T. Sloane Guy, MD, MBA, and Jake L. Rosen, BAEndoaortic balloon occlusion (EABO) provides minimally invasive access to clamp the aorta during robotic mitral valve surgery.See Article page 84.The message displayed by Drs Bates and Chitwood offers comprehensive insight into the advantages of the transthoracic crossclamp, addressing concerns regarding safety and efficacy of the clamp in relation to endoaortic balloon occlusion (EABO). The transthoracic clamp modality mimics that of an open technique, allowing for antegrade placement of a cardioplegia catheter. Because of its reproducibility and similarity to standard techniques, the authors argue that within minimally invasive and robotic programs, the clamp makes for a less-steep learning curve and easier team adoption. However, the expanding scope of robotic mitral valve surgery indicates further discussion regarding even less-invasive alternatives, such as that enabled by EABO.EABO has been invaluable in our experience with robotic mitral valve surgery. Past studies have indicated noninferiority in outcomes of EABO to transthoracic crossclamping; Malvindi and colleagues revealed no statistically significant difference in postoperative complications, hospital length-of-stay, or in-hospital mortality. A large systematic review on the comparison of EABO to transthoracic clamping also supports the viability of EABO, with no significant difference in specific postoperative cardiovascular outcomes (ie, stroke and 30-day mortality).Furthermore, it is in our belief that the endoballoon provides distinct advantages relative to transthoracic crossclamping. First, contrary to the transthoracic clamp, the endoballoon applies a strictly transcatheter approach. Transthoracic clamping can lead to bleeding due to puncture of the aorta and has been shown to lead to more reoperations for bleeding relative to EABO. We are able to routinely place the cannulas, including the endoballoon, percutaneously without a cutdown. Whether needed or not, most surgeons currently perform generous thoracotomies to comfortably manage placement and removal of the antegrade cardioplegia catheter and also place the clamp when using a transthoracic clamp technique. Use of the EABO facilitates a completely endoscopic approach (visualization solely through an endoscope rather than direct visualization through incisions) to our robotic mitral valve surgeries. This method has been shown to be reproducible and effective in other high-volume centers as well. Conversely, transthoracic crossclamping has a risk of injury to the pulmonary artery or the left atrial appendage; aortic dissections are also potential complications. Superior vena cava obstruction can also complicate the operation, given its proximity to the clamp location; therefore, bicaval cannulation is mandatory with the transthoracic clamp technique. In the hands of a surgeon skilled in catheter-based techniques, these complications can be mitigated through the use of EABO. In addition, EABO is preferred in cases of a reoperation and where the aorta cannot be mobilized. Crossclamping is almost never a practical option in these reoperations because of adhesions at the ascending aorta; surgeons can use EABO in these cases.,, The other option in reoperations is fibrillatory arrest, but this approach has been associated with a greater stroke risk due to increased probability of air embolism as well as a decreased repair rate over replacement.Cases of proximal and distal balloon migration have been noted as concerns with EABO, potentially obstructing cardioplegia and the brachiocephalic or carotid arteries, respectively. While mobilization is a noted concern, this pitfall has been mitigated with proper use of newer-generation intra-aortic balloons (Edwards IntraClude) and intraoperative management of balloon deployment. Transesophageal echocardiography is needed with catheter insertion and during balloon inflation and deflation; elimination of slack in the catheter at the time of inflation virtually eliminates migration. Continual transesophageal echocardiography monitoring can be applied to minimize procedural risk of aortic dissection or mobilization of emboli, which may be the consequence of femoral cannulation rather than the balloon itself. Active surveillance of aortic root and bilateral upper-extremity artery pressures are employed to gain insight into balloon positioning and potential displacement.Advancements in minimally invasive cardiac surgery enable patients to have procedures done with rapid recovery and minimal invasion. EABO accomplishes this goal without sacrificing the safety and integrity of the mitral valve procedure itself. As current and future cardiac surgeons further adopt endovascular techniques, surgeons may feel more comfortable with the prospect of using EABO over transthoracic clamping. Catheter usage and wire skills are paramount to the success of safe endoballoon deployment. We believe that EABO is conducive to the mitral valve surgeon of the future.
Authors: James S Gammie; Yue Zhao; Eric D Peterson; Sean M O'Brien; J Scott Rankin; Bartley P Griffith Journal: Ann Thorac Surg Date: 2010-11 Impact factor: 4.330
Authors: James S Gammie; Joanna Chikwe; Vinay Badhwar; Dylan P Thibault; Sreekanth Vemulapalli; Vinod H Thourani; Marc Gillinov; David H Adams; J Scott Rankin; Mehrdad Ghoreishi; Alice Wang; Gorav Ailawadi; Jeffrey P Jacobs; Rakesh M Suri; Steven F Bolling; Nathaniel W Foster; Rachael W Quinn Journal: Ann Thorac Surg Date: 2018-07-19 Impact factor: 4.330
Authors: Gorav Ailawadi; Arvind K Agnihotri; John R Mehall; J Alan Wolfe; Brian W Hummel; Trevor M Fayers; R Saeid Farivar; Eugene A Grossi; T Sloane Guy; W Clark Hargrove; Junaid H Khan; Eric J Lehr; S Chris Malaisrie; Douglas A Murphy; Evelio Rodriguez; William H Ryan; Arash Salemi; Romualdo J Segurola; Richard J Shemin; J Michael Smith; Robert L Smith; Paul W Weldner; Scott M Goldman; Clifton T P Lewis; Glenn R Barnhart Journal: Innovations (Phila) Date: 2016 Jul-Aug