Literature DB >> 34917450

Colon capsule for panendoscopy: a narrow window of opportunity.

Emanuele Rondonotti1, Marco Pennazio2.   

Abstract

Entities:  

Year:  2021        PMID: 34917450      PMCID: PMC8670997          DOI: 10.1055/a-1548-6572

Source DB:  PubMed          Journal:  Endosc Int Open        ISSN: 2196-9736


× No keyword cloud information.
The first capsule endoscopy system available in the market was named M2A (M2A Capsule, GivenImaging Ltd, Yokneam, Israel) 1 . This acronym reveals the philosophy behind this technology: the implementation of a miniaturized system allowing to endoscopically evaluate the entire digestive system, ideally from the mouth to the anus (which is what M2A stands for). The technical barriers that had initially prevented the exploration of the entire surface of the digestive system have been removed over time through the development of batteries with longer life, the optimization of power consumption (e. g., through the adaptive frame rate) and the increase in the number of cameras and in the angle of view (to cover the entire mucosal surface of wider lumen organs). The study by Vuik et al. 2 in the current issue of Endoscopy International Open, as well as several other publications, 3 confirm that the endoscopic study of the entire surface of the digestive system appears to be now technically possible. However, does “technical feasible” also mean “clinically reliable”? Although the very quick small bowel transit time reported in the present study (median small bowel transit time: 47’) might negatively impact on small bowel capsule diagnostic yield, the key role of capsule endoscopy in the evaluation of the small bowel mucosa has been confirmed in several studies, and current guidelines endorse the use of this device as first-line examination in many clinical scenarios 4 . The clinical reliability concerns, therefore, are related mostly to the evaluation of the colonic, esophageal, and gastric mucosa, which would be the potential added value of panenteroscopy. In standard colonoscopy, there is a well-documented correlation between the degree of cleanliness and diagnostic performance 5 . This is likely to have even greater relevance in the field of wireless endoscopy, where the capsule is purely passive (e. g., it cannot wash or remove debris) and bowel preparation also plays a key role in promoting device propulsion. In the paper from Vuik et al. 2 the rate of patients with adequate colon cleansing (76.6 %) was below the ≥ 90 % minimum standard recommended for optical colonoscopy 6 , although involved subjects were healthy and highly compliant with the preparation schedule (93.6 % of them took the entire bowel preparation). Although this may reflect the specific preparation schedule adopted in the study, a recent systematic review 3 showed that the rate of patients with adequate colon cleansing was highly variable, but ≥ 90 % in only 54 % of studies, even when different schedules were used. Furthermore, although no formal standard quality measure exists, the rate of patients with adequate cleansing of the whole gastrointestinal tract (52.8 %) is far from being acceptable. Finally, as far as the completion rate for colon evaluation is concerned, the 51 % rate reported by Vuik et al. 2 is similar to those reported in other publications 7 8 9 and far below the recommended threshold of 90 % 6 . Although relevant gastric findings, missed by previous traditional gastroscopy, were reported in patients undergoing small bowel capsule endoscopy 10 , the parameter for assessing the efficacy of panenteroscopy in evaluation of gastric mucosa (observation of more than 90 % of the mucosa) appears to be arbitrary, contrived, and very difficult to measure. In the absence of a traditional examination as comparator, no clinically relevant conclusions can be drawn about the diagnostic yield in the stomach of such a non-steerable capsule. In addition, because the capsule was ingested without a dedicated protocol for esophageal inspection 11 , the Z line was identified in fewer than 50 % of the subjects included in the study, underscoring that capsule endoscopy, when administered as a panenteroscopy tool, cannot represent a viable alternative to regular gastroscopy. Patient acceptability has always been emphasized as one of the major advantages of capsule endoscopy over more invasive and less tolerated procedures, such as gastroscopy and colonoscopy. However, Vuik et al. 2 demonstrated that moving from theory (pre-procedural questionnaire) to practice (post-procedural questionnaire), patient expectations are somewhat disregarded. In line with these results, in the TOPAZ study 12 more subjects who underwent both procedures under evaluation unexpectedly preferred traditional colonoscopy over colon capsule endoscopy. Once again, the major determinant behind this preference was the burden related to colon capsule endoscopy bowel preparation. Taking into account all these issues, one might wonder if panenteric capsule endoscopy evaluation is a journey worth undertaking and a goal worth pursuing. Taken individually, each traditional endoscopic examination for evaluation of esophagus, stomach and colon seems to be more reliable than panenteroscopy. However, the latter offers the unique opportunity to combine evaluation of several segments of the digestive tract at the same time, in a single examination. This becomes particularly relevant when the “timing of the procedure” or “disease extent” are key factors. Indeed, there is growing evidence supporting the use of a panenteroscopic approach in patients with digestive bleeding, in whom an upper digestive tract lesion has been excluded 13 14 . Initial data suggest that in these patients, a timely panenteric evaluation has relevant clinical (increased rate of diagnosis, crucial information for therapeutic work-up) as well as organizational/economic consequences (reduction of the number of unnecessary examinations and hospitalization time). Similarly, for staging and surveillance in patients with Crohn's disease, especially in the pediatric setting, panenteroscopy appears to be a reliable tool for assessing disease mucosal activity and extent, compared to more invasive methods 15 16 17 . In light of all the pros and cons, with current technology and organizational/practical issues (e. g. the preparation schedule), the window of opportunity for panenteroscopy in everyday clinical practice currently is narrow. However, the most limiting factors appear amenable to significant improvements, and the introduction of automated image analysis systems (e. g. artificial intelligence-based software) 18 , which could make the procedure even easier and more reliable, is expected soon. These improvements are needed before implementing use of the capsule for whole-intestine mucosal assessment in clinical practice.
  17 in total

1.  Artificial intelligence in small bowel capsule endoscopy - current status, challenges and future promise.

Authors:  Xavier Dray; Dimitris Iakovidis; Charles Houdeville; Rodrigo Jover; Dimitris Diamantis; Aymeric Histace; Anastasios Koulaouzidis
Journal:  J Gastroenterol Hepatol       Date:  2021-01       Impact factor: 4.029

2.  A new panenteric capsule endoscopy-based strategy in patients with melena and a negative upper gastrointestinal endoscopy: a prospective feasibility study.

Authors:  Alessandro Mussetto; Rosario Arena; Lorenzo Fuccio; Margherita Trebbi; Alessandra Tina Garribba; Stefano Gasperoni; Ilaria Manzi; Omero Triossi; Emanuele Rondonotti
Journal:  Eur J Gastroenterol Hepatol       Date:  2021-05-01       Impact factor: 2.566

3.  Performance measures for lower gastrointestinal endoscopy: a European Society of Gastrointestinal Endoscopy (ESGE) Quality Improvement Initiative.

Authors:  Michal F Kaminski; Siwan Thomas-Gibson; Marek Bugajski; Michael Bretthauer; Colin J Rees; Evelien Dekker; Geir Hoff; Rodrigo Jover; Stepan Suchanek; Monika Ferlitsch; John Anderson; Thomas Roesch; Rolf Hultcranz; Istvan Racz; Ernst J Kuipers; Kjetil Garborg; James E East; Maciej Rupinski; Birgitte Seip; Cathy Bennett; Carlo Senore; Silvia Minozzi; Raf Bisschops; Dirk Domagk; Roland Valori; Cristiano Spada; Cesare Hassan; Mario Dinis-Ribeiro; Matthew D Rutter
Journal:  Endoscopy       Date:  2017-03-07       Impact factor: 10.093

4.  Small-bowel capsule endoscopy and device-assisted enteroscopy for diagnosis and treatment of small-bowel disorders: European Society of Gastrointestinal Endoscopy (ESGE) Clinical Guideline.

Authors:  Marco Pennazio; Cristiano Spada; Rami Eliakim; Martin Keuchel; Andrea May; Chris J Mulder; Emanuele Rondonotti; Samuel N Adler; Joerg Albert; Peter Baltes; Federico Barbaro; Christophe Cellier; Jean Pierre Charton; Michel Delvaux; Edward J Despott; Dirk Domagk; Amir Klein; Mark McAlindon; Bruno Rosa; Georgina Rowse; David S Sanders; Jean Christophe Saurin; Reena Sidhu; Jean-Marc Dumonceau; Cesare Hassan; Ian M Gralnek
Journal:  Endoscopy       Date:  2015-03-31       Impact factor: 10.093

5.  A novel PillCam Crohn's capsule score (Eliakim score) for quantification of mucosal inflammation in Crohn's disease.

Authors:  Rami Eliakim; Doron Yablecovitch; Adi Lahat; Bella Ungar; Eyal Shachar; Dan Carter; Limor Selinger; Sandra Neuman; Shomron Ben-Horin; Uri Kopylov
Journal:  United European Gastroenterol J       Date:  2020-03-12       Impact factor: 4.623

6.  A simplified ingestion procedure for esophageal capsule endoscopy: initial evaluation in healthy volunteers.

Authors:  I M Gralnek; R Rabinovitz; D Afik; R Eliakim
Journal:  Endoscopy       Date:  2006-09       Impact factor: 10.093

7.  A Treat to Target Strategy Using Panenteric Capsule Endoscopy in Pediatric Patients With Crohn's Disease.

Authors:  Salvatore Oliva; Marina Aloi; Franca Viola; Saverio Mallardo; Fortunata Civitelli; Francesca Maccioni; Cesare Hassan; Paola Papoff; Salvatore Cucchiara; Stanley A Cohen
Journal:  Clin Gastroenterol Hepatol       Date:  2018-10-13       Impact factor: 11.382

8.  Inadequate Boston Bowel Preparation Scale scores predict the risk of missed neoplasia on the next colonoscopy.

Authors:  Matthew A Kluge; J Lucas Williams; Connie K Wu; Brian C Jacobson; Paul C Schroy; David A Lieberman; Audrey H Calderwood
Journal:  Gastrointest Endosc       Date:  2017-06-23       Impact factor: 9.427

9.  Non-small-bowel lesions identification by capsule endoscopy: A single centre retrospective study.

Authors:  Tommaso Innocenti; Gabriele Dragoni; Jenny Roselli; Giuseppe Macrì; Tommaso Mello; Stefano Milani; Andrea Galli
Journal:  Clin Res Hepatol Gastroenterol       Date:  2020-03-31       Impact factor: 2.947

10.  Panenteric capsule endoscopy identifies proximal small bowel disease guiding upstaging and treatment intensification in Crohn's disease: A European multicentre observational cohort study.

Authors:  Foong Way D Tai; Pierre Ellul; Alfonso Elosua; Ignacio Fernandez-Urien; Gian E Tontini; Luca Elli; Rami Eliakim; Uri Kopylov; Sara Koo; Clare Parker; Simon Panter; Reena Sidhu; Mark McAlindon
Journal:  United European Gastroenterol J       Date:  2021-03-19       Impact factor: 4.623

View more
  1 in total

1.  Light flickering through a narrow window opening in capsule panendoscopy.

Authors:  Pablo Cortegoso Valdivia; Ervin Toth; Anastasios Koulaouzidis
Journal:  Endosc Int Open       Date:  2022-05-13
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.