Literature DB >> 35021156

An iterative image-based inter-frame motion compensation method for dynamic brain PET imaging.

Tao Sun1, Yaping Wu2, Yan Bai2, Zhenguo Wang1, Chushu Shen1, Wei Wang3, Chenwei Li3, Zhanli Hu1, Dong Liang1, Xin Liu1, Hairong Zheng1, Yongfeng Yang1, Meiyun Wang2.   

Abstract

As a non-invasive imaging tool, positron emission tomography (PET) plays an important role in brain science and disease research. Dynamic acquisition is one way of brain PET imaging. Its wide application in clinical research has often been hindered by practical challenges, such as patient involuntary movement, which could degrade both image quality and the accuracy of the quantification. This is even more obvious in scans of patients with neurodegeneration or mental disorders. Conventional motion compensation methods were either based on images or raw measured data, were shown to be able to reduce the effect of motion on the image quality. As for a dynamic PET scan, motion compensation can be challenging as tracer kinetics and relatively high noise can be present in dynamic frames. In this work, we propose an image-based inter-frame motion compensation approach specifically designed for dynamic brain PET imaging. Our method has an iterative implementation that only requires reconstructed images, based on which the inter-frame subject movement can be estimated and compensated. The method utilized tracer-specific kinetic modelling and can deal with simple and complex movement patterns. The synthesized phantom study showed that the proposed method can compensate for the simulated motion in scans with18F-FDG,18F-Fallypride and18F-AV45. Fifteen dynamic18F-FDG patient scans with motion artifacts were also processed. The quality of the recovered image was superior to the one of the non-corrected images and the corrected images with other image-based methods. The proposed method enables retrospective image quality control for dynamic brain PET imaging, hence facilitating the applications of dynamic PET in clinics and research.
© 2022 Institute of Physics and Engineering in Medicine.

Entities:  

Keywords:  dynamic PET; kinetic modelling; motion correction

Mesh:

Substances:

Year:  2022        PMID: 35021156     DOI: 10.1088/1361-6560/ac4a8f

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  1 in total

1.  Motion correction and its impact on quantification in dynamic total-body 18F-fluorodeoxyglucose PET.

Authors:  Tao Sun; Yaping Wu; Wei Wei; Fangfang Fu; Nan Meng; Hongzhao Chen; Xiaochen Li; Yan Bai; Zhenguo Wang; Jie Ding; Debin Hu; Chaojie Chen; Zhanli Hu; Dong Liang; Xin Liu; Hairong Zheng; Yongfeng Yang; Yun Zhou; Meiyun Wang
Journal:  EJNMMI Phys       Date:  2022-09-14
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.