| Literature DB >> 34950257 |
Xia Tang1, Hong-Mei Jian1, Yi Guan2, Jie Miao3, Xin Liang1.
Abstract
INTRODUCTION: Preoperative computed tomography (CT)-guided localization is commonly employed to facilitate video-assisted thoracoscopic surgery (VATS)-guided diagnostic wedge resection of pulmonary nodules (PNs). AIM: The present meta-analysis was conducted with the goal of better evaluating the feasibility, safety, and clinical efficacy of preoperative CT-guided localization for multiple PNs (MPNs).Entities:
Keywords: computed tomography; localization; lung nodule; multiple
Year: 2021 PMID: 34950257 PMCID: PMC8669986 DOI: 10.5114/wiitm.2021.104199
Source DB: PubMed Journal: Wideochir Inne Tech Maloinwazyjne ISSN: 1895-4588 Impact factor: 1.195
Figure 1Flowchart of the meta-analysis
Characteristics of studies included in the meta-analysis
| Study | Year | Country | Number of patients | Number of nodules | Mean age [years] | Newcastle–Ottawa score |
|---|---|---|---|---|---|---|
| Iguchi [ | 2015 | Japan | 35 | 80 | 59.9 | 8 |
| Tseng [ | 2016 | Taiwan | 100 | 217 | 59.9 | 6 |
| Kadeer [ | 2018 | China | 76 | 194 | 55 | 8 |
| Li [ | 2018 | China | 51 | 126 | 58.9 | 8 |
| Fu [ | 2019 | China | 19 | 43 | 56.3 | 6 |
| Sun [ | 2019 | China | 16 | 34 | 47 | 6 |
| Teng [ | 2020 | China | 31 | 68 | 55 | 8 |
| Yang [ | 2020 | China | 17 | 37 | Not given | 6 |
Characteristics of procedures
| Study | Mean lesion size | Localized materials | TS of localization (per nodule) | TS of localization (per patient) | TS of wedge resection (per nodule) | TS of wedge resection (per patient) | Complication rate |
|---|---|---|---|---|---|---|---|
| Iguchi [ | 0.8 cm | Hook-wire | 96% | 91% | Not given | Not given | 90% |
| Tseng [ | 0.8 cm | Methylene blue | 99% | 98% | 100% | 100% | 55% |
| Kadeer [ | 0.7 cm | Hook-wire | 88% | 72% | 96% | 85% | 64% |
| Li [ | 0.8 cm | Coil | 96% | 90% | Not given | Not given | 24% |
| Fu [ | 0.7 cm | Coil | 98% | 95% | 100% | 100% | 16% |
| Sun [ | 0.7 cm | Hook-wire | 100% | 100% | 100% | 100% | 13% |
| Teng [ | 0.7 cm | Coil | 99% | 97% | 100% | 100% | 13% |
| Yang [ | 0.9 cm | Coil | 97% | 94% | 100% | 100% | Not given |
TS – technical success.
Figure 2Forest plots of the technical success rate of localization (based on PNs) (A) Technical success rate of localization (based on patients) (B) and complication rate (C)
Subgroup analyses
| Variable | TS of localization (per nodule) | TS of localization (per patient) | Complication rate |
|---|---|---|---|
| Total | 97% | 92% | 40% |
| Localized materials: | |||
| Coil | 98% | 95% | 18% |
| Hook-wire | 92% | 82% | 56% |
| 0.104 | 0.117 | 0.163 | |
TS – technical success.