| Literature DB >> 35028075 |
Yen-Chang Huang1, Shinn-Jyh Ding1,2, Cadmus Yuan3, Min Yan1,2.
Abstract
BACKGROUND/Entities:
Keywords: Biomechanics; Finite element analysis; Stress distribution; Tooth-implant supported prosthesis
Year: 2021 PMID: 35028075 PMCID: PMC8739742 DOI: 10.1016/j.jds.2021.07.020
Source DB: PubMed Journal: J Dent Sci ISSN: 1991-7902 Impact factor: 2.080
Figure 13D FEA model.
Figure 2TISP structure model components. PDL: periodontal ligament.
Physical properties of the materials used.
| Material | Modulus of elasticity, (MPa) | Poisson's ratio |
|---|---|---|
| Tooth solid | 18 600 | 0.31 |
| Periodontal ligament (0.25 mm) | 170 | 0.45 |
| Titanium (fixture, abutment, fixation screw) | 117 000 | 0.35 |
| Ni–Cr alloy | 204 000 | 0.30 |
| Cortical bone | 13 700 | 0.30 |
| Spongy bone | 1370 | 0.30 |
| Cement (Glass ionomer) | 16 900 | 0.30 |
Number of elements and nodes in the study.
| R1 | NR1 | R2 | NR2 | R3 | NR3 | |
|---|---|---|---|---|---|---|
| Elements | 350 320 | 402 958 | 435 043 | 481 678 | 363 793 | 480 040 |
| Nodes | 524 627 | 558 556 | 609 736 | 668 549 | 551 651 | 666 989 |
R1: rigid type with one-piece implant system; NR1: non-rigid type with one-piece implant system; R2: rigid type with two-piece implant system; NR2: non-rigid type with two-piece implant system; R3: rigid type with three-piece implant system; NR3: non-rigid type with three-piece implant system.
The average stress (MPa) of each component in axial 300 N loading force.
| R1 | NR1 | R2 | NR2 | R3 | NR3 | |
|---|---|---|---|---|---|---|
| Tooth solid | 8.69 | 8.21 | 5.36 | 3.76 | 5.10 | 3.77 |
| PDL | 6.79 | 9.99 | 9.01 | 9.10 | 3.58 | 9.08 |
| 0.4 mm Cortical bone | 8.98 | 11.69 | 11.52 | 11.66 | 6.62 | 11.63 |
| Cement1 | 2.46 | 12.13 | 5.98 | 5.15 | 6.05 | 5.16 |
| Cement3 | 11.49 | 9.02 | 10.55 | 9.31 | 9.99 | 8.41 |
| Crown1+2 | 4.74 | 8.33 | 6.39 | 7.45 | 6.27 | 7.47 |
| Crown3 | 11.86 | 11.26 | 8.43 | 8.79 | 8.73 | 8.99 |
| Cortical bone | 5.06 | 4.37 | 3.76 | 3.73 | 3.87 | 3.81 |
| Spongy bone | 0.73 | 1.20 | 1.42 | 1.22 | 1.38 | 1.24 |
| Implant fixture | 23.46 | 15.60 | 10.48 | 10.11 | 11.74 | 10.41 |
| Implant abutment | Nil | Nil | 20.34 | 24.15 | 30.51 | 25.04 |
| Fixation screw | Nil | Nil | Nil | Nil | 14.48 | 12.47 |
PDL: periodontal ligament; Cement1: cement layer for crown1; Cement3: cement layer for crown3; Crown1+2: crown1 and pontic on one end of the bridge; Crown3: crown at other end of the dental bridge; R1: rigid type with one-piece implant system; NR1: non-rigid type with one-piece implant system; R2: rigid type with two-piece implant system; NR2: non-rigid type with two-piece implant system; R3: rigid type with three-piece implant system; NR3: non-rigid type with three-piece implant system.
Figure 3(a) The average stress of prosthetic connection element components; (b) The average stress of natural tooth vertical element components. R1: rigid type with one-piece implant system; NR1: non-rigid type with one-piece implant system; R2: rigid type with two-piece implant system; NR2: non-rigid type with two-piece implant system; R3: rigid type with three-piece implant system; NR3: non-rigid type with three-piece implant system.
Figure 4Von Mises stress distribution at TISP structure components. (A) R1: Rigid type with one-piece implant system. (B) NR1: Non-rigid type with one-piece implant system. (C) R2: Rigid type with two-piece implant system. (D) NR2: Non-rigid type with two-piece implant system. (E) R3: Rigid type with three-piece implant system. (F) NR3: Non-rigid type with three-piece implant system.
The maximum von Mises stress (MPa) of each component in axial 300 N loading force.
| R1 | NR1 | R2 | NR2 | R3 | NR3 | |
|---|---|---|---|---|---|---|
| Tooth solid | 105.96 | 144.59 | 134.67 | 142.71 | 104.83 | 142.48 |
| PDL | 69.63 | 93.31 | 92.56 | 91.98 | 104.83 | 91.78 |
| 0.4 mm Cortical bone | 87.98 | 116.58 | 124.55 | 124.35 | 118.08 | 124.11 |
| Cement1 | 48.15 | 379.05 | 315.49 | 187.35 | 329.90 | 188.15 |
| Cement3 | 83.54 | 43.86 | 58.37 | 53.79 | 149.37 | 54.60 |
| Crown1+2 | 90.75 | 312.85 | 243.67 | 243.20 | 240.45 | 244.14 |
| Crown3 | 308.90 | 505.84 | 67.05 | 489.84 | 69.58 | 493.93 |
| Cortical bone | 72.84 | 64.20 | 63.06 | 56.17 | 56.43 | 41.04 |
| Spongy bone | 42.84 | 48.32 | 57.94 | 51.21 | 43.89 | 51.16 |
| Implant fixture | 159.40 | 93.50 | 267.72 | 488.40 | 396.45 | 452.36 |
| Implant abutment | Nil | Nil | 237.77 | 424.11 | 431.71 | 299.00 |
| Fixture screw | Nil | Nil | Nil | Nil | 80.97 | 124.23 |
PDL: periodontal ligament; Cement1: cement layer for crown1; Cement3: cement layer for crown3; Crown1+2: crown1 and pontic on one end of the bridge; Crown3: crown at other end of the dental bridge; R1: rigid type with one-piece implant system; NR1: non-rigid type with one-piece implant system; R2: rigid type with two-piece implant system; NR2: non-rigid type with two-piece implant system; R3: rigid type with three-piece implant system; NR3: non-rigid type with three-piece implant system.
Figure 5Von Mises stress distribution at support medium. (A) R1: Rigid type with one-piece implant system. (B) NR1: Non-rigid type with one-piece implant system. (C) R2: Rigid type with two-piece implant system. (D) NR2: Non-rigid type with two-piece implant system. (E) R3: Rigid type with three-piece implant system. (F) NR3: Non-rigid type with three-piece implant system.