Literature DB >> 34922259

The effects of SARS-CoV-2 on hearing thresholds in COVID-19 patients with non-hospitalized mild disease.

Osman Durgut1, Mesut Karataş2, Çağlar Çelik2, Oğuzhan Dikici2, Fevzi Solmaz2, Sündüz Gencay2.   

Abstract

INTRODUCTION: COVID-19 may have many nonspecific symptoms, such as hearing loss, tinnitus and dizziness. This study aims to investigate the effects of SARS-CoV-2 on the hearing thresholds of patients with COVID-19.
METHODS: A total of 20 patients aged 20-55 years who were diagnosed with COVID-19 were included in this study. The relationship between the pure-tone thresholds of patients before and after COVID-19 was evaluated.
RESULTS: There was no statistically significant difference between bone conduction pure-tone thresholds in all frequencies before and after COVID-19.
CONCLUSION: SARS-CoV-2 has no effects on the hearing thresholds in patients with non-hospitalized mild COVID-19 disease. Further studies are needed to investigate the possible effects of SARS-CoV-2 on the auditory system.
Copyright © 2021 Elsevier Inc. All rights reserved.

Entities:  

Keywords:  COVID-19; Hearing loss; Pandemic; SARS-CoV-2

Mesh:

Year:  2021        PMID: 34922259      PMCID: PMC8669941          DOI: 10.1016/j.amjoto.2021.103320

Source DB:  PubMed          Journal:  Am J Otolaryngol        ISSN: 0196-0709            Impact factor:   1.808


Introduction

In late December 2019, a group of pneumonia cases of unknown etiology was reported in Wuhan, China [1]. This life-threatening disease, called COVID -19, was caused by severe acute respiratory syndrome coronavirus-2 (SARS-CoV-2) and spread worldwide [2]. World Health Organization declared the pandemic on 11 March 2020 due to alarming spread [3]. Since then, COVID-19 has threatened people's lives. Patients with COVID-19 have nonspecific complaints of other respiratory infections. Fever, cough, fatigue and shortness of breath sore are the main symptoms [4], [5]. Other symptoms include muscle ache, headache, confusion and sore throat [4], [5]. There are publications reporting that half of the patients have a loss of smell and taste [6]. Nasal congestion and rhinorrhea are very rare, unlike other upper respiratory infections [4]. However, some patients with COVID-19 present with other nonspecific symptoms as hearing loss [7], tinnitus [7], dizziness [7], keratoconjunctivitis [8], cutaneous [9] and gastrointestinal findings [5]. Our knowledge of this disease is limited and we can face many clinical manifestations. As studies on the disease increase, previously unknown effects of the disease are understood day by day. Viral infections are known to affect the audiovestibular system [10]. Although the effects of SARS-CoV-2 on the audiovestibular system are not known exactly, coronaviruses have been reported to be neuro-tropic and neuro-invasive [11], [12]. Therefore, it may have effects on the auditory system. This study aims to investigate the effects of SARS-CoV-2 on the hearing thresholds of patients with COVID-19. To our knowledge, this is the first study on this topic in the literature.

Methods

The present study was conducted in the ENT clinic of the tertiary education and research hospital. A total of 20 patients aged 20–55 years who were diagnosed with COVID-19 were included in this study. Patients who had a pure-tone audiometry test in our clinic in the last 12 months and subsequently had COVID-19 disease were included. Patients with a history of hearing loss, chronic ear disease and ear surgery were excluded from this study. All patients underwent otoscopic examination, pure-tone audiometry and tympanograms. SARS-CoV-2 diagnostic confirmation of all patients was performed by real-time reverse transcriptase-polymerase chain reaction (RT-PCR) technique on nasopharyngeal swab sample. All of the participants were outpatients with mild COVID-19 disease. Pre-COVID-19 pure-tone thresholds values were used as control. Pure-tone audiometry was performed with the GSI AudioStar Pro device. Air conduction pure-tone thresholds were tested at 250 Hz, 500 Hz, 1000 Hz, 2000 Hz, 4000 Hz and 8000 Hz. Bone conduction pure-tone thresholds were tested at 500 Hz, 1000 Hz, 2000 Hz and 4000 Hz. The average pure-tone thresholds at 500 Hz, 1000 Hz and 2000 Hz were used to estimate the level of hearing impairment. Tympanometry was performed in a quiet room using the Maico MI34 device. All post-COVID-19 audiometric investigations were performed by the same audiologist. This study was performed in accordance with the requirements of the declaration of Helsinki after obtaining approval by the Ethics Committee of the tertiary research hospital (decision number 2011-KAEK-25 2021/03-07). Informed consent was obtained from all patients. Data analysis was performed using the SPSS software, version 23.0 (Statistical Package for the Social Sciences, Chicago, IL, USA). Paired t-test was used to evaluate the relationship between pure-tone thresholds before and after COVID-19. p-Value <0.05 was considered statistically significant.

Results

A total of 20 patients, seven male and 13 female, diagnosed with COVID-19 were included in this study. Hearing thresholds of 40 ears were evaluated. The mean age of the patients aged 20–55 was 36.25 ± 9.06 years. Tympanograms of all ears were type A and none of them had middle ear pathology before and after COVID-19. The time of performing pure-tone audiometry before COVID-19 was between 1 and 12 months, and after COVID-19, it was between 3 and 12 months. Half of the patients (10 patients) included in this study presented with loss of smell and taste. Other complaints of the patients were as follows fatigue in eight patients, sore throat in five patients, cough in five patients, tinnitus in four patients, fever in four patients, headache in four patients, dizziness in three patients, joint pain in three patients, back pain in two patients, ear fullness in two patients, hearing loss in one patient. The patient, who described hearing loss during COVID-19, was evaluated six months after COVID-19. This patient had no complaints and her hearing thresholds were normal. No statistically significant difference was found between the bone conduction pure-tone thresholds measured before and after COVID-19 at all frequencies (500 Hz, p = 0,482; 1000 Hz, p = 0,147; 2000 Hz, p = 0,057; 4000 Hz, p = 0,063). Fig. 1 shows the bone conduction pure-tone audiometric thresholds for both pre- and post-COVID-19 groups. Similarly, there was no statistically significant difference between the air conduction pure-tone thresholds between 1000 Hz and 8000 Hz frequencies before and after COVID-19 (1000 Hz, p = 0,069; 2000 Hz, p = 0,406; 4000 Hz, p = 0,900; 8000 Hz, p = 0,131). However, better hearing thresholds were determined after COVID-19 at 250 and 500 Hz frequencies in air conduction pure-tone thresholds. The mean air conduction pure-tone hearing thresholds before and after COVID-19 at a frequency of 250 Hz were 16 and 11.62, respectively (p = 0,000). At 500 Hz, it was 14.37 and 11.12, respectively (p = 0,001). Fig. 2 shows the air conduction pure-tone audiometric thresholds for both pre- and post-COVID-19 groups. The average value of mean bone conduction thresholds at 500 Hz, 1000 Hz, 2000 Hz was 8.16 ± 5.74 and 9.37 ± 5.5 (p = 0,121) before and after COVID-19, respectively. The average values of the mean air conduction thresholds were 14.41 ± 5.92 and 12.37 ± 6.96 (p = 0,018) before and after COVID-19. Fig. 3 shows audiograms of mean thresholds at each frequency obtained before and after COVID-19.
Fig. 1

The bone conduction pure-tone audiometric thresholds for both pre- and post-COVID-19 groups.

Fig. 2

The air conduction pure-tone audiometric thresholds for both pre- and post-COVID-19 groups.

Fig. 3

The audiograms of mean thresholds at each frequency obtained before and after COVID-19.

The bone conduction pure-tone audiometric thresholds for both pre- and post-COVID-19 groups. The air conduction pure-tone audiometric thresholds for both pre- and post-COVID-19 groups. The audiograms of mean thresholds at each frequency obtained before and after COVID-19. Thirteen of the patients used only favipiravir treatment for five days, 1600 mg twice a day on the first day and 600 mg twice a day on the following days. In addition to favipiravir treatment, two patients used hydroxychloroquine treatment, 200 mg twice a day, for five days. Five patients did not receive any drug treatment. When the pre- and post-COVID-19 bone conduction hearing thresholds of 15 patients using favipiravir treatment were compared, no significant difference was found in all frequencies (500 Hz, p = 0,879; 1000 Hz, p = 0,284; 2000 Hz, p = 0,134; 4000 Hz, p = 0,120).

Discussion

The studies conducted during the COVID-19 pandemic show that SARS-CoV-2 infection affects the central nervous system, peripheral nervous system and muscle. Headache, decreased responsiveness, anosmia, hyposmia, hypogeusia and dysgeusia are common central nervous system symptoms of coronavirus infection. The rare cases where COVID-19 infection affects the peripheral nervous system and muscles are Guillain-Barré syndrome, Miller Fisher syndrome, polyneuritis cranialis and rhabdomyolysis. Studies suggest that the neurological findings of the SARS-CoV-2 virus have a direct neurotropic effect and a secondary effect of the virus [13], [14]. Although it is still unknown how the virus affects the audiovestibular system, the literature on the subject is expanding. In Mustafa's study, which consisted of 20 asymptomatic COVID-19 patients, it was shown that hearing was affected especially at high frequencies (4000–8000 Hz) and a significant decrease was found in transient evoked otoacoustic emission (TEOAE) thresholds. The researcher claimed that CoV-2, like other neurotropic viruses, caused viral damage in the organ of Corti and hair cells, which was shown by the effect in the otoacoustic emission results [15]. In another study, worse mean hearing thresholds were found in hospitalized COVID-19 patients at high frequencies from 1000 Hz than the control group [16]. Apart from these studies, literature data on the relationship between COVID-19 and the auditory system are mostly case reports. Sriwijitalai and Wiwanitkit reported the first reported case of sensorineural hearing loss in an elderly individual with COVID-19 in the literature [17]. In another study, otalgia, tinnitus and unilateral conductive hearing loss in a patient with COVID-19 were reported [18]. Kılıç et al. stated that the PCR test was positive in one of the five patients who came to the clinic with the diagnosis of sudden hearing loss during the COVID-19 process [19]. Karimi-Galougahi et al. also reported six cases of unilateral sensorineural hearing loss associated with COVID-19 disease [20]. In our study, in which mild COVID-19 patients who were administered outpatient treatment were evaluated, we showed that SARS-CoV-2 had no bad effect on hearing values. Unlike other studies in the literature, the patients' own audiometry values were used as control. We found better mean air conduction hearing thresholds at 250 Hz and 500 Hz frequencies after COVID-19 although a statistically significant difference was found at these frequencies. We thought that this might be because hearing thresholds were made by different audiologists at different times. The fact that there is a difference between the mean air conduction pure-tone hearing thresholds before and after COVID-19 at both frequencies (250–500 Hz) is not more than 5 dB supports our claim. Hydroxychloroquine and favipiravir used in the treatment of COVID-19 may show potential ototoxic side effects. It has been reported in the literature that unilateral or bilateral hearing loss or tinnitus may develop due to the use of these drugs [21]. In our study, 13 of 20 patients used favipiravir alone and two used favipiravir plus hydroxychloroquine treatment. Five patients did not use any drug treatment for COVID-19. When the pre- and post-COVID-19 hearing thresholds of 15 patients receiving favipiravir treatment were compared, no statistically significant difference was found. In conclusion, we found that the use of favipiravir had no effect on hearing thresholds in patients with mild COVID-19 disease who were not hospitalized. This study has limitations, such as the small number of patients. Pre-COVID-19 audiometry and post-COVID-19 audiometry were not performed by the same audiologist, and the lack of standardization between pre- and post-COVID-19 audiometry times was the other limitation. Also, the absence of patients' otoacoustic emissions and speech audiometry were other limitations. However, we should note that none of the patients in this study reported a difference in their pre- and post-COVID-19 hearing levels makes these limitations partially unimportant. In conclusion, although we did not detect the effects of SARS-CoV-2 on the hearing thresholds in patients with non-hospitalized mild COVID-19 disease, our study is a preliminary one. Further studies are needed to investigate the possible effects of SARS-CoV-2 on the auditory system.

Funding

There are no funding sources.

CRediT authorship contribution statement

Osman Durgut: Conceptualization, Methodology, Formal analysis, Investigation, Resources, Data curation, Writing - Original draft, Supervision, Project administration. Mesut Karataş: Investigation, Data curation, Resources, Writing - review & editing. Çağlar Çelik: Investigation, Data curation, Resources, Writing - review & editing. Oğuzhan Dikici: Writing - review & editing, Supervision, Project administration. Fevzi Solmaz: Supervision, Project administration. Sündüz Gencay: Supervision, Project administration.

Declaration of competing interest

Osman Durgut, M.D. declares that he has no conflicts of interest. Mesut Karataş, M.D. declares that he has no conflicts of interest. Çağlar Çelik, M.D. declares that he has no conflicts of interest. Oğuzhan Dikici, M.D. declares that he has no conflicts of interest. Fevzi Solmaz, M.D. declares that he has no conflicts of interest. Sündüz Gencay, M.D. declares that he has no conflicts of interest.
  20 in total

1.  Does coronavirus affect the audio-vestibular system? A rapid systematic review.

Authors:  Ibrahim Almufarrij; Kai Uus; Kevin J Munro
Journal:  Int J Audiol       Date:  2020-06-12       Impact factor: 2.117

2.  Don't forget ototoxicity during the SARS-CoV-2 (Covid-19) pandemic!

Authors:  Andrea Ciorba; Virginia Corazzi; Piotr Henryk Skarżyński; Magdalena B Skarżyńska; Chiara Bianchini; Stefano Pelucchi; Stavros Hatzopoulos
Journal:  Int J Immunopathol Pharmacol       Date:  2020 Jan-Dec       Impact factor: 3.219

3.  Hearing loss and COVID-19: A note.

Authors:  Won Sriwijitalai; Viroj Wiwanitkit
Journal:  Am J Otolaryngol       Date:  2020-04-02       Impact factor: 1.808

4.  SARS-CoV-2 and hearing: An audiometric analysis of COVID-19 hospitalized patients.

Authors:  Francisco Alves de Sousa; Rodrigo Pinto Costa; Sandra Xará; Ana Nóbrega Pinto; Cecília Almeida E Sousa
Journal:  J Otol       Date:  2021-02-03

Review 5.  Viral causes of hearing loss: a review for hearing health professionals.

Authors:  Brandon E Cohen; Anne Durstenfeld; Pamela C Roehm
Journal:  Trends Hear       Date:  2014-07-29       Impact factor: 3.293

Review 6.  The neurology of COVID-19 revisited: A proposal from the Environmental Neurology Specialty Group of the World Federation of Neurology to implement international neurological registries.

Authors:  Gustavo C Román; Peter S Spencer; Jacques Reis; Alain Buguet; Mostafa El Alaoui Faris; Sarosh M Katrak; Miguel Láinez; Marco Tulio Medina; Chandrashekhar Meshram; Hidehiro Mizusawa; Serefnur Öztürk; Mohammad Wasay
Journal:  J Neurol Sci       Date:  2020-05-07       Impact factor: 3.181

7.  Features of anosmia in COVID-19.

Authors:  T Klopfenstein; N J Kadiane-Oussou; L Toko; P-Y Royer; Q Lepiller; V Gendrin; S Zayet
Journal:  Med Mal Infect       Date:  2020-04-17       Impact factor: 2.152

8.  A Novel Coronavirus from Patients with Pneumonia in China, 2019.

Authors:  Na Zhu; Dingyu Zhang; Wenling Wang; Xingwang Li; Bo Yang; Jingdong Song; Xiang Zhao; Baoying Huang; Weifeng Shi; Roujian Lu; Peihua Niu; Faxian Zhan; Xuejun Ma; Dayan Wang; Wenbo Xu; Guizhen Wu; George F Gao; Wenjie Tan
Journal:  N Engl J Med       Date:  2020-01-24       Impact factor: 91.245

9.  Could sudden sensorineural hearing loss be the sole manifestation of COVID-19? An investigation into SARS-COV-2 in the etiology of sudden sensorineural hearing loss.

Authors:  Osman Kilic; Mahmut Tayyar Kalcioglu; Yasemin Cag; Ozan Tuysuz; Emel Pektas; Hulya Caskurlu; Ferihan Cetın
Journal:  Int J Infect Dis       Date:  2020-06-12       Impact factor: 3.623

Review 10.  The neurological manifestations of COVID-19: a review article.

Authors:  Hamid Reza Niazkar; Behdad Zibaee; Ali Nasimi; Narjes Bahri
Journal:  Neurol Sci       Date:  2020-06-01       Impact factor: 3.830

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.