| Literature DB >> 34980393 |
Ting Li1, Ting Xiao1, Zhuoyun Zheng1, Yifan Li1, Songming Zhu1, Hosahalli S Ramaswamy2, Lihui Hu1, Yong Yu3.
Abstract
Self-cooling phase-transition units were built and tested to successfully carryout pressure shift freezing, high pressure thawing and subzero temperature microbial destruction kinetics. The design of these equipment has been progressively improved over the years as highlighted in this paper. Phase transition data on grape & apple juices, and sodium chloride (20%) & glucose solutions (20%) in Ice I were gathered and modeled using Simon-like and polynomial equations. Factors influencing the Ice I and water to Ice III phase transition position were evaluated, and found to be mainly affected by the solute in the aqueous solution. For pressure shifting freezing and pressure assisting freezing to Ice III, water and 20% sodium chloride solution were successfully employed and verified as cooling media for creating the temperature change pathway of potato and carrot. Using sodium chloride solution (20%) as the cooling medium, the phase transition pathway of apple juice and grape juice under high pressure for the phase transition of Ice I and metastable water to Ice III was established. This could be used in kinetic studies. The developed cooling unit concepts can use in any commercial high pressure equipment for subzero temperature treatment of foods without externally supplied cooling.Entities:
Keywords: Cooling system; High pressure freezing; Phase transition; Phase transition position
Mesh:
Substances:
Year: 2021 PMID: 34980393 DOI: 10.1016/j.foodres.2021.110857
Source DB: PubMed Journal: Food Res Int ISSN: 0963-9969 Impact factor: 6.475