Application of simplified regional citrate anticoagulation in hemodialysis patients with high risk of bleeding.

Wei Wang, Shaoyan Zhang, Yuehong Li, Xianglan Wu, Hua Yang, Jiaxuan Lv, Huiying Xu, Chong Wang.   

Abstract

AIM: To explore the safety, effectiveness, and dialysis adequacy of simplified regional citrate anticoagulation hemodialysis (SRCA-HD) in hemodialysis patients with high risk of bleeding.
MATERIALS AND METHODS: From 64 hemodialysis patients, 400 cases of low blood flow (150 mL/min, dialysate flow 300 mL/min) SRCA-HD were retrospectively analyzed and subsequently referred to as the LBF-SRCA group. Then, a prospective cross-over study was performed in 24 hemodialysis patients with normal blood flow (200 mL/min, dialysate flow 500 mL/min) SRCA-HD, which was called the NBF-SRCA group. Citrate was pumped at the artery pipeline, and calcium-containing dialysate (A group: 1.25 mmol/L, B group: 1.5 mmol/L) was used. The differences in laboratory tests, pipeline and dialyzer clotting, adequacy of dialysis, and adverse events of the groups were compared.
RESULTS: 1) In the LBF-SRCA study, the correlation between citrate dosage and serum Ca2+ level at 2 hours post-filter during dialysis was negative (r = -0.228, p < 0.05). Compared with the LBF-SRCA and NBF-SRCA-A group, the pump speed of citrate in the NBF-SRCA-B group was the highest, with 355.0 ± 19.5 mL/h, 396.3 ± 11.9 mL/h, and 407.7 ± 13.0 mL/h, respectively, p < 0.001. 2) The serum Ca2+ at 2 and 4 hours post-filter during dialysis in the NBF-SRCA-B group was closer to the physiological level and significantly higher than in the A group, with 0.80 ± 0.06 vs. 0.68 ± 0.12 mmol/L, p < 0.001; 1.03 ± 0.11 vs. 0.93 ± 0.10 mmol/L, p = 0.005, respectively. 3) Both Kt/V of the NBF-SRCA-A (1.17 ± 0.24) and B (1.22 ± 0.23) group were significantly higher than that of the LBF-SRCA group (0.94 ± 0.02), p = 0.024 and p = 0.005, respectively. 4) The efficiency of anticoagulation was higher than 95% LBF-SRCA, NBF-SRCA-A and NBF-SRCA-B groups. The total clotting in the NBF-SRCA-B group (5/24) was significantly higher than that in the A group (3/24), p = 0.005.
CONCLUSION: SRCA is safe, simple, and effective in hemodialysis. The dosage of citrate can be adjusted by monitoring serum Ca2+ at 2 hours post-filter during dialysis. BFR of 200 mL/min, dialysate flow rate of 500 mL/min, and 1.5 mmol/L calcium dialysate are much safer in hemodialysis patients with a high-risk of bleeding.

Entities:  

Mesh:

Substances:

Year:  2022        PMID: 35006070     DOI: 10.5414/CN110559

Source DB:  PubMed          Journal:  Clin Nephrol        ISSN: 0301-0430            Impact factor:   0.975