| Literature DB >> 34945470 |
Zina T Alkanan1, Ammar B Altemimi1, Asaad R S Al-Hilphy1, Francesco Cacciola2, Salam A Ibrahim3.
Abstract
Ohmic-vacuum combination heating is a common method used in the food industry as a concentration process. In the present study, an OH-VC combination heating system was developed for producing tomato paste at temperatures of 70, 80, and 90 °C and pressure of 0.3, 0.5, and 0.7 bar and electric field of 1.82, 2.73, and 3.64 V/cm using a central composite design. The effects of heating conditions on the quality and sensory evaluation of tomato paste were also evaluated. Each combination of temperature, pressure, and the electric field was quantified for specific energy consumption, energy efficiency, and productivity. A decrease of 35.08% in the amount of acid ascorbic and lycopene content 19.01%, using conventional heating compared to ohmic-vacuum heating under optimized conditions, was attained. The results also highlighted an increase in the amount of HMF (69.79%) and PME (24.33%) using conventional heating compared to ohmic-vacuum heating under optimized conditions. Ascorbic acid, lycopene, titratable acidity, productivity, energy efficiency was higher than conventional heating; on the other hand, HMF, PME, pH, SEC were lower than conventional heating at the applied OH-VC process. No significant effects between OH-VC and conventional heating on the TSS were observed. In addition, OH-VC heating was highly efficient in the inhibition of bacterial growth. Further, a minor effect on the sensory properties of tomato paste with OH-VC heating compared to the conventional treatment. The obtained results indicate a strong potential for an OH-VC combination heating system as a rapid-heating, high-efficiency alternative for saving electrical energy consumption and preserving nutritional value.Entities:
Keywords: microbiological stability; ohmic-vacuum combination; phytochemicals; tomato
Year: 2021 PMID: 34945470 PMCID: PMC8700374 DOI: 10.3390/foods10122920
Source DB: PubMed Journal: Foods ISSN: 2304-8158
Figure 1(A): Laboratory-made mechanical piston, (B): Engineering drawing of a mechanical piston, 1. Framework; 2. Lever; 3. Mechanical press; 4. Steel shaft; 5. Pressure disc; 6. Perforated cylinder; 7. Juice collecting tank.
Figure 2(A). Photograph of the actual ohmic-vacuum (OH-VC) combination heating device. (B). Schematic diagram of (OH-VC) consisting of 1. Pressure vacuum gauge; 2. Pressure vacuum calibration valve; 3. Heating cylinder; 4. Electricity source; 5. Variac; 6. Stainless steel electrodes; 7. Thermocouple; 8. Temperature controller; 9. Coldwater circulation unit; 10. Pipes; 11. Glass heat Exchanger; 12. Moisture trap; 13. Piping; 14. Moisture trap; 15. Vacuum pump; 16. Valve.
Settings of variables for the experiment design.
| Symbols | Independent Variables | −1 | 0 | 1 |
|---|---|---|---|---|
|
| Temperature (°C) | 70 | 80 | 90 |
|
| Pressure (bar) | 0.3 | 0.5 | 0.7 |
|
| Electrical field (V/cm) | 1.82 | 2.73 | 3.64 |
Independent variables of the study.
| Run | Temperature (°C) | Pressure (Bar) | Electrical Conductivity (V/cm) |
|---|---|---|---|
| 1 | 80 | 0.50 | 1.82 |
| 2 | 70 | 0.30 | 3.64 |
| 3 | 70 | 0.50 | 3.64 |
| 4 | 70 | 0.70 | 3.64 |
| 5 | 80 | 0.50 | 2.73 |
| 6 | 80 | 0.50 | 2.73 |
| 7 | 80 | 0.50 | 2.73 |
| 8 | 70 | 0.50 | 3.64 |
| 9 | 80 | 0.70 | 2.73 |
| 10 | 90 | 0.50 | 2.73 |
| 11 | 90 | 0.70 | 1.82 |
| 12 | 80 | 0.30 | 3.64 |
| 13 | 80 | 0.50 | 1.82 |
| 14 | 80 | 0.30 | 2.73 |
| 15 | 80 | 0.50 | 2.73 |
| 16 | 90 | 0.70 | 1.82 |
| 17 | 90 | 0.30 | 2.73 |
| 18 | 70 | 0.30 | 2.73 |
| 19 | 90 | 0.50 | 2.73 |
| 20 | 80 | 0.70 | 1.82 |
Experiment design and responses of pH, titratable acidity %, TSS brix, density kg/m3, ascorbic acid AA mg/100 g, lycopene mg/kg, HMF ppm, and PME unit/mL.
| Independent Variables | pH | Titratable Acidity | TSS | Density | AA | Lycopene | HMF | PME | |||
|---|---|---|---|---|---|---|---|---|---|---|---|
| RUN | Electric Field (V/cm) | Temperature | Pressure (Bar) | ||||||||
| (°C) | |||||||||||
| 1 | 1.82 | 70 | 0.7 | 4.2 | 0.33 | 26 | 1074.07 | 61.6 | 27.53 | 5.854 | 0.0000541 |
| 2 | 3.64 | 90 | 0.3 | 4.4 | 0.34 | 29 | 1075.26 | 48.42 | 27.53 | 1.561 | 0.0000581 |
| 3 | 3.64 | 90 | 0.7 | 4.2 | 0.39 | 29 | 1075.26 | 22 | 24.79 | 4.972 | 0.0000.225 |
| 4 | 3.64 | 70 | 0.3 | 4.1 | 0.34 | 28 | 1079.79 | 44 | 26.26 | 4.195 | 0.0000751 |
| 5 | 2.73 | 70 | 0.5 | 4.1 | 0.38 | 27 | 1074.07 | 66.35 | 24.78 | 5.718 | 0.0000344 |
| 6 | 2.73 | 80 | 0.5 | 4.2 | 0.33 | 27 | 1068.93 | 44.2 | 26.12 | 1.886 | 0.0000585 |
| 7 | 2.73 | 80 | 0.5 | 4.2 | 0.32 | 27 | 1068.93 | 43.98 | 26.25 | 1.861 | 0.0000571 |
| 8 | 3.64 | 70 | 0.7 | 4.3 | 0.39 | 28 | 1079.79 | 27.84 | 25.74 | 3.851 | 0.0000545 |
| 9 | 2.73 | 80 | 0.5 | 4.2 | 0.36 | 27 | 1068.93 | 44.34 | 26.91 | 1.561 | 0.0000408 |
| 10 | 2.73 | 90 | 0.3 | 4.2 | 0.37 | 29 | 1075.26 | 57.61 | 27.97 | 1.587 | 0.0000118 |
| 11 | 1.82 | 80 | 0.5 | 4.2 | 0.35 | 27 | 1068.93 | 26.66 | 25.89 | 3.48 | 0.0000456 |
| 12 | 3.64 | 80 | 0.5 | 4.3 | 0.36 | 28 | 1074.66 | 52.31 | 27.33 | 4.371 | 0.0000445 |
| 13 | 1.82 | 90 | 0.7 | 4.1 | 0.46 | 26 | 1058.08 | 22.03 | 24.21 | 3.731 | 0.000636 |
| 15 | 2.73 | 80 | 0.7 | 4.2 | 0.41 | 26 | 1058.08 | 40.51 | 25.67 | 1.783 | 0.0000362 |
| 16 | 2.73 | 80 | 0.3 | 4.1 | 0.36 | 27 | 1068.93 | 66.17 | 26.15 | 1.82 | 0.0000511 |
| 17 | 1.82 | 70 | 0.3 | 4.2 | 0.33 | 28 | 1074.66 | 67.6 | 26.77 | 1.725 | 0.0000582 |
| 18 | 2.73 | 80 | 0.5 | 4.2 | 0.33 | 26 | 1068.34 | 43.88 | 28.18 | 3.48 | 0.000591 |
| 19 | 2.73 | 80 | 0.5 | 4.2 | 0.39 | 28 | 1074.66 | 44.51 | 26.85 | 1.587 | 0.0000525 |
| 20 | 2.73 | 80 | 0.5 | 4.2 | 0.38 | 27 | 1068.93 | 43.95 | 26.23 | 1.908 | 0.0000543 |
Regression coefficients, R2, and p values of the model for eight dependent variables for OH-VC combination heating samples.
| Regression Coefficient | pH | T.A | Density | A.A | Lycopene | HMF | PME |
|---|---|---|---|---|---|---|---|
| b0 | 4.19106 | 0.978 | 658.3262 | 201.0785 | 269.6063 | 94.7595 | 0.017990129 |
| b1 | 0.050487 | 0.1848 | 46.91637 | −57.1125 | −142.694 | −10.2135 | −0.004534519 |
| b2 | 0.050112 | −0.02523 | 5.641375 | −1.46955 | −4.91786 | −1.96993 | −0.000283933 |
| b1b2 | −0.04996 | 0.11 | 1510.327 | 146.165 | −3.59318 | 12.27199 | −0.018056761 |
| b12 | 0.037312 | −0.00234 | −0.78719 | 0.661925 | 2.633469 | 0.034416 | 5.23476 × 10−5 |
| b22 | 0.012738 | 0.00021 | −118.078 | −0.6875 | 17.30437 | −0.99756 | 0.005480062 |
| b1b22 | −0.06261 | --- | −20.0375 | −2.49 | −0.5 | 0.220313 | 0.0002211 |
| b12 b2 | 0.072873 | - | 3.030672 | 10.85322 | 1.47565 | 0.000114884 | |
| R2 | 0.982955 | 0.666402 | 0.873249 | 0.676866 | 0.945965 | 0.697817 | 0.927586 |
| 0.0003 | 0.0049 | 0.0056 | 0.0107 | 0.0087 | 0.0792 | 0.0006 | |
| 0.8048 | 0.7833 | 0.0001 | 0.0992 | 0.4158 | 0.0001 |
Mean of dependent variables OH-VC combination heating under optimized conditions of 3.64 V/cm, 87.30 °C, and 0.3 bars compared with conventional heating.
| Dependent Variable | OH-VC | Conventional Heating |
|---|---|---|
| AA (mg/100 g) | 67.76 ± 1.244 a | 50.16 ± 1.244 b |
| Lycopene (mg/kg) | 33.93 ± 1.435 a | 28.51 ± 1.173 |
| HMF (ppm) | 1.055 a ± 0.052 | 3.493 ± 0.77 b |
| PME (unit/mL) | 0.1135 × 10−3 ± 0.2121 × 106 | 0.15 ×10−3± 0.848528 × 10−6 b |
| pH | 4.2 a | 4.3 a |
| Titratable acidity (%) | 0.42 ± 0.42 a | 0.35 ± 0.0141 b |
| TSS (brix) | 27.5 ± 0.707 a | 28 ± 1.414 a |
| Total plate count | 0 | 0 |
|
| 0 | 0 |
| Yeast and mold | 0 | 0 |
a–b Means with same superscripts across a row are not significantly different.
Figure 3Response surface model plot showing the effects of independent variables on titratable acidity (%).
Figure 4Response surface model plot showing the effects of independent variables on TSS (brix): panel (A), temperature and electric field; panel (B), pressure and electric field; and panel (C) temperature and pressure.
Figure 5Response surface model plot showing the effects of independent variables on the density (kg/m3): panel (A), temperature and electric field; panel (B), pressure and electric field; and panel, temperature and pressure (C).
Mean of dependent variables for ohmic-vacuum (OH-VC) combination heating under optimized conditions of 3.64 V/cm, 87.30 °,C and 0.3 bar compared with conventional heating.
| Dependent Variable | OH-VC | Conventional Heating |
|---|---|---|
| Electrical Conductivity (V/cm) | 13.08 ± 2.01 a | _ |
| Efficiency (%) | 36.87 ± 2.985 a | 1.3207 ± 0.12 b |
| SEC (kJ/kg) | 6701.750 ± 908.5 a | 31,233.33 ± 805.65 b |
| Productivity kg/h | 0.2763 ± 0.098 a | 0.089647 ± 0.01 b |
a–b Means with same superscripts across a row are not significantly different.
Sensory evaluation scores of the ohmic heating treated samples under optimum conditions at an electric field strength of 3.64 V/cm, a temperature of 87.30 °C, and a pressure of 0.3 bar, and the conventional heating.
| Sample | Color | Texture | Taste | Appearance | Overall Acceptability |
|---|---|---|---|---|---|
| OH-VC | 8.6 ± 0.632 a | 8.33 ± 0.723 a | 8.13 ± 0.743 a | 8.13 ± 0.990 a | 8.13 ± 0.854 a |
| Conventional heating | 6.63 ± 0.972 b | 7.3 ± 1.130 b | 8.03 ± 0.718 a | 7.8 ± 0.797 a | 7.36 ± 0.854 b |
a–b Means with same superscripts across a row are not significantly different.