Literature DB >> 3500236

Quantification of C3d in biological fluids by an enzyme-linked immunosorbent assay.

M Peakman1, A Lobo-Yeo, G Senaldi, M Nilsson, D E Tee, D Vergani.   

Abstract

Using a commercial source of peroxidase-labelled anti-C3d antibody (Dakopatts), an enzyme-linked immunosorbent assay (ELISA) has been developed to quantify the complement fragment C3d. The technique enables the detection of C3d in plasma, urine and cerebrospinal fluid (CSF). The C3d-ELISA therefore provides a very sensitive technique for the evaluation of complement activation in biological fluids. In both plasma and urine the technique is able to discriminate between samples from normal controls and patients with rheumatoid arthritis in whom complement activation is known to occur. A good correlation was found between results obtained by ELISA and those by laser nephelometry (r = 0.91, P less than 0.0001). Microtitre plates pre-coated with anti-C3d antibody and subsequently stored at -70 degrees C retained the ability to perform in this assay. The sensitivity, short assay time and use of commercial reagents and pre-coated plates give this technique numerous potential applications in the evaluation of complement activation.

Entities:  

Mesh:

Substances:

Year:  1987        PMID: 3500236     DOI: 10.1016/0022-1759(87)90486-8

Source DB:  PubMed          Journal:  J Immunol Methods        ISSN: 0022-1759            Impact factor:   2.303


  6 in total

1.  C3/C4 concentration ratio reverses between colostrum and mature milk in human lactation.

Authors:  V Trégoat; P Montagne; M L Cuillière; M C Béné; G Faure
Journal:  J Clin Immunol       Date:  1999-09       Impact factor: 8.317

Review 2.  Review: assessment of complement activation in clinical immunology laboratories: time for reappraisal?

Authors:  M Peakman; G Senaldi; D Vergani
Journal:  J Clin Pathol       Date:  1989-10       Impact factor: 3.411

3.  Effect of fresh frozen plasma and gammaglobulin on humoral immunity in neonatal sepsis.

Authors:  B A Acunas; M Peakman; G Liossis; E T Davies; B Bakoleas; C Costalos; H R Gamsu; D Vergani
Journal:  Arch Dis Child Fetal Neonatal Ed       Date:  1994-05       Impact factor: 5.747

4.  Measurement of terminal complement complexes in rheumatoid arthritis.

Authors:  B P Morgan; R H Daniels; B D Williams
Journal:  Clin Exp Immunol       Date:  1988-09       Impact factor: 4.330

5.  Weak Expression of Terminal Complement in Active Antibody-Mediated Rejection of the Kidney.

Authors:  Gesa Tiller; Rosa G M Lammerts; Jessy J Karijosemito; Firas F Alkaff; Arjan Diepstra; Robert A Pol; Anita H Meter-Arkema; Marc A Seelen; Marius C van den Heuvel; Bouke G Hepkema; Mohamed R Daha; Jacob van den Born; Stefan P Berger
Journal:  Front Immunol       Date:  2022-04-13       Impact factor: 8.786

6.  Strong predictive value of mannose-binding lectin levels for cardiovascular risk of hemodialysis patients.

Authors:  Felix Poppelaars; Mariana Gaya da Costa; Stefan P Berger; Solmaz Assa; Anita H Meter-Arkema; Mohamed R Daha; Willem J van Son; Casper F M Franssen; Marc A J Seelen
Journal:  J Transl Med       Date:  2016-08-05       Impact factor: 5.531

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.