| Literature DB >> 34961854 |
Shuk-Ching Wong1, Albert Ka-Wing Au2, Hong Chen2, Lithia Lai-Ha Yuen1, Xin Li3, David Christopher Lung4, Allen Wing-Ho Chu3, Jonathan Daniel Ip3, Wan-Mui Chan3, Hoi-Wah Tsoi3, Kelvin Kai-Wang To3, Kwok-Yung Yuen3, Vincent Chi-Chung Cheng1,5.
Abstract
Entities:
Year: 2021 PMID: 34961854 PMCID: PMC8696199 DOI: 10.1016/j.lanwpc.2021.100360
Source DB: PubMed Journal: Lancet Reg Health West Pac ISSN: 2666-6065
Figure 1Schematic representation of smoke test to demonstrate the potential mechanism of airborne transmission of Omicron (B.1.1.529), SARS-CoV-2 Variant of Concern between the rooms in a designated quarantine hotel for travelers.
Figure 1a: To demonstrate the direction of airflow between the guest room and corridor when the door is opened abruptly. The windows were closed in the corridor.
Figure 1b: To demonstrate the direction of airflow between the guest room and corridor when the door is opened, either slightly or widely. When the door was widely opened, we demonstrated inward airflow in the upper two-third of the room door and outward airflow near the floor level. When the door was slightly opened, we also showed slightly inward airflow near the floor. The windows were closed in the corridor.