Literature DB >> 34992432

Different Continuous Positive Airway Pressure Titration Modalities in Obstructive Sleep Apnea Syndrome Patients.

Hadeer Ahmed Elshahaat1, Tarek Abd El-Hakeem Mahfouz1, Ashraf Elsyed Elshora1, Amany Shaker1.   

Abstract

BACKGROUND: Patients with obstructive sleep apnea syndrome are mainly treated with continuous positive airway pressure. Polysomnography-guided full-night manual titration is the gold standard for continuous positive airway pressure titration, but it is cost-, time-, and effort-consuming. Alternative ways of titration are easier with less cost, time, and effort. In the era of the COVID-19 pandemic, the need to establish more safe strategies is increased. AIM: To choose a rapid, efficient, simple, and safe method with less effort and cost in the measurement of a suitable level of positive airway pressure in the management of obstructive sleep apnea syndrome.
METHODS: This study enrolled 48 adult patients who had been diagnosed with obstructive sleep apnea syndrome at our sleep unit and were candidates for treatment with continuous positive airway pressure according to AASM 2008 after exclusion of other sleep-related breathing disorders. All patients underwent both laboratory full-night manual titration and auto-titration (by Prisma20A of WEINMANN medical technology, Germany). Manual titration pressure and P95 of auto-titration were obtained and compared with calculated pressures by five predictive formulas (Miljeteig and Hoffstein, Sériès, Stradling, Loredo, and Lee).
RESULTS: Patients included in the study were 25 females (52.1%) and 23 males (47.9%) with a mean±SD of age of 49.98±10.36 years. Mean±SD of manual pressure was 10.44±2.49 cmH2O, P95 was 10.16±2.64 cmH2O, and calculated pressures by different equations were: Miljeteig and Hoffstein, 8.53±2.03; Sériès, 11.40±1.81; Stradling, 9.68±1.65; Loredo, 9.90±1.79; and Lee, 10.61±2.68 cmH2O. No significant differences were reported between manual pressure and pressures of auto-titration with Sériès, Stradling, Loredo, and Lee equations (p=0.112, 0.09, 0.212, 0.213, and 0.657, respectively).
CONCLUSION: Auto-titration can be used as an effective alternative to manual titration with less cost and effort and is more comfortable to patients. Predictive formulas can be used instead of standard and auto-titration especially in resource-limited facilities and in pandemics.
© 2021 Elshahaat et al.

Entities:  

Keywords:  auto-titration; continuous positive airway pressure; manual titration; obstructive sleep apnea syndrome; predictive formulas

Year:  2021        PMID: 34992432      PMCID: PMC8711245          DOI: 10.2147/IJGM.S344217

Source DB:  PubMed          Journal:  Int J Gen Med        ISSN: 1178-7074


  34 in total

1.  Predictive equations for CPAP titration in OSAS patients.

Authors:  Donato Lacedonia; Roberto Sabato; Giovanna E Carpagnano; Pierluigi Carratù; Antonio Falcone; Felice Gadaleta; Onofrio Resta; Maria P Foschino Barbaro
Journal:  Sleep Breath       Date:  2011-01-06       Impact factor: 2.816

2.  The new procedure for manual CPAP titration : the afternoon CPAP titration (aPT).

Authors:  Keisuke Kido; Naoko Tachibana
Journal:  J Med Invest       Date:  2021

3.  Comparison of manual versus automatic continuous positive airway pressure titration and the development of a predictive equation for therapeutic continuous positive airway pressure in Chinese patients with obstructive sleep apnoea.

Authors:  Jiaying Luo; Sichang Xiao; Zhihui Qiu; Ning Song; Yuanming Luo
Journal:  Respirology       Date:  2013-04       Impact factor: 6.424

4.  Is automatic CPAP titration as effective as manual CPAP titration in OSAHS patients? A meta-analysis.

Authors:  Weijie Gao; Yinghui Jin; Yan Wang; Mei Sun; Baoyuan Chen; Ning Zhou; Yuan Deng
Journal:  Sleep Breath       Date:  2011-02-24       Impact factor: 2.816

5.  Automatic pressure titration with APAP is as effective as manual titration with CPAP in patients with obstructive sleep apnea.

Authors:  Ingo Fietze; Martin Glos; Isabel Moebus; Christian Witt; Thomas Penzel; Gert Baumann
Journal:  Respiration       Date:  2007-02-23       Impact factor: 3.580

Review 6.  Prediction of continuous positive airway pressure in obstructive sleep apnea.

Authors:  José S Loredo; Charles Berry; Richard A Nelesen; Joel E Dimsdale
Journal:  Sleep Breath       Date:  2007-03       Impact factor: 2.816

7.  Predicting effective continuous positive airway pressure in Taiwanese patients with obstructive sleep apnea syndrome.

Authors:  I-Feng Lin; Ming-Lung Chuang; Yu-Fang Liao; Ning-Hung Chen; Hsueh-Yu Li
Journal:  J Formos Med Assoc       Date:  2003-04       Impact factor: 3.282

8.  Relative accuracy of algorithm-based prescription of nasal CPAP in OSA.

Authors:  J R Stradling; M Hardinge; J Paxton; D M Smith
Journal:  Respir Med       Date:  2004-02       Impact factor: 3.415

9.  Automatic titration and calculation by predictive equations for the determination of therapeutic continuous positive airway pressure for obstructive sleep apnea.

Authors:  Oreste Marrone; Adriana Salvaggio; Salvatore Romano; Giuseppe Insalaco
Journal:  Chest       Date:  2008-03       Impact factor: 9.410

10.  Determinants of continuous positive airway pressure level for treatment of obstructive sleep apnea.

Authors:  H Miljeteig; V Hoffstein
Journal:  Am Rev Respir Dis       Date:  1993-06
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.