Literature DB >> 34994850

[MRI-based catheter ablation : Current status and outlook].

M Khalaph1, D Guckel2, L Bergau2, C Sohns2, C Jahnke3, I Paetsch3, P Sommer2.   

Abstract

Fluoroscopy-based catheter ablation has established itself as a standard procedure for the treatment of patients with cardiac arrhythmias. However, it is subject to certain limitations with regard to the visualization of arrhythmogenic substrate and ablation lesions and is associated with radiation exposure. Within the framework of studies, initial experience with MRI-based, radiation-free electrophysiological examinations and ablations could be gained. The integration of MRI technology into electrophysiological procedures promises numerous advantages. The ability to operate in a radiation-free environment during MRI-based catheter ablation is significant and promising. Furthermore, MRI provides important procedure-relevant information in terms of visualization of individual arrhythmogenic substrate. In order to further improve immediate and long-term ablation success, especially in the context of complex arrhythmias and structural heart disease, the direct and successful integration of MRI-generated findings into the ablation process is of utmost importance. The future of MRI-based catheter ablation could thus lie in particular in the treatment of more complex cardiac arrhythmias, which require personalized therapy paths. In this respect, however, the data situation is still extremely limited. Further technical developments and larger studies are indispensable in order to gain further important insights into the feasibility, safety and success rate of MRI-based invasive electrophysiological diagnostics and therapy in comparison to conventional ablation methods.
© 2022. The Author(s), under exclusive licence to Springer Medizin Verlag GmbH, ein Teil von Springer Nature.

Entities:  

Keywords:  Ablation; Arrhythmia substrate; Cardiac arrhythmias; Electrophysiology; Magnetic resonance imaging

Mesh:

Year:  2022        PMID: 34994850     DOI: 10.1007/s00399-021-00832-w

Source DB:  PubMed          Journal:  Herzschrittmacherther Elektrophysiol        ISSN: 0938-7412


  2 in total

1.  Appropriate timing of electrophysiological study in myotonic dystrophy type 1: unsolved question-Authors' reply.

Authors:  Carsten W Israel; Michael Glikson; Jens Cosedis Nielsen
Journal:  Europace       Date:  2022-07-15       Impact factor: 5.486

2.  Magnetic resonance imaging-compatible circular mapping catheter: an in vivo feasibility and safety study.

Authors:  Delphine Elbes; Julie Magat; Assaf Govari; Yaron Ephrath; Delphine Vieillot; Christopher Beeckler; Rukshen Weerasooriya; Pierre Jais; Bruno Quesson
Journal:  Europace       Date:  2017-03-01       Impact factor: 5.214