| Literature DB >> 34961904 |
Petter Frieberg1, Nicolas Aristokleous1,2, Pia Sjöberg3, Johannes Töger3, Petru Liuba4, Marcus Carlsson3,5.
Abstract
Computational fluid dynamics (CFD) modeling may aid in planning of invasive interventions in Fontan patients. Clinical application of current CFD techniques is however limited by complexity and long computation times. Therefore, we validated a "lean" CFD method to magnetic resonance imaging (MRI) and an "established" CFD method, ultimately aiming to reduce complexity to enable predictive CFD during ongoing interventions. Fifteen Fontan patients underwent MRI for CFD modeling. The differences between lean and established approach, in hepatic and total flow percentage to the left pulmonary artery (%LPA), power loss and relative wall shear stress area were 1.5 ± 4.0%, -0.17 ± 1.1%, -0.055 ± 0.092 mW and 1.1 ± 1.4%. Compared with MRI, the lean and established method showed a bias in %LPA of -1.9 ± 3.4% and -1.8 ± 3.1%. Computation time was for the lean and established approach 3.0 ± 2.0 min and 7.0 ± 3.4 h, respectively. We conclude that the proposed lean method provides fast and reliable results for future CFD support during interventions.Entities:
Keywords: Children; Congenital heart disease; Fontan circulation; Fontan procedure; Hemodynamics; Patient-specific CFD
Year: 2021 PMID: 34961904 DOI: 10.1007/s12265-021-10198-6
Source DB: PubMed Journal: J Cardiovasc Transl Res ISSN: 1937-5387 Impact factor: 4.132