Literature DB >> 34973551

An electrochemical PAH-modified aptasensor for the label-free and highly-sensitive detection of saxitoxin.

Beenish Noureen1, Najeeb Ullah2, Yulan Tian1, Liping Du3, Wei Chen1, Chunsheng Wu4, Ping Wang5.   

Abstract

Saxitoxin (STX), is one of the most dangerous and widespread paralytic shellfish toxins, causing a severe threat to the ecosystem and human health. So, it is important and highly essential to develop novel techniques for STX detection in a convenient, desirable, and low-cost manner. Herein, this study developed an electrolyte-insulator-semiconductor (EIS) sensor covered with a layer-by-layer prepared, positively-charged weak polyelectrolyte layer of poly (allylamine hydrochloride) (PAH) for the label-free detection of STX. The specific aptamer (Apt) sensitive to STX was electrostatically adsorbed onto the PAH layer. This leads to a preferentially flat orientation of the Apt within the Debye length, thus yielding a reduced charge-screening influence and a higher sensor signal. Each step of sensor surface modification, i.e. PAH adsorption, immobilization of Apt, and attachment of STX, was monitored by capacitance-voltage (C-V) and constant-capacitance (ConCap) measurements. Furthermore, atomic force microscopy (AFM) was employed to characterize the surface morphology and roughness of the PAH layer. Fluorescence microscopy was used to confirm the effective immobilization of Apt onto the PAH-modified EIS sensor. The results showed that the detection range of this aptasensor for STX detection was 0.5-100 nM and the detection limit was as low as 0.05 nM. Furthermore, this aptasensor showed good selectivity and 9 days' stability. The mussel tissue extraction test suggested that this aptasensor can be used to detect STX in real samples. This aptasensor provides a convenient approach for moderate, rapid, and label-free detection of marine biological toxins.
Copyright © 2021 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Aptamer; Biosensors; Electrolyte-insulator-semiconductor sensor; Marine toxin; Saxitoxin

Mesh:

Substances:

Year:  2021        PMID: 34973551     DOI: 10.1016/j.talanta.2021.123185

Source DB:  PubMed          Journal:  Talanta        ISSN: 0039-9140            Impact factor:   6.057


  1 in total

1.  Label-Free Detection of Saxitoxin with Field-Effect Device-Based Biosensor.

Authors:  Najeeb Ullah; Beenish Noureen; Yulan Tian; Liping Du; Wei Chen; Chunsheng Wu
Journal:  Nanomaterials (Basel)       Date:  2022-04-28       Impact factor: 5.719

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.