
Nevertheless, a two-way-coupling is activated to use further result variables. The
influence of the particles on the flow is prevented by calculating the steady-state flow
solution first without particles. Then, the Navier–Stokes equations are deactivated, and
one Lagrangian iteration is calculated separately.In a pre-analysis, it was examined whether the evaporation of the water component of
the particles has to be considered for the simulation. A mass fraction of about 10.4%
NaCl and 89.6% water is assumed.
According to the settings of Feng et al., the initial droplet diameters are fixed at 2
μm, which represents the smallest droplet diameter in their study.
Compared to the aerosol particle diameter distribution used in this study, this
represents a larger particle with a corresponding long evaporation time. An initial
relative humidity of 0% is defined in the domain for the pre-analysis. The results show
that the liquid water only exists for an average time of 0.024 s before it is completely
evaporated. During this time, the particle trajectories travel about 1 mm. The range of
influence of the gaseous water due to diffusion is limited to about 80 cm. In the
following simulations, evaporation effects are neglected, and only solid particles are
emitted directly from the particle source.
Inert particle setup
The inert particles of solid sodium chloride are injected in a 60° cone shape. The
injection occurs at a spatial radius of 0.01 m. The initial velocity of the particles is
set to 0.47 m/s at a total flow rate of 8.625 · 10 −10 kg/s. The activation
of the Saffman law allows lift forces in shear flows. Based on the measured particle
size distribution, the analytic Rosin–Rammler distribution is used to adjust the
particle diameters in the simulations to the experimental diameter distribution of the
aerosol generator. This distribution is defined by the following parameters: minimal
diameter, 0.19 · 10 −6 m; maximum diameter, 9.65 · 10−6 m; mean
diameter, 3.57 · 10−6 m; and a spread parameter, 1.90. A stochastically
random walk model of 10 leads to a total number of 10000 trajectories that are
calculated in a simulation. The maximum number of steps of 100000 and a step length
factor of 5 define the tracking parameters and the abort criteria if a particle stream
does not reach a target boundary. For the calculation of the trajectories, an automatic
adaptive time step is used. It is assumed that particles stick on all solid surfaces due
to van der Waals forces. Complete
reflection and reentry of particles at the door gap and pressure side of the purifier
are assumed. Particles can escape the domain at the intake of the air purifier.
CFD setup
The turbulence modeling is performed using the k − ɛ
realizable model with the Menter–Lechner wall treatment. It is assumed that the airflow
in the room is steady. According to the incompressible ideal gas law, thermally induced
buoyancy flows are considered. At low temperatures and normal room temperature, heat
transfer by radiation can be neglected. According to DIN EN 13779, persons in the classroom represent a heat source with a heat
flux of . In winter, the window surface temperature cools down and
radiators are used. The thermal
power loss of the air purifier is adapted according to the power level of the fan. The
equations are solved in a coupled scheme. The Navier–Stokes equations are discretized
with a second order method in space. The two additional transport equations for the
turbulence modeling are solved with first order accuracy.
Case studies
Due to the steady-state flow simulation, particle charging and decaying phases cannot be
considered as in the experiments. Based on a steady-state flow field, the Lagrangian
solution still provides time-dependent information and allows for a validation by
comparison with the experimental results. First, simulations are performed to validate the
setup and to compare the results with experimental data. When investigating the influence
of the location of the air purifier and particle source on the local aerosol
concentration, the simulations are performed according to the experiments. In addition,
the visualization of the room air flow will provide further references for the operating
conditions of air purifiers. A comparison of summer and winter cases shall determine the
influence of cold window surfaces and warm radiators.
RESULTS AND DISCUSSION
Experimental results
The experimental results are split up into the validation of the measurement method, the
decay rate comparison of the high-end OPC and low-cost particle sensors, the evaluation of
the position and orientation of the air purifier, and the influence of the position of the
aerosol particle source on local exposure.
Validation of instruments and measurement method
In order to validate the measurement method, five low-cost particle sensors are placed
along a grid at the face-height of a single thermal dummy and one high-end OPC is placed
at the table height for comparison (see Fig.
2).
FIG. 2.
Four low-cost particle sensors are cycled around a central sensor at the
face-height of a thermal dummy. A high-end OPC on the table is used as a
reference.
Four low-cost particle sensors are cycled around a central sensor at the
face-height of a thermal dummy. A high-end OPC on the table is used as a
reference.The air purifier is positioned in the south-western corner of the classroom and
oriented so that the outlet points toward the front of the room (SW-S). The aerosol
particles are emitted at the back of the room near the air purifier (position 80; see
Fig. 1). After 4 min of measuring the ambient
particle concentration, the atomizer (3.5 bar; 16 wt. % NaCl solution) and air purifier
(ACH: 5) are turned on. After 20 min of charging the room with particles, the atomizer
is shut off and the air purifier kept running for further 20 min. To distinguish between
potential spatial concentration differences, in further experiments, the central sensor
unit is fixed in place, while the surrounding sensors are cycled around the center
point (experiments V1–V4).The PM1 dose at each point is set in relation to the center point value. A comparison
of the PM1 doses at each measuring point (Fig. 3,
right) and the PM1 dose measured by each device relative to the center point (Fig. 3, left) shows a consistent offset between the
single devices independent of their respective location. The high-end OPC (MP 46)
consistently measures a 20%–30% higher PM1 dose. This is due to the wider measuring
range and a more precise measurement at high particle counts (>5000
P/cm3). Although the exact PM1 mass concentration is subjected to
uncertainties due to the varying measurement precision of the low-cost and high-end
sensors, the reduction in the relative PM1 exposure at either the table height or face
height and the decay rate at each measurement point can be used to evaluate the
efficiency of the air purifier depending on the operating parameters.
FIG. 3.
Left: relative PM1 dose in relation to the center measurement point by the device.
Right: relative PM1 dose measured by the location.
Left: relative PM1 dose in relation to the center measurement point by the device.
Right: relative PM1 dose measured by the location.
Decay rate of low-cost and high-end sensors
Figure 4 shows the temporal PM1 mass concentration
curve of an exemplary validation experiment. Regression coefficients R2 >
0.99 show a high correlation between the fitted decay curves and measured data. The
decay rate at a single point in the room at an ACH of 5 and 10 are (0.092 ± 0.001)
min−1 and (0.188 ± 0.002) min−1, respectively. In this case, 50%
of the initial particle concentration decay after (7.52 ± 0.09) min at an ACH of 5.
Increasing the ACH to 10 gives a half-life time of (3.63 ± 0.04) min, while 99% of the
initial particle concentration decays after (24.6 ± 0.7) min. Using Eq. (1), with the natural decay rate of
knatural = 0.008 min−1 and the room volume of 250 m3,
the resulting CADRs are calculated to be 1260 and 2700 m3/h.
FIG. 4.
Temporal PM1 mass concentration of an exemplary validation experiment showing the
charging and decay phases.
Temporal PM1 mass concentration of an exemplary validation experiment showing the
charging and decay phases.
Evaluation of the position and orientation of the air purifier
The influence of the position and orientation of the air purifier on the distribution
and decay of the aerosol particles was evaluated by comparing the PM1 dose at four
measurement points using the high-end OPCs. In Fig.
5 (left), the PM1 dose at each measurement point is shown. The location of the
air purifier has a noticeable impact on the distribution of the emitted particles. While
in the absence of an air purifier, the emitted particles initially follow the thermally
induced air flow by the measurement point MP 58 (located between the particle source in
the middle of the room and the window front), operating the air purifier leads to an
increased PM1 concentration at measurement points close to the intake. For positions NE
and N, this is MP 58. Positions NW and SW show the increased concentration at points MP
86 (back of the room) and MP 52 (near wall). In the case of NE-E, the emitted particles
traveled to the intake without passing by the OPC, leading to a minimal PM1 dose
measured in this setup. This example clarifies that a high spatial resolution is
necessary especially during the charging phase where it cannot be assumed that the
particle concentration is homogeneous throughout the room. In order to evaluate the
setup parameters of the air purifier, the calculated PM1 doses were averaged within
three setup categories: (I) the air purifier outlet is obstructed (oriented in such a
way that the outlet points toward the wall or window), (II) the outlet is unobstructed
(oriented in such a way that the outlet points freely into the room), and (III) the
outlet and intake are obstructed (oriented in such a way that both the outlet and the
intake are obstructed by either a wall or a window). Figure 5 (right) shows the average PM1 doses for categories I, II, and III
over both charging and decay phases and split up into each phase.
FIG. 5.
Left: PM1 dose at each measurement point for all investigated setup parameters at
an ACH of 5. Right: averaged PM1 dose by the setup category at an ACH of 5.
Left: PM1 dose at each measurement point for all investigated setup parameters at
an ACH of 5. Right: averaged PM1 dose by the setup category at an ACH of 5.In all cases, the air purifier reduces the particle load compared to the natural decay.
Setting up the air purifier by obstructing the outlet leads to an average 70% reduction
of the total PM1 dose over the charging and decay phases. By pointing the outlet stream
unobstructed into the room, the PM1 dose is only reduced by an average of 58%. This is
attributed to the outlet stream distributing the emitted aerosol particles throughout
the room during the charging phase rather than depositing them. Obstructing the outlet
and the intake of the air purifier is particularly disadvantageous, leading to an
average PM1 dose reduction of only 30% while showing a PM1 dose comparable to the
absence of the air purifier during the charging phase. It can be concluded that the
orientation of the air purifier has a significant impact on the efficiency of the
reduction of the airborne particulate matter. In this case, obstructing the outlet
stream reduces the distribution of the aerosol particles throughout the room. This
ensures that the air purifier is employed at maximum efficiency.
Influence of the aerosol particle source on local exposure
Derived from the results of the first experimental setup, four cases are investigated
further (SW-W, SW-S, SW-N, and no air purifier). The new experimental setup includes
nine thermal dummies equipped with low-cost sensors at the face-height and varying
positions of the aerosol particle source (see Fig.
6). The PM1 dose over the course of the experiment is set in relation to the
PM1 dose measured using no air purifier (see Fig.
7, left).
FIG. 6.
Experimental setup showing the location of the air purifier, aerosol source
positions (orange), measurement points (orange and green), and an air velocity
larger than 0.1 m/s for position SW-W at an ACH of 5.
FIG. 7.
Left: PM1 dose at the face height in the absence of the air purifier. Right: PM1
dose at the face height for positions SW-W and SW-S depending on the aerosol source
(29, 46, and 80) at an ACH of 5.
Experimental setup showing the location of the air purifier, aerosol source
positions (orange), measurement points (orange and green), and an air velocity
larger than 0.1 m/s for position SW-W at an ACH of 5.Left: PM1 dose at the face height in the absence of the air purifier. Right: PM1
dose at the face height for positions SW-W and SW-S depending on the aerosol source
(29, 46, and 80) at an ACH of 5.Overall, the use of the air purifier decreases the PM1 dose independently of the
aerosol source compared to no air purifier (see Fig.
7, right). The highest reduction was achieved with the outlet directed at the
wall (setup parameter, SW-W), decreasing the PM1 dose throughout the room on average by
75% independently of the aerosol source position. This is slightly higher than the
reduction determined in the first experimental setup due to the fact that emitting
particles near the intake leads to an overall reduction of well above 80%. SW-N
decreases the PM1 dose throughout the room on average by 61%. In this worst-case
scenario (both the intake and outlet are obstructed), the aerosol particles are emitted
from seat 29 at a significant distance to the air purifier. Further dependency on the
aerosol source position is not investigated. The last case with an unobstructed intake
and outlet (SW-S) decreases the PM1 dose throughout the room on average by 61%. This is
very close to the 58% reduction of the PM1 particle concentration measured in the first
experimental setup for the unobstructed intake and outlet. Regarding the charging phase,
SW-S leads to localized increases in the PM1 dose compared to no air purifier, further
indicating that an unobstructed outlet negatively effects the removal of the aerosol
particles. SW-W holds up to be the best setup case, showing the lowest increase in the
PM1 dose during the charging phase independently of the location of the aerosol source
and indicating that obstructing the outlet air flow is a viable strategy in preventing
the distribution of particles throughout the room.
Numerical results
Validation of the numerical model
The impact of the mesh on the results of the CFD simulation is investigated. Starting
from a fine mesh, the grid is coarsened and the resulting differences are evaluated.Using a fine and medium mesh, similar vortex structures can be seen at a head height of
1.7 m (see Fig. 8). In contrast, when using the
coarse mesh, different flow vortices occur in the center of the room. Even though the
faster flow velocity larger than 0.1 m/s of all mesh variants corresponds very well to
the results using the fine mesh, different aerosol particle dispersion occurs. The
particle trajectories take different paths because of the slow flow vortices in the
center of the room where the particles are injected. The medium mesh settings are used
as a compromise between computational duration and accuracy.
FIG. 8.
Comparison of vortex structures in slow flow regions on different meshes. (a) Fine
mesh, (b) medium mesh, and (c) coarse mesh.
Comparison of vortex structures in slow flow regions on different meshes. (a) Fine
mesh, (b) medium mesh, and (c) coarse mesh.
Validation using steady particle tracking
A validation of the simulation results is done based on the stationary particle
simulation since this is also used in the simulation study. Here, temporal information
is only available in the Lagrangian phase.After 60 s, the particles have barely dispersed. No measuring device should react to
the turned-on aerosol source [see Fig. 9(a)]. After
about 2 min, the particles have arrived at MP58 and MP86. MP58 is exposed to the most
particles [see Fig. 9(b)]. MP26 and MP52 do not
show any measurement data yet. After about 3 min, the particle trajectories pass MP52
[see Fig. 9(c)]. At MP26 near the placement of the
air purifier, the first particles from the aerosol generator are measured only after
4 min [see Fig. 9(d)]. This matches to the
experimental data in Fig. 10.
FIG. 9.
Dispersion of Lagrange particles using steady particle tracking for validation with
measurement data. (a) t = 60 s, (b) t = 120 s, (c) t = 180 s, and (d) t = 240 s.
FIG. 10.
Comparison of the particle mass concentration determined experimentally (left) and
unsteady simulation (right) at four different measurement locations at an ACH of
5.
Dispersion of Lagrange particles using steady particle tracking for validation with
measurement data. (a) t = 60 s, (b) t = 120 s, (c) t = 180 s, and (d) t = 240 s.Comparison of the particle mass concentration determined experimentally (left) and
unsteady simulation (right) at four different measurement locations at an ACH of
5.
Validation using unsteady particle tracking
A transient particle simulation can offer further information for the validation of the
simulation settings to the experimental measurement results. To evaluate the mass
concentration spatially and temporally, control volumes have to be defined according to
the position of the OPCs.The order of magnitude and the time evolution of the mass concentration at the control
volumes match to the experimental data at the measurement locations.
Influence of the air purifier and particle source on local particle
exposure
The analysis of the air flow at different positions of the air purifier already gives
an insight into the aerosol distribution. According to DIN EN ISO 7730, a maximum
average air velocity of 0.24 m/s is specified for classrooms. In all cases, the flow velocity at the occupied seats
is low enough not to cause thermal discomfort (see Fig.
11).
FIG. 11.
Comparison of different air purifier positions and air velocities at an ACH of 5.
(a) Position NE-N, (b) Position SW-W, (c) Position SW-N.
Comparison of different air purifier positions and air velocities at an ACH of 5.
(a) Position NE-N, (b) Position SW-W, (c) Position SW-N.The fates describe the number of particle streams arriving at a defined target
boundary. The different labels represent different particle source positions. The data
series represent the different locations of the air purifier in Fig. 12. Particles that reach the air purifier can be removed from
the ambient air. This reduces the amount of potentially infectious particles. The
plotted data show the relative number of particle streams that are collected in the
filter at an ACH of 5, allowing us to compare different positions and orientations of
the air purifier at the same filter volume flow.
FIG. 12.
Particle fates for different purifier positions and different particle source
positions at an ACH of 5.
Particle fates for different purifier positions and different particle source
positions at an ACH of 5.In air purifier position SW-N, it is noticeable how strongly the number of filtered
streams depends on the source position. In the worst case, only about 5% of the particle
streams reach the filter. Due to this strong dependence of the source position, the
purifier position SW-N is not recommended. Position NE-N shows the best uniformity of
the number of filtered streams. However, this is at a generally low level so that on
average only about 28% of the injected particle streams arrive at the air purifier.
Position SW-W achieved the best results in this comparison. On average, about 40% of the
emitted particle streams reach the room air purifier. In the worst case, still about 25%
of the particle streams are removed by the filter. The positioning of the room air
filter with outflow against the wall and intake in the direction of the room interior
shows the best results in this simulation comparison. The visualization of the mass
concentration allows qualitative evaluations of the particle paths from the injection to
their target boundary. A column represents one particle source position and allows for a
comparison of the different locations of the air purifier in different rows in Fig. 13.
FIG. 13.
Particle concentration of different air purifier positions and particle source
positions at an ACH of 5. (a)–(d) Air purifier position SW-N with the aerosol source
positions 1, 29, 63, and 80. (e)–(h) Air purifier position SW-W. (i)–(l) Air
purifier position NE-N.
Particle concentration of different air purifier positions and particle source
positions at an ACH of 5. (a)–(d) Air purifier position SW-N with the aerosol source
positions 1, 29, 63, and 80. (e)–(h) Air purifier position SW-W. (i)–(l) Air
purifier position NE-N.
Extended case studies
As an extension of the numerical study, the flow velocity at different ACHs and the
differences in buoyancy flows in summer and winter will be investigated.
Air velocity for different ACHs
The zone of influence of the intake of the air purifier is significantly smaller than
the pressure side area. This value is exceeded at the person seats when the air purifier
operates at the highest level (see Fig. 14). At an
ACH of 5, these comfort limits are just fine in the seating areas. This level represents
the maximum performance of the room air filter in this room and this positioning without
causing discomfort to the persons due to excessive air velocities. Operation of the room
air filter at an ACH of 5 is recommended in this room to achieve the best possible
compromise between comfort due to air velocity and filter volume flow. The air purifier
has to be oriented in such a way that the outflow area is not directed toward occupied
seats. In addition, with the variation in the ACH, it can be shown that the duration of
the particle movement from the source to the air purifier decreases with a higher flow
rate. Depending on the air change rate, redirecting particles to the air purifier
reduces the possible infectious particle streams by more than 50% (see Fig. 15).
FIG. 14.
Air velocity (NE-N) at different ACHs. (a) ACH = 0, (b) ACH = 3, (c) ACH = 5, (d)
ACH = 10.
FIG. 15.
Comparison of particle fates at different ACHs.
Air velocity (NE-N) at different ACHs. (a) ACH = 0, (b) ACH = 3, (c) ACH = 5, (d)
ACH = 10.Comparison of particle fates at different ACHs.
Summer vs winter air flow
Using the incompressible ideal gas law, the air density can change due to local
temperature differences. The density differences lead to buoyancy forces. In Fig. 16, the vertical velocity (v in the positive
Y-direction) is shown. The difference of summer and winter simulation is mainly
noticeable at the window side. The cold window glass in winter leads to sinking air
flows. Directly below the window is the radiator, which causes upward flows. At the
height of the window sill, these descending and ascending streams intersect and lead to
a lateral deflection of the heating flow toward the interior of the room. However, the
area of influence of the heating flow is locally limited to about one m.
FIG. 16.
Comparison of summer (a) and winter (b) air flows near windows and radiator. (a)
Summer and (b) Winter.
Comparison of summer (a) and winter (b) air flows near windows and radiator. (a)
Summer and (b) Winter.
LIMITATIONS OF THE PRESENTED APPROACH
While the PM1 dose is used to evaluate the efficiency of the air purifier, it is unlike the
inhaled particulate matter responsible for airborne transmission. First, this is due to
inhaled particles being deposited in the lungs and therefore removed from further
circulation. However, assuming an average relaxed breathing rate of 8 L/min and lungs with a
filter efficiency of 100%, the combined CADR of 80 occupants amounts to
38.4 m3/h. Even at full occupancy, the CADR by lung deposition is negligibly
small compared to the CADR of an air purifier. Second, the actual exposure to virus-laden
droplets is far lower than the exposure measured in this study. For this reason, no direct
infection risk was calculated, but rather the relative infection risk connected to the
optimized operating parameters of the air purifier was evaluated. In real-world
applications, the HVAC system is likely to be running, influencing the distribution and
decay of the particle concentration. Furthermore, the examined cases did not include dynamic
processes, such as moving particle sources and varying source strength (through coughing,
talking, etc.). Since most air purifiers on the market today are highly distinguishable in
their design regarding the location of the intake and outlet, this is a highly specific case
from which no generalization of the observed phenomenon to all types of air purifiers can be
made. Although the low-cost particle sensors have a much lower resolution and a narrower
measurement range compared to the high-end OPCs, the validation experiments showed that the
decay rate is highly comparable to that of the latter devices. Since the high-end OPCs
measure considerably more PM1 mass concentration over the course of the experiment, the
efficiency of the air purifier was evaluated either by comparing the low-cost particle
sensor or high-end OPC data. In order to push the particle size distribution into the
measurement range of the low-cost particle sensors, the mass concentration of the saline
solution was raised from 2.5 wt. % in the first experimental setup to 16 wt. % in the
second. This raised the median particle diameter x50,0 from 0.25
to 0.34 μm. The experiments were carried out over a substantial period in
winter going into spring. The ambient conditions changed accordingly and influenced
parameters such as outside temperature and relative humidity, which will influence the
thermal convection of particle exposure throughout the room. Furthermore, the investigation
focuses on a single room and the transferability to other rooms is yet to be
investigated.The most critical point is the assumption that particle fates correlate with the infection
risk. This correlation has not been proven and is an assumption. In addition, it is assumed
that each stream has the same potential for infection. Obviously, not only the destination
of the particle streams is relevant for the infection risk. Particles can be infectious on
their path between injection and destination boundary. For this reason, the particle mass
concentration was calculated. From the experimental results, it is known that the particle
mass concentration with the build-up phase and decay phase is strongly time-dependent. The
numerical result is only available as stationary averaged values in time. Therefore, it can
only be used as a subjective evaluation criterion. A limited number of 10 000 trajectories
are calculated in the simulation, although in reality the number of particles is essentially
higher. Another aspect is differences of the numerical model from reality. First, the
geometric model is highly simplified. In addition, the real boundary conditions of the room
are difficult to detect and to transfer into the simulation boundary conditions.
CONCLUSION
In this work, we have studied the influence of the position and orientation of an air
purifier on the aerosol particle concentration in a lecture hall and identified preferable
cases with respect to a low aerosol exposure of persons present in the room. Specifically,
we have set up a PM1 sensor network consisting of 12 sensors exactly at the locations where
particles may be inhaled and included the influence of thermal buoyancy by mimicking the
effect of persons present in the room using thermal dummies. We investigated both the
charging phase where the air purifier fights against a source (the “infected person is in
the room”) and the decay phase (the “infected person has left the room”). Furthermore, we
validated a CFD model based on the measurements in order to study particle fates and to
allow for the investigation of situations, which can hardly or not be considered
experimentally. Overall, the results stress that filtration is an effective means of
reducing aerosol particle concentrations. The measurements suggest that a blowout against
the wall may be particularly advantageous in order to avoid an increase in the local
particle concentration at the locations where persons breathe after turning on the air
purifier. In turns out that the air purifier can very effectively reduce aerosol particle
concentrations in a combined loading and decay scenario by 86% using a good orientation with
the obstructed outlet and by 61% in an unfavorable orientation and position. The CFD
simulations suggest that an additional effect of risk mitigation is the fact that the air
purifier reduces the deposition of aerosol particles on critical surfaces (persons and
furniture).However, it needs to be stressed that the aerosol dose and particle fates may differ from
the actual infection risks due to system-inherent differences, such as the fact that inhaled
particles are removed in reality but remain within the system in the models and in the
experiments. Further work needs to be done to provide insight into the fact how the specific
flow configuration influences the results. Therefore, this study should be extended taking
into account different air purifier devices. In addition, it needs to be investigated to
which extend the results obtained depend on the specific geometry of the lecture hall and
how far they can be generalized.