Literature DB >> 34990494

Reproducibility of knee extensor and flexor contraction velocity in healthy men and women assessed using tensiomyography: A study protocol.

Georg Langen1,2, Christine Lohr3, Olaf Ueberschär4,5, Michael Behringer1.   

Abstract

Tensiomyography measures the radial displacement of a muscle during an electrically evoked twitch contraction. The rate of muscle displacement is increasingly reported to assess contractile properties. Several formulas currently exist to calculate the rate of displacement during the contraction phase of the maximal twitch response. However, information on the reproducibility of these formulas is scarce. Further, different rest intervals ranging from 10 s to 30 s are applied between consecutive stimuli during progressive electrical stimulation until the maximum twitch response. The effect of different rest intervals on the rate of displacement has not been investigated so far. The first aim of this study is to investigate the within and between-day reliability of the most frequently used formulas to calculate the rate of displacement. The second aim is to investigate the effect of changing the inter-stimulus interval on the rate of displacement. We will determine the rectus femoris and biceps femoris rate of displacement of twenty-four healthy subjects' dominant leg on two consecutive days. The maximum displacement curve will be determined two times within three minutes on the first day and a third time 24 h later. On day two, we will also apply three blocks of ten consecutive stimuli at a constant intensity of 50 mA. Inter-stimuli intervals will be 10 s, 20 s or 30 s in each block, respectively, and three minutes between blocks. The order of inter-stimulus intervals will be randomized. This study will allow a direct comparison between the five most frequently used formulas to calculate the rate of displacement in terms of their reproducibility. Our data will also inform on the effect of different inter-stimulus intervals on the rate of displacement. These results will provide helpful information on methodical considerations to determine the rate of displacement and may thus contribute to a standardized approach.

Entities:  

Mesh:

Year:  2022        PMID: 34990494      PMCID: PMC8735606          DOI: 10.1371/journal.pone.0262156

Source DB:  PubMed          Journal:  PLoS One        ISSN: 1932-6203            Impact factor:   3.240


Introduction

A muscle twitch is the contractile response to a single electrochemical signal of the nervous system or artificial electrical stimulation of the muscle. As such, a twitch provides information on muscle contractile properties and the functioning of the excitation-contraction coupling process. Tensiomyography (TMG) measures the radial displacement of a muscle belly during an electrically stimulated isometric twitch response. From the radial displacement curve, spatial and temporal parameters are derived. The two most frequently reported parameters are the maximum displacement (Dm) and the contraction time (Tc) [1]. Dm provides information on skeletal muscle stiffness, morphological and structural changes [2-4]. Tc refers to the time interval between 10% and 90% of Dm and is correlated to the proportion of slow-twitch fibres [5-7]. Therefore, a shorter Tc is commonly associated with a higher contraction velocity [8-11]. TMG is an involuntary method that does not require any effort from the subject. Therefore it is frequently used to assess muscular function following fatiguing exercise [12-16] or the effectiveness of different recovery strategies [17-20]. Muscular fatigue causes a slowing of muscle contraction velocity, reversing as the muscle recovers from fatigue [21-24]. Consequently, an increase in Tc of a fatigued muscle which is reversed as the muscle recovers is expected. However, previous studies found no change [14] or even a decrease of Tc [16, 25] after fatiguing exercise. Several authors pointed out that changes in Dm inevitably lead to changes in Tc [25, 26]. Accordingly, changes in Tc should not be interpreted independently of changes in Dm. As a result, an increasing number of studies reports the rate of displacement (Vc), i.e. the slope of the radial displacement-time curve. Several different formulas exist to calculate Vc but no consensus exists on the most suitable formula. Further, there is a lack of studies investigating the reproducibility of these formulas, as only two studies investigated the reliability of Vc so far. Lohr et al. [27] investigated the within and between-day reliability of Vc in the lumbar erector spinae muscle of healthy females and males, using this formula: Vc = 0.8*Dm / Tc. Vc in this study showed an excellent relative (intraclass correlation coefficient ICC > 0.90) and absolute (coefficient of variation CV < 8%) reliability. De Paula Simola et al. [28] investigated the between-day reliability of the following two formulas to calculate Vc in twenty male sports students: V10 = 0.1*Dm / t10% and V90 = 0.9*Dm / t90% [28]. Absolute reliability was higher in rectus femoris (RF) and biceps femoris (BF) (CV < 10%) compared to gastrocnemius lateralis (CV = 12.3% and CV = 11.3% for V10 and V90, respectively) [28]. Both formulas showed excellent relative reliability in all three muscles (ICC > 0.90) [28]. In addition to the formulas used in the two studies mentioned, two other formulas to calculate Vc have been frequently reported: Vc = Dm / (Td +Tc) [29] and Vcrn = 0.8 / Tc [30]. The reproducibility of Vc calculated by these two formulas is still unclear. Therefore, information on the reproducibility of these two formulas is needed. Further, a direct comparison of all five formulas for calculating Vc in terms of their reproducibility within the same sample would help reach a consensus on a standardized approach. Differences exist not only regarding the formulas used to calculate Vc, but also regarding the electrical stimulation procedure to determine the radial displacement curve from which Vc is calculated. In a systematic review about the reliability of TMG, Martín-Rodríguez et al. [1] found that previous studies mainly used an inter-stimulus interval (ISI) of 10 s or 15 s to avoid fatigue or post-tetanic potentiation. But they also stated a lack of studies investigating the optimal rest interval between consecutive stimuli [1]. To our knowledge, only two studies investigated the effect of different ISI on tensiomyographic parameters so far. One study investigated the effect of different ISI (30 s, 10 s, 5 s) on Dm and Tc of the RF muscle during ten consecutive stimuli at a constant intensity (50 mA) [31]. The results showed that Tc was not significantly affected by different ISI, whereas Dm was significantly greater using an ISI of 10 s than 30 s [31]. Notably, Tc decreased significantly during ten consecutive stimuli, irrespective of the ISI, whereas Dm was not affected [31]. However, Latella et al. [32] found no significant effect of ISI (10 s, 20 s) on Dm or Tc of the biceps brachii muscle. Consequently, they concluded that an ISI of 10 s is sufficient during five consecutive stimuli [32]. However, both of the studies mentioned above did not report Vc, so the effect of ISI during repeated stimulation on Vc is still unclear. Therefore, the first aim of this study will be to investigate the within and between-day reliability of five different formulas to calculate Vc. The second aim will be to investigate the effect of different ISI during repeated stimulation on Vc, assessed by the example of M. biceps femoris and M. rectus femoris. We hypothesize that Vc will be affected by changing ISI during ten repeated stimuli at a constant intensity of 50 mA.

Materials and methods

Study design

This study will be a single group reliability study with repeated measurements within two consecutive days. The design of this study follows the recommendations for conducting and reporting diagnostic reliability studies provided in the quality appraisal of reliability studies (QAREL) checklist [33] and the guidelines for sex and gender equity in research (SAGER) [34].

Ethical approval, registration and data availability

This study will be conducted in accordance with the Declaration of Helsinki [35]. The Ethics Committee of the Institute of Applied Training Sciences has approved this study (reference number: ER_2021.29.03_2). Eligible participants will be informed about all relevant aspects of this study and asked for their written consent before their enrolment. Upon in principle acceptance from the journal and before starting the recruitment and data collection, this study protocol will be preregistered. The preregistration including the accepted study protocol and supporting information will be openly available on the Open Science Framework platform at https://osf.io/4du2j/?view_only=ee7a4afb30514cb9a2e15381282dcec8. Once we finished the data collection and analysis, our data and the analysis code will be also openly available on this platform.

Participants and setting

This study will be conducted at the Institute for Applied Training Science. We will include 24 women and men in this study, who will be required to meet the following inclusion criteria: healthy, aged between 18–40 years, physically active for a minimum of three times per week. In addition, we will describe the subjects’ physical activity level based on data collected using the short form of the International Physical Activity Questionnaire (IPAC-SF) [36]. Exclusion criteria will be the following: pregnancy, history of neuromuscular or musculoskeletal disorders, pain or injury in the lower limbs during the last six months, previous surgical treatment to the lower limbs, practising a specific sport on a professional level, taking prescribed medication, nontolerance or any contraindication to electrical stimulation using self-adhesive electrodes, and wearing an implantable medical device. Participants will be recruited from scientific staff and students from the Institute for Applied Training Science and the Sport Sciences Department of the University of Leipzig. To this end, we will promote the study through email distribution lists, flyers and word of mouth. Potential participants will receive an informal invitation.

Experimental approach

We will determine the absolute and relative within- and between-day reliability of the five most frequently used formulas to calculate the rate of displacement of the RF and BF assessed via TMG. The RF and BF were selected as they are the most frequently investigated muscles within studies reporting Vc. We will also determine the effect of three different rest intervals between ten consecutive stimuli at a constant intensity on the rate of displacement. The number of stimuli is consistent with a previous study which showed that Tc decreased significantly with ten stimuli [31], and which served as the reference for our sample size calculation. Fig 1 schematically illustrates the study flow.
Fig 1

Schematic illustration of the study flow.

M1, M2, M3: Measurement time points 1,2,3, respectively, mA: Milliampere, ISI: Inter-stimuli interval.

Schematic illustration of the study flow.

M1, M2, M3: Measurement time points 1,2,3, respectively, mA: Milliampere, ISI: Inter-stimuli interval. A single rater with more than three years of experience performing TMG measurements will perform all tensiomyographic measurements across two consecutive days. The individual maximum radial displacement curve of both the RF and BF will be determined two times on the first day (M1, M2), separated by a three-minute pause, and a third time on the second day (M3), 24 h after the first measurement. On the second day and three minutes after the third measurement, we will apply three blocks of ten consecutive stimuli each. The rest intervals between consecutive stimuli in each block will be 10 s, 20 s and 30 s, respectively. The rest period between block 1, block 2 and block 3 will be three minutes, respectively. We will randomize the order of the three blocks with the different ISI for each participant. On the first day, we will familiarize all participants with the electrical stimulation procedure by applying two stimuli with a duration of 1 ms each at 20 mA and 30 mA to the RF, followed by a three-minute rest before starting the actual measurement [31]. All measurements will be taken at the same time of the day, and a constant room temperature of 21° C. Participants will be asked to refrain from caffeine intake for 2 h preceding all measurements [37] and to avoid alcohol consumption and fatiguing exercise for 24 h before the start and during the trial to counteract possible confounding. Further, participants will be asked to record their total dietary intake during the 24 h before the first appointment and replicate their intake during the 24 h before the second visit [26] (S1 Appendix).

Randomization and blinding

We will use an online program [38] and a block randomization procedure with four blocks of six unique numbers [39] to determine the order of ISI during repeated stimulations for each participant. To blind the rater from previous measurements, we will choose the settings of the TMG measurement software as not to display prior measurements.

Sample size justification

Two different calculations were made to justify the sample size for this study. First, a precision-based calculation for the ICC of Vc was based on previous reliability studies [27, 28]. For this calculation, we used RStudio, Version 1.3.959 and the "Nest"-function from the "ICC" package version 2.3.0 [40]. Assuming the lowest ICC reported of 0.92 [28], two measurements per subject and an alpha level of 0.05, we will need 18 subjects to achieve the desired precision with a confidence interval of 0.15. Second, to estimate how many subjects we will need to detect an effect of changing the interstimulus-interval on Vc, we used the raw data provided by Wilson et al. [31]. From those data, we calculated Vc10-90% = 0.8 Dm / Tc and Vcnorm = 0.8 / Tc (S1 Table). As only Dm and Tc were included in those raw data, we could not apply the other three formulas. We performed a two-way (ISI x measure) repeated measures analysis of variance (ANOVA) to estimate the main effect of inter-stimulus interval on Vc10-90% and Vcnorm. We obtained effect sizes using RStudio and the "eta2_to_f"-function from the "effectsize" package [41] and calculated the sample size using the "wp.rmanova"-function from the "WebPower"-package [42]. For the sample size calculation, we assumed three groups, ten measurements per subject, an effect size f = 3.1 (Vc10-90%) and f = 1.6 (Vcnorm), a nonsphericity correction coefficient of 0.7 (Vc10-90%) and 0.6 (Vcnorm), an alpha level of 0.01, a power of 0.95 and a between effect, a total of 9 (Vc10-90%) subjects and 18 (Vcnorm) subjects were needed. We confirmed the estimated sample size for the ANOVA by repeating the calculations for both Vc10-90% and Vcnorm using g*power v3.1.9.2 [43]. Based on the results of both calculations for the ICC and the ANOVA and accounting for potential dropouts, we intend to recruit 24 subjects.

Experimental set-up and procedures

To perform tensiomyographic measurements, we will use a TMG-S1 electrical stimulator (TMG-BMC d.o.o., Ljubljana, Slovenia), a GD30 displacement sensor (Panoptik d.o.o., Ljubljana, Slovenia) and two squared self-adhesive electrodes (50x50 mm, Axion GmbH, Leonberg, Germany). The signal of the displacement sensor will be recorded using the TMG Software v3.6 (TMG-BMC d.o.o., Ljubljana, Slovenia). All measurements will be performed on the RF and BF of the dominant leg. The dominant leg will be the leg that subjects reportedly would use to shoot a ball on a target [44]. The RF measurements will be performed with subjects lying in a supine position, with their arms rested aside and the knee supported at an angle of approximately 120° by a triangular foam pad provided by the manufacturer [31]. The BF measurements will be performed with subjects lying in a prone position, with their arms rested aside and the ankle supported by a semicircular foam pad, creating a knee angle of approximately 175° flexion [28]. For both muscles, 180° corresponds to full knee extension, respectively. The skin in the area of measurement will be cleaned with alcohol-soaked gauze before the positioning of the sensor and the electrodes. The position of the sensor will be determined in three steps: First, the midpoint on a line between the superior border of the patella and the anterior superior iliac spine for the RF and the BF, the midpoint on a line between the fibula head and ischial tuberosity will be determined, according to [45]. Second, the thickest part of the muscle belly in the area of the point determined during the first step will be identified by inspection and palpation during a voluntary contraction. Third, if necessary, the sensor position will be adjusted at the beginning of the progressive stimulation to obtain the highest radial displacement [26, 27]. Once the position of the sensor is identified, we will place the electrodes at a distance of 7 cm from each other, measured between the facing edges of the two electrodes, and a distance of 3.5 cm between the sensor and the proximal and distal electrodes, respectively [46]. The position of the sensor and electrodes will be marked using a dermatological pen to ensure consistent positioning during this study. The electrical stimulation will consist of single, monophasic, square wave stimuli with a duration of 1 ms each to elicit single isometric twitches. The stimulation will start at an initial stimulation amplitude of 30 mA, and will be then increased in steps of 10 mA. During M1, M2 and M3, we will apply progressive electrical stimuli with rest-intervals of 15 s between consecutive stimuli to obtain the individual maximal displacement. The stimulation amplitude will be increased until there is no further increase of the maximum radial displacement or until the stimulator’s maximum output (110 mA) is reached. During the three blocks of repeated stimulation at 50 mA on the second day, the rest intervals between consecutive stimuli will be 10 s, 20 s and 30 s, respectively. From M1, M2 and M3, the two displacement curves with the highest radial displacement of each measurement will be averaged respectively and used for further analysis. From block 1, block 2 and block 3, we will use every single displacement curve for further analysis.

Rate of displacement calculation formulas

Fig 2 illustrates three generic tensiomyographic parameters and the five different approaches to calculate Vc from the displacement curve. The TMG software will automatically calculate the following parameters (Fig 2A): maximum radial displacement (Dm, mm), delay time, which refers to the time interval between the stimulus and 10% of Dm (Td, ms) and contraction time, which refers to the time interval between 10% and 90% of Dm (Tc, ms).
Fig 2

Typical displacement curve during the twitch contraction phase until maximum displacement and tensiomyographic parameters.

(A) Three generic tensiomyographic parameters: maximum radial displacement (Dm), Delay time (Td), Contraction time (Tc). (B) Mean rate of displacement from electrical stimulus until 10% of Dm (Vc0-10%), mean rate of displacement from electrical stimulus until 90% of Dm (Vc0-90%) and mean rate of displacement between 10% and 90% of Dm (Vc10-90%).

Typical displacement curve during the twitch contraction phase until maximum displacement and tensiomyographic parameters.

(A) Three generic tensiomyographic parameters: maximum radial displacement (Dm), Delay time (Td), Contraction time (Tc). (B) Mean rate of displacement from electrical stimulus until 10% of Dm (Vc0-10%), mean rate of displacement from electrical stimulus until 90% of Dm (Vc0-90%) and mean rate of displacement between 10% and 90% of Dm (Vc10-90%). From these data, we will calculate (1) the mean rate of displacement during the time interval between the electrical stimulus until 10% of Dm as Vc0-10% = 0.1 * Dm / Td (mm/s) [17] (Fig 2B), (2) the mean rate of displacement during the time interval between the electrical stimulus until 90% of Dm as Vc0-90% = 0.9 * Dm / (Td + Tc) (mm/s) [25] (Fig 2B), (3) the mean rate of displacement during 10% and 90% of Dm as Vc10-90% = 0.8 * Dm / Tc (mm/s) [17] (Fig 2B), (4) the normalized rate of displacement by dividing the mean rate of displacement during 10% and 90% of Dm by Dm as Vcnorm = 0.8 / Tc (1/s) [30] and (5) the ratio of Dm and the time interval from the stimulus until 90% of Dm as VcDm/t90% = Dm / (Td + Tc) (mm/s) [29] (Fig 2A).

Statistical analysis

We will report Vc0-10%, Vc0-90%, Vc10-90%, Vcnorm and VcDm/t90% for both the RF and BF descriptively as mean (M) and standard deviation (SD). All data will be checked for outliers via visual inspection of boxplots. Outliers will be defined as data points outside of three times the interquartile range. The normal distribution of all variables will be tested using the Shapiro-Wilk Test. To assess a systematic bias between M1-M2 and M1-M3, we will perform a two-tailed paired t-test, respectively [47]. For the assessment of relative reliability, we will calculate intra-class correlation coefficients (ICC, mean rating (k = 2), absolute agreement, two-way mixed-effects model) with 95% confidence intervals (CI) [48]. ICC scores lower than 0.5, between 0.5 and 0.75, between 0.75 and 0.9 or greater than 0.9 will be interpreted as poor, moderate, good or excellent reliability [48]. Absolute reliability will be quantified by calculating the standard error of measurement (SEM and SEM%), the minimal detectable change (MDC and MDC%) [49] and the CV [47], including the respective 95% CI’s. The SEM indicates the estimation precision of a measure and will be calculated as SEM = SD * √1-ICC [47]. The SEM% allows a comparison of different Vc calculations as it is unitless and will be calculated as SEM% = (SEM / M)* 100 [50]. The MDC presents the smallest difference between two measures that can be differentiated from measurement error and hence may be considered real [49]. Following Weir et al. [49], we will calculate the MDC as MDC = SEM * 1.96 * √2. The MDC% will be calculated as MDC% = (MDC/M) * 100 [50] to allow a comparison between different calculations of Vc independently of units. The CV will be calculated as CV = SD / M * 100 [47], whereby SD refers to the standard deviation and M to the mean of individual differences between M1 and M2 or M1 and M3. A CV > 10% will be interpreted as insufficient reliability with reference to previous studies investigating the reliability of tensiomyographic parameters [27, 51, 52]. To assess the effects of different ISI on Vc during repeated stimulation, we will employ a within-subject repeated-measures ANOVA. The two independent variables will be ISI (10 s, 20 s, 30 s) and stimulus number (stimulus 1 to stimulus 10). The dependent variables will be Vc0-10%, Vc0-90%, Vc10-90%, Vcnorm and VcDm/t90% for both the RF and BF, respectively. Pairwise comparisons with Bonferroni correction will applied for significant main effects. The effect size Cohen’s d will be calculated as d = Mdiff / √SD1 + SD2 / 2 [53] for pairwise comparisons to allow comparisons between effects of different ISI and between consecutive stimuli. Thresholds for small, moderate, large, very large or extremely large effects will be 0.2, 0.6, 1.2, 2.0 and 4.0 [54]. Statistical significance will be set at alpha ≤ 0.05. Missing data will be handled by listwise deletion of cases with missing data [55]. All statistical analyses will be performed using R studio and respective packages. Upon completion of the data collection and analysis, the raw data disaggregated by sex and the analysis code will be openly available at https://osf.io/4du2j/?view_only=ee7a4afb30514cb9a2e15381282dcec8.

Discussion

This study will compare the five most frequently used formulas to calculate Vc regarding their within and between-day reliability, assessed by the example of M. biceps femoris and M. rectus femoris. This study will also investigate the effect of different ISI during repeated stimulation on Vc of the same muscles. To our knowledge, only two studies have investigated the reproducibility of Vc so far. Lohr et al. [27] investigated the within and between-day reliability of Vc10-90% in the lumbar erector spinae muscle of healthy females and males. Vc10-90% in this study showed an excellent relative (ICC > 0.90) and absolute (CV < 8%) reliability. De Paula Simola et a. [28] investigated the between-day reliability of Vc10% and Vc90% in the rectus femoris, biceps femoris, and gastrocnemius lateralis of male sports students. Vc10% and Vc90% both showed excellent relative reliability in all three muscles (ICC > 0.90) [28]. Absolute reliability was higher in rectus femoris and biceps femoris (CV < 10%) compared to gastrocnemius lateralis (CV = 12.3% and CV = 11.3% for V10 and V90, respectively) [28]. Our study will add to these results by contributing information on the within and between-day reliability of the five most frequently used formulas to calculate Vc. Thereby our results will allow a direct comparison between these formulas in terms of their reproducibility. Further, information on the optimal rest interval between consecutive stimuli during progressive electrical stimulation is lacking. Again, only two studies have investigated the effect of different ISI on tensiomyographic parameters [31, 32]. One study investigated the effect of different ISI (30 s, 10 s, 5 s) on Dm and Tc of the rectus femoris muscle during ten consecutive stimuli [31]. The results showed that Tc was not significantly affected by different ISI, whereas Dm was significantly greater using an ISI of 10 s than 30 s [31]. Notably, Tc decreased significantly during ten consecutive stimuli, irrespective of the ISI, whereas Dm was not affected [31]. These findings are relevant for assessing the muscle contraction velocity using Vc. An increase in Vc can be expected, if Dm increases while Tc remains unchanged as a higher displacement amplitude is achieved within the same time. Similarly, an increase in Vc can be also expected, if Tc shortens while Dm remains unchanged, as the same displacement amplitude is achieved within a shorter time. According to Wilson et al. [31], these changes in Dm and Tc during repeated stimulation may be explained by a potentiation effect. Indeed, repeated low-frequency electrical stimulation can induce post-tetanic potentiation [56], which leads to increased peak force, decreased time to peak force and increased rate of force development during an electrically evoked twitch [57]. Thus, it is conceivable that such a potentiation effect could also lead to an increase in Vc. In contrast, Latella et al. [32] found no significant effect of ISI (10 s, 20 s) on Dm or Tc of the biceps brachii muscle, measured across three different joint angles and two days. Consequently, they concluded that an ISI of 10 s is sufficient during five consecutive stimuli to avoid the effects of fatigue or potentiation. However, both studies did not report Vc, so the effect of ISI during repeated stimulation on Vc is still unclear. Therefore, our results will contribute relevant information on methodical considerations for the determination of Vc using TMG. A certain limitation of our study is that we will only assess two different muscles of the lower extremities. In the future, the reproducibility of Vc and the effect of changing ISI on Vc should therefore be investigated in a broad range of muscles, including muscles of the upper extremities. Another limitation of our study is that we will include only healthy and physically active women and men between 18 and 40. The effect of different ISI on Vc might differ in older subjects or athletes due to age- and training-related shifts in the muscle fibre spectrum [11, 58, 59].

24 h dietary intake protocol template.

(PDF) Click here for additional data file.

Calculated rate of displacement data used for sample size estimation.

(XLSX) Click here for additional data file. 20 Nov 2021 PONE-D-21-24120Reproducibility of knee extensor and flexor contraction velocity in healthy men and women assessed using tensiomyography: A study protocolPLOS ONE Dear Dr. Langen, Thank you for submitting your manuscript to PLOS ONE. After careful consideration, we feel that it has merit but does not fully meet PLOS ONE’s publication criteria as it currently stands. Therefore, we invite you to submit a revised version of the manuscript that addresses the points raised during the review process. Please submit your revised manuscript by Dec 06 2021 11:59PM. If you will need more time than this to complete your revisions, please reply to this message or contact the journal office at plosone@plos.org. When you're ready to submit your revision, log on to https://www.editorialmanager.com/pone/ and select the 'Submissions Needing Revision' folder to locate your manuscript file. Please include the following items when submitting your revised manuscript: A rebuttal letter that responds to each point raised by the academic editor and reviewer(s). You should upload this letter as a separate file labeled 'Response to Reviewers'. A marked-up copy of your manuscript that highlights changes made to the original version. You should upload this as a separate file labeled 'Revised Manuscript with Track Changes'. An unmarked version of your revised paper without tracked changes. You should upload this as a separate file labeled 'Manuscript'. If you would like to make changes to your financial disclosure, please include your updated statement in your cover letter. Guidelines for resubmitting your figure files are available below the reviewer comments at the end of this letter. If applicable, we recommend that you deposit your laboratory protocols in protocols.io to enhance the reproducibility of your results. Protocols.io assigns your protocol its own identifier (DOI) so that it can be cited independently in the future. For instructions see: https://journals.plos.org/plosone/s/submission-guidelines#loc-laboratory-protocols. Additionally, PLOS ONE offers an option for publishing peer-reviewed Lab Protocol articles, which describe protocols hosted on protocols.io. Read more information on sharing protocols at https://plos.org/protocols?utm_medium=editorial-email&utm_source=authorletters&utm_campaign=protocols. We look forward to receiving your revised manuscript. Kind regards, Emiliano Cè Academic Editor PLOS ONE Journal Requirements: When submitting your revision, we need you to address these additional requirements. 1.Please ensure that your manuscript meets PLOS ONE's style requirements, including those for file naming. The PLOS ONE style templates can be found at https://journals.plos.org/plosone/s/file?id=wjVg/PLOSOne_formatting_sample_main_body.pdf and https://journals.plos.org/plosone/s/file?id=ba62/PLOSOne_formatting_sample_title_authors_affiliations.pdf. 2. We note that you have stated that you will provide repository information for your data at acceptance. Should your manuscript be accepted for publication, we will hold it until you provide the relevant accession numbers or DOIs necessary to access your data. If you wish to make changes to your Data Availability statement, please describe these changes in your cover letter and we will update your Data Availability statement to reflect the information you provide. 3. Please review your reference list to ensure that it is complete and correct. If you have cited papers that have been retracted, please include the rationale for doing so in the manuscript text, or remove these references and replace them with relevant current references. Any changes to the reference list should be mentioned in the rebuttal letter that accompanies your revised manuscript. If you need to cite a retracted article, indicate the article’s retracted status in the References list and also include a citation and full reference for the retraction notice. [Note: HTML markup is below. Please do not edit.] Reviewers' comments: Reviewer's Responses to Questions Comments to the Author 1. Does the manuscript provide a valid rationale for the proposed study, with clearly identified and justified research questions? The research question outlined is expected to address a valid academic problem or topic and contribute to the base of knowledge in the field. Reviewer #1: Yes Reviewer #2: Yes ********** 2. Is the protocol technically sound and planned in a manner that will lead to a meaningful outcome and allow testing the stated hypotheses? The manuscript should describe the methods in sufficient detail to prevent undisclosed flexibility in the experimental procedure or analysis pipeline, including sufficient outcome-neutral conditions (e.g. necessary controls, absence of floor or ceiling effects) to test the proposed hypotheses and a statistical power analysis where applicable. As there may be aspects of the methodology and analysis which can only be refined once the work is undertaken, authors should outline potential assumptions and explicitly describe what aspects of the proposed analyses, if any, are exploratory. Reviewer #1: Yes Reviewer #2: Yes ********** 3. Is the methodology feasible and described in sufficient detail to allow the work to be replicable? Reviewer #1: Yes Reviewer #2: Yes ********** 4. Have the authors described where all data underlying the findings will be made available when the study is complete? The PLOS Data policy requires authors to make all data underlying the findings described in their manuscript fully available without restriction, with rare exception, at the time of publication. The data should be provided as part of the manuscript or its supporting information, or deposited to a public repository. For example, in addition to summary statistics, the data points behind means, medians and variance measures should be available. If there are restrictions on publicly sharing data—e.g. participant privacy or use of data from a third party—those must be specified. Reviewer #1: Yes Reviewer #2: Yes ********** 5. Is the manuscript presented in an intelligible fashion and written in standard English? PLOS ONE does not copyedit accepted manuscripts, so the language in submitted articles must be clear, correct, and unambiguous. Any typographical or grammatical errors should be corrected at revision, so please note any specific errors here. Reviewer #1: Yes Reviewer #2: Yes ********** 6. Review Comments to the Author Please use the space provided to explain your answers to the questions above and, if applicable, provide comments about issues authors must address before this protocol can be accepted for publication. You may also include additional comments for the author, including concerns about research or publication ethics. You may also provide optional suggestions and comments to authors that they might find helpful in planning their study. (Please upload your review as an attachment if it exceeds 20,000 characters) Reviewer #1: General comment Thank you for your thesis. Your research is very useful in establishing the reliability of TMG's methods. This study will be to investigate the within and between-day reliability of five different formulas to calculate Vc. The second aim will be to investigate the effect of different ISI during repeated stimulation on Vc, assessed by the example of M. biceps femoris and M. rectus femoris. However, there are some concerns that you should modify. Please refer following comments. Line 107 Please explain the reason of selection in muscle (RF and BF) for your study. Line 127 Please describe the location (setting) of your planned research. Line 134 The description of IPAC-SF should be combined with the inclusion criteria of line129. Line 141 When RF and BF are first mentioned, please use the formal names. Line 142 Why will you perform your study with ten stimuli? Please add the reason the number of the stimuli in method. Line 195 Please consider whether you will measure the thickness of the skin or subcutaneous tissue at the TMG measurement point. This may affect the measurement. Reviewer #2: General comments: This study protocol aims to investigate the reliability of Tensiomyography derived velocity calculations, the effect of inter-stimulus interval on velocity of contraction in the rectus femoris and biceps femoris. Overall, this study protocol is well written, with robust methodological considerations. This study protocol will benefit both practitioners and researchers to standardise which velocity of contraction equation, and inter-stimulus interval to use. This study could benefit from using normalised response speed (Vrn), which is a much more manageable and easier to interpret metric. Specific comments: Rewording a few sentences and phrases might make it easier for the flow of the manuscript. Introduction: Line 52 – electrochemical signal of the nervous system, and/or artificial electrical stimulation of the muscles (e.g., electrical stimulator). Line 58 – consider adding the following sentence instead “skeletal muscle stiffness, morphological, and structural changes” Line 71 – wouldn’t the line of slope be what time of contraction (Tc) measures? Please explain further. Line 73 – add “exists” after consensus Line 84 – perhaps providing the formulas of the other two methods of Vc calculation can be beneficial to the readers. Line 218 – some authors have used inter-electrode distances between 5-10 cm, could you explain why you chose 7cm in particular? What are its benefits over other inter-electrode distances? Methodology: Perhaps consider also adding normalised response speed (Vrn), as it provides a value that is much easier to interpret and manageable. Discussion: Line 319-320 – this line is a bit confusing, did you mean “an increase in Tc can be expected if Dm increases, even while Vc remains unchanged”? ********** 7. PLOS authors have the option to publish the peer review history of their article (what does this mean?). If published, this will include your full peer review and any attached files. If you choose “no”, your identity will remain anonymous but your review may still be made public. Do you want your identity to be public for this peer review? For information about this choice, including consent withdrawal, please see our Privacy Policy. Reviewer #1: No Reviewer #2: Yes: Angus Hunter [NOTE: If reviewer comments were submitted as an attachment file, they will be attached to this email and accessible via the submission site. Please log into your account, locate the manuscript record, and check for the action link "View Attachments". If this link does not appear, there are no attachment files.] While revising your submission, please upload your figure files to the Preflight Analysis and Conversion Engine (PACE) digital diagnostic tool, https://pacev2.apexcovantage.com/. PACE helps ensure that figures meet PLOS requirements. To use PACE, you must first register as a user. Registration is free. Then, login and navigate to the UPLOAD tab, where you will find detailed instructions on how to use the tool. If you encounter any issues or have any questions when using PACE, please email PLOS at figures@plos.org. Please note that Supporting Information files do not need this step. Submitted filename: review PONE-D-21-24120.docx Click here for additional data file. 5 Dec 2021 Reviewer#1: General comment Thank you for your thesis. Your research is very useful in establishing the reliability of TMG's methods. This study will be to investigate the within and between-day reliability of five different formulas to calculate Vc. The second aim will be to investigate the effect of different ISI during repeated stimulation on Vc, assessed by the example of M. biceps femoris and M. rectus femoris. However, there are some concerns that you should modify. Please refer following comments. Thank you for the positive and constructive feedback. We have added our responses below the respective comments and marked the corresponding changes in the text. Line 107 Please explain the reason of selection in muscle (RF and BF) for your study. We selected the RF and BF because they are the most frequently investigated muscles within studies reporting Vc. This information comes from the results of a scoping review which we plan to submit within the next few weeks. This reviews aim is to provide an overview of currently applied methodical concepts to determine Vc. The preregistration is openly available here: https://doi.org/10.17605/OSF.IO/ZKQMV We also added the following information in line 147: "The RF and BF were selected as they are the most frequently investigated muscles within studies reporting Vc." Line 127 Please describe the location (setting) of your planned research. The study will be conducted at the Institute for Applied Training Science in Leipzig, Germany. We also added the following information: Line 130: "This study will be conducted at the Institute for Applied Training Science." Line 141: "The study will be promoted via email distribution lists, flyers and word of mouth. Potential participants will be invited via informal invitation." Line 134 The description of IPAC-SF should be combined with the inclusion criteria of line129. Thank you for the advice. We moved the description of IPAC-SF up to line 133 so that it follows directly the inclusion criteria. Line 141 When RF and BF are first mentioned, please use the formal names. Thank you for pointing this out. However, RF and BF are first mentioned in the introduction section in line 82 where the corresponding abbreviations are also introduced. Line 142 Why will you perform your study with ten stimuli? Please add the reason the number of the stimuli in method. We added the following information in line 149: "The number of stimuli is consistent with a previous study which showed that Tc decreased significantly with ten stimuli [31], and which served as the reference for our sample size calculation." Line 195 Please consider whether you will measure the thickness of the skin or subcutaneous tissue at the TMG measurement point. This may affect the measurement. Thank you for this consideration. To our knowledge, there are conflicting findings on the influence of the skinfold thickness at the measurement point on TMG-parameters. In line with your suggestion, Calvo-Lobo et al. (10.1590/1806-9282.64.06.549) found a significant correlation between Dm and both the thickness of the skin and subcutaneous fat layer of the erector spinae muscle. In contrast, Diez-Vega et al. 2013 (10.1136/bjsports-2013-092558.61) found no significant correlation between Dm of the rectus femoris muscle and skinfold thickness. Similarly, de Paula Simola et al. 2015 (10.1519/JSC.0000000000000768) found no significant correlation between any of the TMG parameters of the rectus femoris muscle and the skinfold thickness at the measurement point. In view of these previous results, the influence of the skinfold thickness at the measuring point on the measurement results appears not yet clearly understood. However, we suggest that the skinfold thickness is not of crucial importance for determining the reproducibility of the different Vc formulas, as a change in skinfold thicknesses within the time period of this investigation is not to be expected. Reviewer #2: General comments: This study protocol aims to investigate the reliability of Tensiomyography derived velocity calculations, the effect of inter-stimulus interval on velocity of contraction in the rectus femoris and biceps femoris. Overall, this study protocol is well written, with robust methodological considerations. This study protocol will benefit both practitioners and researchers to standardise which velocity of contraction equation, and inter-stimulus interval to use. This study could benefit from using normalised response speed (Vrn), which is a much more manageable and easier to interpret metric. Specific comments: Rewording a few sentences and phrases might make it easier for the flow of the manuscript. Dear Prof. Hunter, thank you very much for your positive feedback and helpful comments on our manuscript. We have added our responses to your comments and marked the respective changes in the text. Introduction: Line 52 – electrochemical signal of the nervous system, and/or artificial electrical stimulation of the muscles (e.g., electrical stimulator). We added the following phrase in line 53: “… or artificial electrical stimulation of the muscle.” Line 58 – consider adding the following sentence instead “skeletal muscle stiffness, morphological, and structural changes” Thank you for the advice. We have adopted the suggested wording in line 59. Line 71 – wouldn’t the line of slope be what time of contraction (Tc) measures? Please explain further. Vc corresponds mathematically to the slope of the displacement-time curve within a defined time interval, calculated as the quotient of the respective displacement and the time needed to achieve it. Accordingly, Vc indicates the velocity or rate of muscle belly displacement in this respective time interval. On the other hand, Tc corresponds the time it takes for the muscle belly displacement to increase from 10% to 90% of Dm. Perhaps our expression in English is misleading at this point. To make our wording more precise, we added the word “time” in line 73. However, we would appreciate any suggestions if there is a more accurate expression of “the slope of the displacement-time curve”. Line 73 – add “exists” after consensus Thank you for pointing this out. We added the word in line 74. Line 84 – perhaps providing the formulas of the other two methods of Vc calculation can be beneficial to the readers. Thank you for the good advice, we added the formulas in line 86. Line 218 – some authors have used inter-electrode distances between 5-10 cm, could you explain why you chose 7cm in particular? What are its benefits over other inter-electrode distances? We decided for an IED of 7 cm based the results of Wilson et al 2018 (10.1371/journal.pone.0191965) and Wilson et al 2019 (10.1088/1361-6579/ab1cef). Both studies investigated the effect of changing the IED on contractile properties assessed via TMG. Wilson et al. 2018 investigated the RF muscle and found an increase in Dm when IED was increased from 5 cm to 7 cm, but no further increase when IED was increased to 9 cm or 11 cm. Wilson et al. 2019 investigated the BF muscle and found that Dm was higher with an IED of 7 cm compared to 6 cm, 5, cm or 4 cm. Wilson et al. 2019 also argued that if the IED is too large, the maximum stimulator output may be reached before the maximum Dm is obtained. This is in line with the findings of a study by Petrofsky et al. 2008 (10.1007/s00421-008-0700-3), who investigated the influence of the IED among other stimulation parameters on the distribution of the electrical current on the skin and the depth of its penetration into the muscle. Increasing the length of the IED from 10cm to 15cm or 20cm resulted in a more even, wider distribution of the current on the skin but a reduced penetration depth at the same time. The penetration depth of the current is an important factor, as the distribution of fiber types may differ at the muscle surface and deeper in the muscle tissue (Dahmane et al. 2005, 10.1016/j.jbiomech.2004.10.020). Consequently, an optimal IED would provide a wide distribution at the surface and at the same time an adequate penetration depth into the muscle, ensuring that as many motor units as possible are activated by the electric stimulus. Given the paucity of studies that have investigated the influence of the IED on TMG parameters, it can certainly be questioned whether an IED of 7 cm is optimal for TMG measurements of both BF and RF muscle. However, according to the current available evidence regarding IED configurations for these muscles, we believe that 7 cm is a reasonable choice. Methodology: Perhaps consider also adding normalised response speed (Vrn), as it provides a value that is much easier to interpret and manageable. Thank you for your suggestion. Do you mean the Vrn calculated by the formula first suggested by Valencic et al. 1997? If so, then this would correspond the fourth formula we mentioned in line 261: Vcnorm = 0.8*Dm / Tc*Dm = 0.8 / Tc. Discussion: Line 319-320 – this line is a bit confusing, did you mean “an increase in Tc can be expected if Dm increases, even while Vc remains unchanged”? Thank you for pointing this out. We want to express that both an increase in Dm while Tc remains unchanged and similarly a decrease in Tc while Dm remains unchanged will result in an increase in Vc. To hopefully make this point easier to understand, we changed this wording as follows (line 327): “An increase in Vc can be expected, if Dm increases while Tc remains unchanged as a higher displacement amplitude is achieved within the same time. Similarly, an increase in Vc can be also expected, if Tc shortens while Dm remains unchanged, as the same displacement amplitude is achieved within a shorter time.” Submitted filename: Response_to_Reviewers.docx Click here for additional data file. 17 Dec 2021 Reproducibility of knee extensor and flexor contraction velocity in healthy men and women assessed using tensiomyography: A study protocol PONE-D-21-24120R1 Dear Dr. Langen, We’re pleased to inform you that your manuscript has been judged scientifically suitable for publication and will be formally accepted for publication once it meets all outstanding technical requirements. Within one week, you’ll receive an e-mail detailing the required amendments. When these have been addressed, you’ll receive a formal acceptance letter and your manuscript will be scheduled for publication. An invoice for payment will follow shortly after the formal acceptance. To ensure an efficient process, please log into Editorial Manager at http://www.editorialmanager.com/pone/, click the 'Update My Information' link at the top of the page, and double check that your user information is up-to-date. If you have any billing related questions, please contact our Author Billing department directly at authorbilling@plos.org. If your institution or institutions have a press office, please notify them about your upcoming paper to help maximize its impact. If they’ll be preparing press materials, please inform our press team as soon as possible -- no later than 48 hours after receiving the formal acceptance. Your manuscript will remain under strict press embargo until 2 pm Eastern Time on the date of publication. For more information, please contact onepress@plos.org. Kind regards, Emiliano Cè Academic Editor PLOS ONE Additional Editor Comments (optional): Reviewers' comments: Reviewer's Responses to Questions Comments to the Author 1. Does the manuscript provide a valid rationale for the proposed study, with clearly identified and justified research questions? The research question outlined is expected to address a valid academic problem or topic and contribute to the base of knowledge in the field. Reviewer #1: Yes ********** 2. Is the protocol technically sound and planned in a manner that will lead to a meaningful outcome and allow testing the stated hypotheses? The manuscript should describe the methods in sufficient detail to prevent undisclosed flexibility in the experimental procedure or analysis pipeline, including sufficient outcome-neutral conditions (e.g. necessary controls, absence of floor or ceiling effects) to test the proposed hypotheses and a statistical power analysis where applicable. As there may be aspects of the methodology and analysis which can only be refined once the work is undertaken, authors should outline potential assumptions and explicitly describe what aspects of the proposed analyses, if any, are exploratory. Reviewer #1: Yes ********** 3. Is the methodology feasible and described in sufficient detail to allow the work to be replicable? Reviewer #1: Yes ********** 4. Have the authors described where all data underlying the findings will be made available when the study is complete? The PLOS Data policy requires authors to make all data underlying the findings described in their manuscript fully available without restriction, with rare exception, at the time of publication. The data should be provided as part of the manuscript or its supporting information, or deposited to a public repository. For example, in addition to summary statistics, the data points behind means, medians and variance measures should be available. If there are restrictions on publicly sharing data—e.g. participant privacy or use of data from a third party—those must be specified. Reviewer #1: Yes ********** 5. Is the manuscript presented in an intelligible fashion and written in standard English? PLOS ONE does not copyedit accepted manuscripts, so the language in submitted articles must be clear, correct, and unambiguous. Any typographical or grammatical errors should be corrected at revision, so please note any specific errors here. Reviewer #1: Yes ********** 6. Review Comments to the Author Please use the space provided to explain your answers to the questions above and, if applicable, provide comments about issues authors must address before this protocol can be accepted for publication. You may also include additional comments for the author, including concerns about research or publication ethics. You may also provide optional suggestions and comments to authors that they might find helpful in planning their study. (Please upload your review as an attachment if it exceeds 20,000 characters) Reviewer #1: Thanks for the correction. Your work will provide useful information for future readers of the TMG protocol. I look forward to your further research. ********** 7. PLOS authors have the option to publish the peer review history of their article (what does this mean?). If published, this will include your full peer review and any attached files. If you choose “no”, your identity will remain anonymous but your review may still be made public. Do you want your identity to be public for this peer review? For information about this choice, including consent withdrawal, please see our Privacy Policy. Reviewer #1: No 22 Dec 2021 PONE-D-21-24120R1 Reproducibility of knee extensor and flexor contraction velocity in healthy men and women assessed using tensiomyography: A study protocol Dear Dr. Langen: I'm pleased to inform you that your manuscript has been deemed suitable for publication in PLOS ONE. Congratulations! Your manuscript is now with our production department. If your institution or institutions have a press office, please let them know about your upcoming paper now to help maximize its impact. If they'll be preparing press materials, please inform our press team within the next 48 hours. Your manuscript will remain under strict press embargo until 2 pm Eastern Time on the date of publication. For more information please contact onepress@plos.org. If we can help with anything else, please email us at plosone@plos.org. Thank you for submitting your work to PLOS ONE and supporting open access. Kind regards, PLOS ONE Editorial Office Staff on behalf of Professor Emiliano Cè Academic Editor PLOS ONE
  50 in total

1.  The effect of recovery strategies on contractile properties using tensiomyography and perceived muscle soreness in professional soccer players.

Authors:  Ezequiel Rey; Carlos Lago-Peñas; Joaquín Lago-Ballesteros; Luis Casáis
Journal:  J Strength Cond Res       Date:  2012-11       Impact factor: 3.775

Review 2.  Progressive statistics for studies in sports medicine and exercise science.

Authors:  William G Hopkins; Stephen W Marshall; Alan M Batterham; Juri Hanin
Journal:  Med Sci Sports Exerc       Date:  2009-01       Impact factor: 5.411

3.  Assessment of neuromuscular function after different strength training protocols using tensiomyography.

Authors:  Rauno Á de Paula Simola; Nico Harms; Christian Raeder; Michael Kellmann; Tim Meyer; Mark Pfeiffer; Alexander Ferrauti
Journal:  J Strength Cond Res       Date:  2015-05       Impact factor: 3.775

4.  Assessment of Fatigue and Recovery in Male and Female Athletes After 6 Days of Intensified Strength Training.

Authors:  Christian Raeder; Thimo Wiewelhove; Rauno Álvaro De Paula Simola; Michael Kellmann; Tim Meyer; Mark Pfeiffer; Alexander Ferrauti
Journal:  J Strength Cond Res       Date:  2016-12       Impact factor: 3.775

5.  A Guideline of Selecting and Reporting Intraclass Correlation Coefficients for Reliability Research.

Authors:  Terry K Koo; Mae Y Li
Journal:  J Chiropr Med       Date:  2016-03-31

6.  Age-Related Slowing of Contractile Properties Differs Between Power, Endurance, and Nonathletes: A Tensiomyographic Assessment.

Authors:  Boštjan Šimunic; Rado Pišot; Jörn Rittweger; Hans Degens
Journal:  J Gerontol A Biol Sci Med Sci       Date:  2018-11-10       Impact factor: 6.053

7.  Whole muscle contractile parameters and thickness loss during 35-day bed rest.

Authors:  Rado Pisot; Marco V Narici; Bostjan Simunic; Maarten De Boer; Olivier Seynnes; Mihaela Jurdana; Gianni Biolo; Igor B Mekjavić
Journal:  Eur J Appl Physiol       Date:  2008-02-23       Impact factor: 3.078

8.  Tensiomyography Derived Parameters Reflect Skeletal Muscle Architectural Adaptations Following 6-Weeks of Lower Body Resistance Training.

Authors:  Matthew T Wilson; Andrew M F Ryan; Scott R Vallance; Alastair Dias-Dougan; James H Dugdale; Angus M Hunter; D Lee Hamilton; Lewis J Macgregor
Journal:  Front Physiol       Date:  2019-12-10       Impact factor: 4.566

9.  Markers for Routine Assessment of Fatigue and Recovery in Male and Female Team Sport Athletes during High-Intensity Interval Training.

Authors:  Thimo Wiewelhove; Christian Raeder; Tim Meyer; Michael Kellmann; Mark Pfeiffer; Alexander Ferrauti
Journal:  PLoS One       Date:  2015-10-07       Impact factor: 3.240

10.  Effectiveness of Two Cold Water Immersion Protocols on Neuromuscular Function Recovery: A Tensiomyography Study.

Authors:  Braulio Sánchez-Ureña; Daniel Rojas-Valverde; Randall Gutiérrez-Vargas
Journal:  Front Physiol       Date:  2018-06-26       Impact factor: 4.566

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.