| Literature DB >> 34947286 |
Zhilu Jiang1,2, Siyao Li1,2, Chuanqing Fu1,2, Zheng Dong1,2, Xuefeng Zhang3, Nanguo Jin4, Tian Xia4.
Abstract
Steel corrosion has become the main reason for the deterioration of reinforced concrete structures. Due to the heterogeneity of concrete and the spatial variation of environmental conditions, macrocell corrosion is often formed by localized corrosion, which is more detrimental if the anode is supported by large numbers of cathodes. The macrocell corrosion caused by concrete carbonation has been seldom studied. Furthermore, the influence of geometrical conditions on cathode-controlled corrosion in the chloride environment needs to be further clarified. In this work, the macrocell corrosion of steel embedded in concrete specimens exposed to accelerated carbonation, chloride contamination, and chloride penetration is studied using a modified ASTM G109 method. Concrete specimens with various binder types, geometrical parameters (i.e., concrete cover thickness and the diameter of embedded steel), and boundary conditions were tested. A simplified mathematical model for the prediction of the steel corrosion rate was developed considering two-dimensional oxygen diffusion. The results showed that, at the same level of anodic potential drops, the corrosion current rate in chloride-induced corrosion is higher than that of carbonation-induced corrosion. Chloride contamination is less detrimental to concrete incorporated with slag and pulverized fly ash than it is to pure ordinary Portland cement (OPC), likely due to enhanced chloride binding capacity. The results also indicated that the model considering two-dimensional diffusion can accurately predict the cathodic reaction process on corroded steel bars, which provides a theoretical basis for considering the correction coefficient of steel bar position in the establishment of a steel bar corrosion rate model.Entities:
Keywords: carbonation; chloride penetration; concrete; corrosion of steel; macrocell corrosion
Year: 2021 PMID: 34947286 PMCID: PMC8704281 DOI: 10.3390/ma14247691
Source DB: PubMed Journal: Materials (Basel) ISSN: 1996-1944 Impact factor: 3.623
Mix proportion of concrete.
| Parameters | Concrete Group | ||
|---|---|---|---|
| OPC | GGBS | FA | |
| Water-to-binder ratio | 0.53 | 0.53 | 0.53 |
| Cement (kg/m3) | 370 | 185 | 258 |
| Slag (kg/m3) | 0 | 185 | 0 |
| Fly ash (kg/m3) | 0 | 0 | 110 |
| Water (kg/m3) | 187 | 187 | 186 |
| Sand (kg/m3) | 749 | 750 | 747 |
| Coarse aggregate (kg/m3) | 1110 | 1112 | 1107 |
Figure 1Configuration of modified ASTM G109 specimens to simulate the macrocell corrosion in concrete structure exposed to (a) accelerated carbonation; (b) internally admixed chloride; (c) cyclic drying–wetting chloride penetration. (a = 150 mm, b = 10 mm, c = 15 mm, L = 250 mm, d = 25 mm, and e = 30 mm).
Figure 2Strength and porosity in concrete: (a) time-dependent evolution of compressive strength; (b) time-dependent evolution of porosity (the initial porosity, i.e., the porosity at 0 day was calculated based on the mix proportion); (c) correlation between compressive strength and porosity.
Figure 3Carbonation and chloride resistance of concrete: (a) time-dependent evolution of carbonation depth; (b) depth-dependent profiles of the free chloride concentration.
pH value of concrete before and after carbonation.
| Condition | Concrete Group | ||
|---|---|---|---|
| OPC | GGBS | FA | |
| 28-day moist curing | 13.34 | 12.75 | 12.59 |
| 112-day carbonation | 9.15 | 9.07 | 9.14 |
Figure 4Time-dependent evolution of corrosion potential in the top steel (anode) embedded in concrete exposed to (a) accelerated carbonation; (b) chloride contamination; (c) chloride penetration; (d) the correlation between admixed chloride content and the corrosion potentials.
Figure 5Time-dependent evolution of corrosion current density in concrete exposed to (a) accelerated carbonation; (b) chloride contamination; (c) chloride penetration.
Figure 6Time-dependent evolution of corrosion current density in concrete specimens with various geometrical parameters and boundary conditions: (a) effect of cover thickness; (b) effect of steel diameter; (c) effect of sealed condition.
Comparison between measured and modeled corrosion current density (×10−7 A/cm2) for different environmental conditions.
| Conditions | OPC | GGBS | FA | |||
|---|---|---|---|---|---|---|
| Measured | Modeled | Measured | Modeled | Measured | Modeled | |
| Carbonated | - | - | 2.05 | 2.16 | 1.40 | 1.46 |
| Internally admixed with 1.5% NaCl | 0.78 | 1.44 | 0.52 | 1.20 | 0.66 | 1.02 |
| Internally admixed with 3% NaCl | 2.62 | 2.31 | 0.68 | 1.62 | 1.03 | 1.45 |
| Internally admixed with 4.5% NaCl | 4.46 | 3.71 | 0.71 | 2.61 | 2.60 | 3.09 |
| Chloride penetration | 11.72 | 2.22 | - | - | - | - |
Comparison between measured and modeled corrosion current density (×10−7 A/cm2) for different geometrical parameters and boundary conditions.
| Conditions | Measured | Modeled |
|---|---|---|
| Cover thickness | ||
| 10 mm | 5.21 | 4.67 |
| 15 mm | 3.16 | 3.03 |
| 20 mm | 3.00 | 2.17 |
| Steel bar diameter | ||
| 10 mm | 1.48 | 3.14 |
| 16 mm | 3.16 | 3.03 |
| 22 mm | 2.69 | 2.92 |
| Sealing of lateral surfaces | ||
| Fully sealed | 3.16 | 3.03 |
| Upper half sealed | 5.53 | 6.05 |