Literature DB >> 34987785

Choices in hemodialysis therapies: variants, personalized therapy and application of evidence-based medicine.

Bernard Canaud1, Stefano Stuard2, Frank Laukhuf2, Grace Yan3, Maria Ines Gomez Canabal4, Paik Seong Lim5, Michael A Kraus6.   

Abstract

The extent of removal of the uremic toxins in hemodialysis (HD) therapies depends primarily on the dialysis membrane characteristics and the solute transport mechanisms involved. While designation of 'flux' of membranes as well toxicity of compounds that need to be targeted for removal remain unresolved issues, the relative role, efficiency and utilization of solute removal principles to optimize HD treatment are better delineated. Through the combination and intensity of diffusive and convective removal forces, levels of concentrations of a broad spectrum of uremic toxins can be lowered significantly and successfully. Extended clinical experience as well as data from several clinical trials attest to the benefits of convection-based HD treatment modalities. However, the mode of delivery of HD can further enhance the effectiveness of therapies. Other than treatment time, frequency and location that offer clinical benefits and increase patient well-being, treatment- and patient-specific criteria may be tailored for the therapy delivered: electrolytic composition, dialysate buffer and concentration and choice of anticoagulating agent are crucial for dialysis tolerance and efficacy. Evidence-based medicine (EBM) relies on three tenets, i.e. clinical expertise (i.e. doctor), patient-centered values (i.e. patient) and relevant scientific evidence (i.e. science), that have deviated from their initial aim and summarized to scientific evidence, leading to tyranny of randomized controlled trials. One must recognize that practice patterns as shown by Dialysis Outcomes and Practice Patterns Study and personalization of HD care are the main driving force for improving outcomes. Based on a combination of the three pillars of EBM, and particularly on bedside patient-clinician interaction, we summarize what we have learned over the last 6 decades in terms of best practices to improve outcomes in HD patients. Management of initiation of dialysis, vascular access, preservation of kidney function, selection of biocompatible dialysers and use of dialysis fluids of high microbiological purity to restrict inflammation are just some of the approaches where clinical experience is vital in the absence of definitive scientific evidence. Further, HD adequacy needs to be considered as a broad and multitarget approach covering not just the dose of dialysis provided, but meeting individual patient needs (e.g. fluid volume, acid-base, blood pressure, bone disease metabolism control) through regular assessment-and adjustment-of a series of indicators of treatment efficiency. Finally, in whichever way new technologies (i.e. artificial intelligence, connected health) are embraced in the future to improve the delivery of dialysis, the human dimension of the patient-doctor interaction is irreplaceable. Kidney medicine should remain 'an art' and will never be just 'a science'.
© The Author(s) 2021. Published by Oxford University Press on behalf of ERA.

Entities:  

Keywords:  dialysis modalities; evidence-based medicine; patient outcome; personalized medicine

Year:  2021        PMID: 34987785      PMCID: PMC8711767          DOI: 10.1093/ckj/sfab198

Source DB:  PubMed          Journal:  Clin Kidney J        ISSN: 2048-8505


  151 in total

1.  Home hemodialysis: a crazy idea in 1963: a memoir.

Authors:  Y Nosé
Journal:  ASAIO J       Date:  2000 Jan-Feb       Impact factor: 2.872

2.  Cardiopulmonary events during hemodialysis: effects of dialysis membranes and dialysate buffers.

Authors:  M A Munger; A Ateshkadi; A K Cheung; K K Flaharty; G J Stoddard; E H Marshall
Journal:  Am J Kidney Dis       Date:  2000-07       Impact factor: 8.860

3.  Section IV. Dialysis fluid purity.

Authors: 
Journal:  Nephrol Dial Transplant       Date:  2002       Impact factor: 5.992

4.  Residual Kidney Function Decline and Mortality in Incident Hemodialysis Patients.

Authors:  Yoshitsugu Obi; Connie M Rhee; Anna T Mathew; Gaurang Shah; Elani Streja; Steven M Brunelli; Csaba P Kovesdy; Rajnish Mehrotra; Kamyar Kalantar-Zadeh
Journal:  J Am Soc Nephrol       Date:  2016-05-11       Impact factor: 10.121

Review 5.  Blood pressure control in dialysis patients: importance of the lag phenomenon.

Authors:  B Charra; J Bergström; B H Scribner
Journal:  Am J Kidney Dis       Date:  1998-11       Impact factor: 8.860

6.  Hemodialysis-induced cardiac injury: determinants and associated outcomes.

Authors:  James O Burton; Helen J Jefferies; Nicholas M Selby; Christopher W McIntyre
Journal:  Clin J Am Soc Nephrol       Date:  2009-04-08       Impact factor: 8.237

7.  It is Time to Individualize the Dialysate Sodium Prescription.

Authors:  Carlo Basile; Carlo Lomonte
Journal:  Semin Dial       Date:  2015-08-31       Impact factor: 3.455

Review 8.  Dialysate Potassium, Dialysate Magnesium, and Hemodialysis Risk.

Authors:  Patrick H Pun; John P Middleton
Journal:  J Am Soc Nephrol       Date:  2017-10-09       Impact factor: 10.121

Review 9.  Transitional dialysis care units: A new approach to increase home dialysis modality uptake and patient outcomes.

Authors:  José A Morfín; Alex Yang; Elizabeth Wang; Brigitte Schiller
Journal:  Semin Dial       Date:  2017-10-05       Impact factor: 3.455

Review 10.  Nomenclature for renal replacement therapy in acute kidney injury: basic principles.

Authors:  Mauro Neri; Gianluca Villa; Francesco Garzotto; Sean Bagshaw; Rinaldo Bellomo; Jorge Cerda; Fiorenza Ferrari; Silvia Guggia; Michael Joannidis; John Kellum; Jeong Chul Kim; Ravindra L Mehta; Zaccaria Ricci; Alberto Trevisani; Silvio Marafon; William R Clark; Jean-Louis Vincent; Claudio Ronco
Journal:  Crit Care       Date:  2016-10-10       Impact factor: 9.097

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.