Literature DB >> 3495435

Linear discriminant analysis of regional ejection fractions in the diagnosis of coronary artery disease.

K H Douglass, J M Links, D C Chen, D F Wong, H N Wagner.   

Abstract

We studied the application of linear discriminant analysis to the computer assisted interpretation of rest and exercise gated blood pool studies. Data were obtained in 45 patients in whom the presence or absence of coronary artery disease was determined by coronary angiography. Automated analysis of regional ejection fractions using a linear discriminant function (LDF) was compared to the fully automated calculation of global ejection fraction and to the subjective evaluation of wall motion. A LDF constructed from the data for the first 31 consecutive patients correctly classified 25/31 (81%). The change in global ejection fraction correctly classified 24/31 (77%) and wall motion analysis 25/31 (81%). In a distinct group of 14 patients the same LDF correctly classified 12/14 (86%), global ejection fraction 9/14 (64%) and wall motion analysis 10/14 (71%).

Entities:  

Mesh:

Year:  1987        PMID: 3495435     DOI: 10.1007/BF00284534

Source DB:  PubMed          Journal:  Eur J Nucl Med        ISSN: 0340-6997


  11 in total

1.  A simple kit for the preparation of 99mTc-labeled red blood cells.

Authors:  T D Smith; P Richards
Journal:  J Nucl Med       Date:  1976-02       Impact factor: 10.057

2.  A computerized breast thermographic interpreter.

Authors:  M Negin; M C Ziskin; C Piner; M S Lapayowker
Journal:  IEEE Trans Biomed Eng       Date:  1977-07       Impact factor: 4.538

3.  Computer diagnosis and discriminate analysis decision schemes.

Authors:  A W Templeton; K Bryan; R Waid; J Townes; M Huque; S J Dwyer
Journal:  Radiology       Date:  1970-04       Impact factor: 11.105

4.  Comparison of wall motion and regional ejection fraction at rest and during isometric exercise: concise communication.

Authors:  M M Bodenheimer; V S Banka; C M Fooshee; G A Hermánn; R H Helfant
Journal:  J Nucl Med       Date:  1979-07       Impact factor: 10.057

5.  The assessment of an edge detection algorithm in determining left ventricular ejection fraction using radio-nuclide multiple gated acquisition and contrast ventriculography.

Authors:  P C Jackson; R Allen-Narker; E R Davies; J R Rees; P Wilde; I Watt
Journal:  Eur J Nucl Med       Date:  1982

6.  Automatic analysis of left ventricular ejection fraction using stroke volume images.

Authors:  T R Nelson; J W Verba; V Bhargava; R Shabetai; R Slutsky
Journal:  Invest Radiol       Date:  1983 Mar-Apr       Impact factor: 6.016

7.  Fully automated data acquisition, processing, and display in equilibrium radioventriculography.

Authors:  M H Bourguignon; K H Douglass; J M Links; H N Wagner
Journal:  Eur J Nucl Med       Date:  1981

8.  A fully automated determination of the left ventricular region of interest in nuclear angiocardiography.

Authors:  M L Goris; J H McKillop; P A Briandet
Journal:  Cardiovasc Intervent Radiol       Date:  1981       Impact factor: 2.740

9.  Real-time radionuclide cineangiography in the noninvasive evaluation of global and regional left ventricular function at rest and during exercise in patients with coronary-artery disease.

Authors:  J S Borer; S L Bacharach; M V Green; K M Kent; S E Epstein; G S Johnston
Journal:  N Engl J Med       Date:  1977-04-14       Impact factor: 91.245

10.  Performance of a fully automated program for measurement of left ventricular ejection fraction.

Authors:  K H Douglass; P Tibbits; W Kasecamp; S T Han; D Koller; J M Links; H N Wagner
Journal:  Eur J Nucl Med       Date:  1982
View more
  1 in total

1.  Effect of pacing rate on regional left ventricular wall motion. Assessment by quantitative analysis of equilibrium radionuclide angiography.

Authors:  Z X He; J Darcourt; O Migneco; J P Camous; J Benoliel; F Bussière; M Baudouy; P Morand
Journal:  Int J Card Imaging       Date:  1995-09
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.