Literature DB >> 34930042

A Comparison of the Two-Minute Walk Test (2MWT) and Comprehensive High-level Activity Mobility Predictor (CHAMP) in People with a Leg Prosthesis.

Robert S Gailey1, Ignacio Gaunaurd1, Sara J Morgan2,3, Anat Kristal1, Geoffrey S Balkman2, Eavey M Newton1, Jose J Palomo1, Kevin M Shay1, Rana Salem2, Brian J Hafner2.   

Abstract

OBJECTIVE: To determine if the two-minute walk test (2MWT) could serve as an alternative measure of high-level mobility in lower limb prosthesis users when circumstances preclude administration of the Comprehensive High-level Activity Mobility Predictor (CHAMP).
DESIGN: Cross-sectional study.
SETTING: Indoor recreational athletic field and gymnasium.
SUBJECTS: Fifty-eight adult lower limb prosthesis users with unilateral or bilateral lower limb amputation who participate in recreational athletic activities. INTERVENTION: N/A. MAIN MEASURES: The 2MWT and CHAMP while using their preferred prosthesis(es) on an indoor artificial athletic field or hardwood gymnasium floor.
RESULTS: Thirty-nine men and nineteen women with a median age of 38.3 years participated in the study. Most participants experienced amputation(s) due to trauma (62%) or tumor (10%) and were generally higher functioning (K4 (91.4%) and K3 (8.6%)). The median (range) score for the CHAMP was 23.0 points (1.5-33.5) and the mean ± standard deviation (range) 2MWT distance walked was 188.6 ± 33.9 m (100.2-254.3 m). The CHAMP demonstrated a strong positive relationship with 2MWT (r = 0.83, p < 0.001). The 2MWT distance predicted 70% of the variance in CHAMP score.
CONCLUSIONS: Although the 2MWT does not test multi-directional agility like the CHAMP, they were found to be highly correlated. If space is limited, the two-minute walk test can serve as an alternative measure for assessing high-level mobility capabilities in lower limb prosthesis users.

Entities:  

Mesh:

Year:  2021        PMID: 34930042     DOI: 10.1177/02692155211069323

Source DB:  PubMed          Journal:  Clin Rehabil        ISSN: 0269-2155            Impact factor:   3.477


  1 in total

1.  High-Level Mobility of Trans-Tibial Prosthesis Users Wearing Commercial and sPace Energy-Storing Prosthetic Feet.

Authors:  Thanyaporn Rakbangboon; Gary Guerra; Saloottra Kla-Arsa; Uthumporn Padungjaroen; Pairat Tangpornprasert; Chanyaphan Virulsri; Kazuhiko Sasaki
Journal:  Int J Environ Res Public Health       Date:  2022-10-02       Impact factor: 4.614

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.