Literature DB >> 3496058

St. Jude Medical prosthesis: valve-related deaths and complications.

K V Arom, D M Nicoloff, T E Kersten, W G Lindsay, W F Northrup.   

Abstract

Despite the hemodynamic improvement in cardiac valve prostheses, valve-related deaths and complications have remained a substantial source of morbidity and mortality. This follow-up study was carried out in April, 1986, in a group of 816 patients who received 876 St. Jude Medical prostheses between October, 1977, and October, 1984. One hundred fifty-five patients (37%) of the 422 having aortic valve replacement (AVR) and 88 (29%) of the 300 having mitral valve replacement (MVR) had concomitant coronary artery bypass grafting, and 94 patients (12%) had miscellaneous procedures performed in addition to valve replacement. Sixty-three patients died within the operative period, an operative mortality of 7.7%. Follow-up was complete for 98% of the patients; the mean follow-up was 42 months. At that time, 87 more patients had died, a late mortality of 11.9%. There were 13 valve-related deaths (4 in the AVR group, 7 in the MVR group, and 2 in the miscellaneous group); the causes of death were thromboembolism (7), anticoagulant-related hemorrhage (2), valve thrombosis (2), prosthetic valve endocarditis (1), and perivalvular leak (1). There were 37 thromboembolic episodes (1.78/100 patient-years) and 67 anticoagulant-related hemorrhages (3.22/100 patient-years), 46% of which necessitated transfusion. The incidence of valve thrombosis was 0.6% (4 patients). Perivalvular leak and prosthetic valve endocarditis occurred in 7 patients (1.0%) and 5 patients (0.7%), respectively. Reoperation was carried out in 6 patients (0.8%), but only for perivalvular leak. There were no deaths, no complications, and no clinical evidence of malfunction of the prosthetic valve.(ABSTRACT TRUNCATED AT 250 WORDS)

Entities:  

Mesh:

Year:  1987        PMID: 3496058     DOI: 10.1016/s0003-4975(10)60229-9

Source DB:  PubMed          Journal:  Ann Thorac Surg        ISSN: 0003-4975            Impact factor:   4.330


  2 in total

1.  Acute thrombotic occlusion of a prosthetic valve--treatment with tissue plasminogen activator.

Authors:  J C Roxburgh; P J Keeling; G E Venn
Journal:  J R Soc Med       Date:  1992-03       Impact factor: 5.344

2.  Mitral valve replacement with the SORIN valve. Long-term follow-up of 1,161 patients.

Authors:  A Pellegrini; T Colombo; E Quaini; C Russo; E Vitali; F Donatelli
Journal:  Tex Heart Inst J       Date:  1991
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.