Literature DB >> 34993554

Atlantoaxial posterior screw fixation using intra-operative spinal navigation with three-dimensional isocentric C-arm fluoroscopy.

Gianpaolo Jannelli1, Alessandro Moiraghi1,2,3, Luca Paun4, Victor Cuvinciuc5, Andrea Bartoli1, Enrico Tessitore1.   

Abstract

PURPOSE: Intra-operative image acquisition coupled with navigation aims to increase screw placement accuracy, and it is particularly helpful in complex spinal procedures. The aim of this study is to analyze the accuracy and reliability of posterior atlanto-axial fixation using spinal navigation combined with intra-operative 3D isocentric C-arm.
METHODS: We retrospectively reviewed all patients presenting with C1-C2 instability and treated by posterior atlanto-axial fixation in our center between December 2016 and September 2018. Screw positioning was guided by intra-operative navigation, registered with surface matching procedure on a previously obtained CT scan and controlled by intra-operative 3D isocentric C-arm. Age, sex, pre- and post-operative neurological status, duration of surgery, presence/absence of vertebral artery injury, and screw placement were retrospectively collected from patients' records. All patients underwent clinical and radiological follow-up at three months after surgery. Radiological assessment of screw positioning was performed by an independent radiologist using the Gertzbein and Robbins grading.
RESULTS: N = 11 (7F, 4 M) consecutive patients were included, with a mean age of 72 years (range from 51 to 85). N = 44 navigated screws were inserted and controlled with intra-operative 3D fluoroscopy at the end of the procedure. An acceptable screw positioning (Gertzbein-Robbins grade A and B) was obtained in all cases (100%). No vertebral artery injury was observed. Mean operating time was 123 minutes. At three months, no screw loosening or displacement was observed.
CONCLUSION: In our experience, spinal navigation coupled with intra-operative 3D fluoroscopy proved to be reliable and safe for C1-C2 screw placement.
© 2021. The Author(s) under exclusive licence to SICOT aisbl.

Entities:  

Keywords:  3D fluoroscopy; Atlantoaxial instability; C1–C2 fixation; Navigation; Screw placement; Vertebral artery injury

Mesh:

Year:  2022        PMID: 34993554     DOI: 10.1007/s00264-021-05276-y

Source DB:  PubMed          Journal:  Int Orthop        ISSN: 0341-2695            Impact factor:   3.075


  16 in total

1.  Fixation strength of unicortical versus bicortical C1-C2 transarticular screws.

Authors:  Steven J Cyr; Bradford L Currier; Jason C Eck; Andrew Foy; Qingshan Chen; Dirk R Larson; Michael J Yaszemski; Kai-Nan An
Journal:  Spine J       Date:  2007-05-11       Impact factor: 4.166

2.  Biomechanical comparison of unicortical versus bicortical C1 lateral mass screw fixation.

Authors:  Jason C Eck; Matt P Walker; Bradford L Currier; Qingshan Chen; Michael J Yaszemski; Kai-Nan An
Journal:  J Spinal Disord Tech       Date:  2007-10

3.  The biomechanical influence of the facet joint orientation and the facet tropism in the lumbar spine.

Authors:  Ho-Joong Kim; Heoung-Jae Chun; Hwan-Mo Lee; Kyoung-Tak Kang; Choon-Ki Lee; Bong-Soon Chang; Jin S Yeom
Journal:  Spine J       Date:  2013-09-12       Impact factor: 4.166

Review 4.  Endodermal cysts of the posterior fossa. Report of three cases and review of the literature.

Authors:  G K Bejjani; D C Wright; D Schessel; L N Sekhar
Journal:  J Neurosurg       Date:  1998-08       Impact factor: 5.115

5.  The accuracy of 3D fluoroscopy-navigated screw insertion in the upper and subaxial cervical spine.

Authors:  J Bredow; J Oppermann; B Kraus; P Schiller; G Schiffer; R Sobottke; P Eysel; T Koy
Journal:  Eur Spine J       Date:  2015-04-30       Impact factor: 3.134

6.  When does intraoperative 3D-imaging play a role in transpedicular C2 screw placement?

Authors:  Cornelius Jacobs; Philip P Roessler; Sebastian Scheidt; Milena M Plöger; Collin Jacobs; Alexander C Disch; Klaus D Schaser; Tony Hartwig
Journal:  Injury       Date:  2017-09-08       Impact factor: 2.586

Review 7.  Atlantoaxial fixation: overview of all techniques.

Authors:  Praveen V Mummaneni; Regis W Haid
Journal:  Neurol India       Date:  2005-12       Impact factor: 2.117

8.  Spinal navigation for posterior instrumentation of C1-2 instability using a mobile intraoperative CT scanner.

Authors:  Marcus Czabanka; Julien Haemmerli; Nils Hecht; Bettina Foehre; Klaus Arden; Thomas Liebig; Johannes Woitzik; Peter Vajkoczy
Journal:  J Neurosurg Spine       Date:  2017-06-09

9.  Primary posterior fusion C1/2 in odontoid fractures: indications, technique, and results of transarticular screw fixation.

Authors:  B Jeanneret; F Magerl
Journal:  J Spinal Disord       Date:  1992-12

10.  Management of occipitocervical junction and upper cervical trauma.

Authors:  Ahmet Dagtekin; Emel Avci; Vural Hamzaoglu; Hakan Ozalp; Derya Karatas; Kaan Esen; Celal Bagdatoglu; Mustafa K Baskaya
Journal:  J Craniovertebr Junction Spine       Date:  2018 Jul-Sep
View more