Literature DB >> 34915911

Positive end-expiratory pressure in COVID-19 acute respiratory distress syndrome: the heterogeneous effects.

Davide Chiumello1,2,3, Matteo Bonifazi4, Tommaso Pozzi5, Paolo Formenti4, Giuseppe Francesco Sferrazza Papa5,6, Gabriele Zuanetti5, Silvia Coppola4.   

Abstract

BACKGROUND: We hypothesized that as CARDS may present different pathophysiological features than classic ARDS, the application of high levels of end-expiratory pressure is questionable. Our first aim was to investigate the effects of 5-15 cmH2O of PEEP on partitioned respiratory mechanics, gas exchange and dead space; secondly, we investigated whether respiratory system compliance and severity of hypoxemia could affect the response to PEEP on partitioned respiratory mechanics, gas exchange and dead space, dividing the population according to the median value of respiratory system compliance and oxygenation. Thirdly, we explored the effects of an additional PEEP selected according to the Empirical PEEP-FiO2 table of the EPVent-2 study on partitioned respiratory mechanics and gas exchange in a subgroup of patients.
METHODS: Sixty-one paralyzed mechanically ventilated patients with a confirmed diagnosis of SARS-CoV-2 were enrolled (age 60 [54-67] years, PaO2/FiO2 113 [79-158] mmHg and PEEP 10 [10-10] cmH2O). Keeping constant tidal volume, respiratory rate and oxygen fraction, two PEEP levels (5 and 15 cmH2O) were selected. In a subgroup of patients an additional PEEP level was applied according to an Empirical PEEP-FiO2 table (empirical PEEP). At each PEEP level gas exchange, partitioned lung mechanics and hemodynamic were collected.
RESULTS: At 15 cmH2O of PEEP the lung elastance, lung stress and mechanical power were higher compared to 5 cmH2O. The PaO2/FiO2, arterial carbon dioxide and ventilatory ratio increased at 15 cmH2O of PEEP. The arterial-venous oxygen difference and central venous saturation were higher at 15 cmH2O of PEEP. Both the mechanics and gas exchange variables significantly increased although with high heterogeneity. By increasing the PEEP from 5 to 15 cmH2O, the changes in partitioned respiratory mechanics and mechanical power were not related to hypoxemia or respiratory compliance. The empirical PEEP was 18 ± 1 cmH2O. The empirical PEEP significantly increased the PaO2/FiO2 but also driving pressure, lung elastance, lung stress and mechanical power compared to 15 cmH2O of PEEP.
CONCLUSIONS: In COVID-19 ARDS during the early phase the effects of raising PEEP are highly variable and cannot easily be predicted by respiratory system characteristics, because of the heterogeneity of the disease.
© 2021. The Author(s).

Entities:  

Keywords:  COVID-19; Respiratory distress syndrome; Respiratory mechanics; SARS-CoV-2; Ventilator-induced lung injury

Mesh:

Substances:

Year:  2021        PMID: 34915911      PMCID: PMC8674862          DOI: 10.1186/s13054-021-03839-4

Source DB:  PubMed          Journal:  Crit Care        ISSN: 1364-8535            Impact factor:   9.097


Background

The infection with severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) is characterized by an acute hypoxemic respiratory failure ranging from a mild to a severe form requiring intensive care admission and invasive mechanical ventilation in up of 30% of the severe forms of the disease [1, 2]. Based on the available body of evidence in order to limit the ventilator induced lung injury (VILI), not-related-to-COVID-19-ARDS patients are currently managed by applying low tidal volume without overcoming an inspiratory plateau pressure of 30 cmH2O and moderate–high PEEP levels in the moderate–severe forms [3-5]. However, it has also been shown that among ARDS patients similar PEEP levels should not be used, but an individualization is required because the response to PEEP differs according to the respiratory mechanics, hemodynamic, lung recruitability and shunt. Inappropriately too high PEEP levels might promote lung overstress, increase in alveolar dead space and hemodynamic impairment amplifying the VILI [6, 7]. At the present time, no randomized clinical trials which examined the effect of PEEP in COVID-19 ARDS patients (CARDS) have been published [8]. The surviving sepsis campaign on the management of CARDS recommended a higher PEEP strategy rather than lower PEEP strategy [9]. A subsequent consensus of an international panel of experts did not reach any agreement on the PEEP level, suggesting that PEEP should be titrated according to a PEEP/FiO2 table or to obtain the best respiratory compliance or the lowest driving pressure [10]. In a large extensive review of the literature the mean applied PEEP level was between 10 and 16 cmH2O [8]. However, CARDS patients may present different characteristics from the ARDS, especially in the early phase [11]. CARDS patients may show a discrepancy between a relatively high respiratory system compliance, higher amount of lung gas volume and severity of hypoxemia [11-13]. Lung autopsy in patients who died from CARDS showed a diffuse alveolar damage with significant endotheliitis and microthrombi in the pulmonary vessels [13-16]. In particular, the alteration of perfusion into the lung could be due to an alteration in the hypoxic vasoconstriction (hyperperfusion in the poorly ventilated lung regions) and to a lower perfusion in the aerated lung regions rather than a lung collapse [16]. Consequently, if the vascular derangement is the major mechanism related to hypoxemia, the use of moderate–high PEEP levels is questionable. Consequently, we hypothesized that as CARDS may present different pathophysiological features than classic ARDS, the application of high levels of end-expiratory pressure is questionable. Our first aim was to investigate the effects of 5–15 cmH2O of PEEP on partitioned respiratory mechanics, gas exchange and dead space; secondly, we investigated whether respiratory system compliance and severity of hypoxemia could affect the response to PEEP on partitioned respiratory mechanics, gas exchange and dead space, dividing the population according to the median value of respiratory system compliance and oxygenation. Thirdly, we explored the effects of an additional PEEP selected according to the Empirical PEEP-FiO2 table of the EPVent-2 study on partitioned respiratory mechanics and gas exchange in a subgroup of patients.

Methods

Study population

Sixty-one mechanically ventilated patients with a confirmed diagnosis of SARS-CoV-2 admitted to the general intensive care of the ASST Santi Paolo Carlo, Milan, Italy, were enrolled. Inclusion criteria were a laboratory confirmation of SARS-CoV-2 infection based on positive reverse transcriptase–polymerase chain reaction (RT-PCR) assay and diagnosis of ARDS, the day of the study. Exclusion criteria were the presence of barotrauma, the history of severe chronic obstructive pulmonary disease and the hemodynamic instability. The study was approved by the local ethical committee (Comitato Etico Milano Area I; 2020/ST/095) and informed consent was obtained according to Italian regulations.

Study protocol

This was an observational study in which two levels of PEEP were tested. A lung CT scan was performed during an end-expiratory pressure at 5 cmH2O of PEEP. All patients deeply sedated and paralyzed were ventilated in volume control with a tidal volume of 6–8 ml/kg of predicted body weight. Respiratory rate and inspiratory oxygen fraction were selected to maintain a pH and an arterial saturation between 7.34 and 7.44 and 88 and 95%, respectively. A PEEP level of 10 cmH2O was clinically set at the beginning in all the patients during the stabilization period (60 min). Subsequently, a recruitment maneuver was applied in pressure control ventilation with a PEEP of 5 cmH2O to reach 45 cmH2O of inspiratory plateau pressure with a respiratory rate of 10 for two minutes [17]. Keeping constant the tidal volume, respiratory rate and oxygen fraction, two PEEP levels (5 and 15 cmH2O) were selected. Measurements are collected after 20 min of stabilization. The patients underwent the PEEP test in stable hemodynamic conditions. In addition, in a subgroup of 29 patients, the PEEP was adjusted according to the table named Empirical PEEP-FiO2 of the EPVent-2 study [18]. The selected PEEP was called the “Empirical PEEP,” and for safety reason it was titrated to limit a maximum of 35 cmH2O of inspiratory plateau airway pressure (Additional file 1: Fig. 1S).

Data collection

Twenty minutes after the application of the selected PEEP arterial/venous blood gas, lung mechanics and hemodynamic were collected. An end-inspiratory and end-expiratory pause were performed to measure the airway and esophageal pressure changes.

Gas exchange, respiratory mechanics and lung CT data

In order to measure the esophageal pressure, a radio-opaque balloon catheter (SmartCath Bicore, USA) was positioned in the lowest part of the esophagus and connected to a pressure transducer. The esophageal catheter was inflated of air with 1.5 mL and introduced transorally to reach the stomach at a depth between 50 and 55 cm from the mouth [19]. The intragastric position was confirmed by a rise in intra-abdominal pressure following external manual epigastric compression. Then, it was retracted into the esophagus (i.e., confirmed by the presence of cardiac artifacts in the pressure tracing and by the difference in the absolute pressure) at a distance between 35 and 40 cm from the mouth [19]. During an end-expiratory occlusion by compressing the thorax, the concordant changes of airway and esophageal pressure were verified to check the correct position of the balloon. The amount of gas in the balloon was periodically checked throughout the experiment. The ventilatory ratio and the estimated physiological dead space were computed according to classic equations (See Additional File 1). The right-to-left intrapulmonary shunt was calculated accordingly to the venous admixture equation, using the blood gas values obtained from the central venous catheter as a surrogate of the mixed venous blood values [20]. The respiratory system, lung, chest wall elastance and lung stress were computed according to the standard formulas (see Additional File 1). The mechanical power was calculated based on a mathematical simplification of the original mechanical power for volume control-ventilated patients [21]: The mechanical power was normalized to the respiratory system compliance [22]. The total lung weight, gas volume and the proportions of the different compartments (not inflated, poorly inflated, well inflated and overinflated) were computed with dedicated software (Maluna) [17].

Statistical analysis

Continuous data are presented as mean and standard deviation or median and interquartile range, as appropriate, while categorical data are reported as frequencies and percentage. A One-way ANOVA or Friedman test for repeated measure among the levels of PEEP was used to account for the repeated measures design; in case of statistical significance, Holm–Sidak test or Tukey’s test were used, respectively. Characteristics of the patients as well as the differences in respiratory mechanics, gas exchange between the two groups “high PaO2/FiO2” and “low PaO2/FiO2” or between “high Compliance” or “low Compliance” were compared by the Student’s t-test or Wilcoxon–Mann–Whitney rank sum test, as appropriate. The chi-square test or Fisher’´s exact test of independence to analyze for frequency count. A p value of 0.05 or less was considered statistically significant. The statistical analysis was performed with SigmaPlot 11.0 (Systat Software, San Jose, CA) and RStudio (R Foundation for Statistical Computing, Vienna, Austria).

Results

The main characteristics of the patients are presented in Additional file 1: Table 1S. The days between the onset of symptoms and hospital admission were 6 [5-8]. The median PaO2/FiO2 at baseline was 113 [79-158] mmHg (15.1 [10.5–21.1] kPa). Thirty-eight patients (62%) and 19 patients (31%) presented a severe and moderate form of CARDS. The mean lung gas volume and weight were 1441 [923-2235] mL and 1348 [946-1647] g, respectively; the amount of not aerated tissue was 10.7 [3.1–19.1] % of the total lung weight (Additional file 1: Table 1S).

Response to 5–15 cmHO of PEEP on partitioned respiratory mechanics, gas exchange and dead space

In Table 1 the data of the respiratory mechanics and gas exchange at 5 and 15 cmH2O of PEEP are presented. At 15 cmH2O of PEEP the lung elastance, lung stress and mechanical power were significantly higher compared to 5 cmH2O. Although the airway plateau pressure was significantly higher at 15 cmH2O, the driving pressure and elastance of respiratory system increased but did not reach statistical significance (Fig. 1; Additional file 1: Fig. 2S).
Table 1

Respiratory mechanics and gas exchange within 5 and 15 cmH2O of PEEP

VariablesPEEP 561 patientsPEEP 1561 patientsp
Plateau pressure, cmH2O17 ± 328 ± 3< 0.001
Driving pressure, cmH2O12 ± 313 ± 30.071
Respiratory system elastance, cmH2O/L23 [19–27]24 [21–31]0.093
Lung elastance, cmH2O/L18 [15–22]19 [17–25]0.049
Chest wall elastance, cmH2O/L5 [3–6]4 [3–6]0.845
Lung stress, cmH2O13.1 ± 3.122.3 ± 4.0 < 0.001
Mechanical power, J/min16.7 ± 5.726.1 ± 6.4 < 0.001
Mechanical Power_Compliancers, J/min/(mL/cmH2O)0.36 [0.27–0.50]0.61 [0.51–0.77] < 0.001
PaO2, mmHg63 [55–76]84 [74–99] < 0.001
PaO2/FiO2, mmHg82 [66–138]127 [90–184] < 0.001
Right-to-left shunt, %47 ± 1535 ± 12 < 0.001
PvO2, mmHg42 ± 747 ± 7 < 0.001
ScvO2, %74 ± 879 ± 6 < 0.001
Ca-vO2, mL2.8 [2.3–3.2]3.0 [2.4–3.4]0.024
PaCO2, mmHg48 ± 950 ± 9 < 0.001
Ventilatory ratio1.66 ± 0.391.74 ± 0.370.002
Estimated physiological dead space0.50 [0.43–0.58]0.52 [0.42–0.60] < 0.001

Paired T-test or Wilcoxon–Mann–Whitney test for repeated measures were performed, as appropriate. Tidal volume and respiratory rate were unchanged between the two PEEP levels. Ca-vO2: arterial–venous oxygen content difference; Compliancers: respiratory system compliance; ScvO2 central oxygen venous saturation; PvO2 mixed venous oxygen tension

Fig. 1

Respiratory system, chest wall and lung elastance at 5 and 15 cmH2O of PEEP of the whole population. *p < 0.05; ns: not significant

Respiratory mechanics and gas exchange within 5 and 15 cmH2O of PEEP Paired T-test or Wilcoxon–Mann–Whitney test for repeated measures were performed, as appropriate. Tidal volume and respiratory rate were unchanged between the two PEEP levels. Ca-vO2: arterial–venous oxygen content difference; Compliancers: respiratory system compliance; ScvO2 central oxygen venous saturation; PvO2 mixed venous oxygen tension Respiratory system, chest wall and lung elastance at 5 and 15 cmH2O of PEEP of the whole population. *p < 0.05; ns: not significant Concerning gas exchange, the PaO2/FiO2, arterial carbon dioxide and ventilatory ratio significantly increased at 15 cmH2O of PEEP. The arterial–venous oxygen difference and central venous saturation were significantly higher at 15 cmH2O of PEEP. The shunt significantly decreased at 15 cmH2O of PEEP. Increasing PEEP from 5 to 15 cmH2O the mechanics and gas exchange variables that significantly increased showed high heterogeneity.

Response to 5–15 cmHO of PEEP according to the compliance of respiratory system and severity of hypoxemia

Considering the median of respiratory compliance of the whole population (44 ml/cmH2O) to separate the population in a high and a low compliance group, the first group had a higher lung gas volume and well inflated lung tissue (Additional file 1: Table 2S; Fig. 3S). The oxygenation and ventilatory ratio were not different (Additional file 1: Table 2S). By increasing the PEEP from 5 to 15 cmH2O, the changes in the partitioned respiratory system elastance and gas exchange were similar between the two groups (Table 2, Additional file 1: Fig. 5S).
Table 2

Changes in respiratory mechanics and gas exchange at 5 and 15 cmH2O of PEEP between high and low respiratory system compliance group

VariablesLow Crs < 44 mL/cmH2O30 patientsHigh Crs≥ 44 mL/cmH2O31 patientsp
Δ15-5 Plateau pressure, cmH2O10 [7–12]11 [10–13]0.042
Δ15-5 Driving pressure, cmH2O0 [− 3 to 2]1 [0–3]0.042
Δ15-5 Respiratory system elastance, cmH2O/L− 1 [− 5 to 4]2 [0–6]0.057
Δ15-5 Lung elastance, cmH2O/L2 [− 2 to 5]2 [0–5]0.286
Δ15-5 Chest wall elastance, cmH2O/L0 [− 2 to 2]0 [− 1 to 0]0.305
Δ15-5 Lung stress, cmH2O9 [6–11]9 [8–12]0.256
Δ15-5 Mechanical power, J/min9 [8–12]9 [8–11]0.866
Δ15-5 Mechanical Power_Compliancers, J/min/(mL/cmH2O)0.26 [0.12–0.40]0.23 [0.16–0.35]0.656
Δ15-5 PaO2, mmHg20 [13–38]20 [6–30]0.336
Δ15-5 PaO2/FiO2, mmHg28 [16–51]30 [10–50]0.657
Δ15-5 Right-to-left shunt, %− 12 [− 23 to − 1]− 9 [− 18 to − 5]0.710
Δ15-5 PvO2, mmHg4.0 [2.3–8.8]2.0 [1.0–8.1]0.219
Δ15-5 ScvO2, %5.5 [1.0–10.8]2.5 [0.0–8.1]0.184
Δ15-5 Ca-vO2, mL1.0 [0.3–1.7]0.6 [0.2–1.3]0.331
Δ15-5 PaCO2, mmHg1 [− 1 to 3]2 [1–4]0.226
Δ15-5 Ventilatory ratio0.04 [− 0.10 to 0.10]0.08 [0.02–0.20]0.119
Δ15-5 Estimated physiological dead space0.01 [− 0.01 to 0.03]0.02 [0.01–0.05]0.119

T-test or Wilcoxon–Mann–Whitney test were performed, as appropriate. Δ15-5: difference between 15 and 5 cmH2O of PEEP; Ca-vO2: arterial–venous oxygen content difference; Compliancers: respiratory system compliance; ScvO2 central oxygen venous saturation; PvO2 mixed venous oxygen tension

Changes in respiratory mechanics and gas exchange at 5 and 15 cmH2O of PEEP between high and low respiratory system compliance group T-test or Wilcoxon–Mann–Whitney test were performed, as appropriate. Δ15-5: difference between 15 and 5 cmH2O of PEEP; Ca-vO2: arterial–venous oxygen content difference; Compliancers: respiratory system compliance; ScvO2 central oxygen venous saturation; PvO2 mixed venous oxygen tension Furthermore, we also divided the whole population according to the median of the PaO2/FiO2 (81.8 mmHg or 10.9 kPa), in high and low PaO2/FiO2 groups. The two groups presented similar lung gas volume, not inflated tissue and partitioned respiratory mechanics (Additional file 1: Table 3S; Fig. 4S). By increasing the PEEP from 5 to 15 cmH2O, the changes in partitioned respiratory mechanics and mechanical power were similar (Table 3, Additional file 1: Fig. 6S).
Table 3

Changes in respiratory mechanics and gas exchange at 5 and 15 cmH2O of PEEP between high and low PaO2/FiO2 group

VariablesLowPaO2/FiO2 < 81.831 patientsHighPaO2/FiO2 ≥ 81.830 patientsp
Δ15-5 Plateau pressure, cmH2O8 [10–11]11 [10–13]0.147
Δ15-5 Driving pressure, cmH2O0 [− 2 to 1]1 [0–3]0.147
Δ15-5 Respiratory system elastance, cmH2O/L0 [− 3 to 3]3 [0–6]0.126
Δ15-5 Lung elastance, cmH2O/L2 [− 2 to 4]3 [1–7]0.257
Δ15-5 Chest wall elastance, cmH2O/L0 [− 2 to 1]0 [− 2 to 2]0.373
Δ15-5 Lung stress, cmH2O9 [7–11]9 [8–13]0.534
Δ15-5 Mechanical power, J/min9 [8–11]10 [9–11]0.351
Δ15-5 Mechanical Power_Compliancers, J/min/(mL/cmH2O)0.21 [0.12–0.34]0.30 [0.17–0.37]0.436
Δ15-5 PaO2, mmHg26 [16–38]16 [4–23]0.012
Δ15-5 PaO2/FiO2, mmHg31 [16–55]28 [9–42]0.212
Δ15-5 Right-to-left shunt, %− 16 [− 26 to − 10]0 [− 11 to 0] < 0.001
Δ15-5 PvO2, mmHg3 [2–11]1 [0–2] < 0.001
Δ15-5 ScvO2, %8.5 [4.4–13.4]0.6 [− 1 to 3] < 0.001
Δ15-5 Ca-vO2, mL1.3 [0.9–1.8]0.4 [0.0–0.6] < 0.001
Δ15-5 PaCO2, mmHg1 [− 2 to 3]2 [1–5]0.110
Δ15-5 Ventilatory ratio0.04 [− 0.09 to 0.10]0.08 [− 0.02 to 0.19]0.065
Δ15-5 Estimated physiological dead space0.01 [− 0.02 to 0.03]0.02 [0.01–0.05]0.070

T-test or Wilcoxon–Mann–Whitney test were performed, as appropriate. Δ15-5: difference between 15 and 5 cmH2O of PEEP; Ca-vO2: arterial–venous oxygen content difference; Compliancers: respiratory system compliance; ScvO2 central oxygen venous saturation; PvO2 mixed venous oxygen tension

Changes in respiratory mechanics and gas exchange at 5 and 15 cmH2O of PEEP between high and low PaO2/FiO2 group T-test or Wilcoxon–Mann–Whitney test were performed, as appropriate. Δ15-5: difference between 15 and 5 cmH2O of PEEP; Ca-vO2: arterial–venous oxygen content difference; Compliancers: respiratory system compliance; ScvO2 central oxygen venous saturation; PvO2 mixed venous oxygen tension

Response to Empirical PEEP on partitioned respiratory mechanics, gas exchange and dead space

In a subgroup of 29 patients the Empirical PEEP has been selected according to the PEEP/FIO2 table. The Empirical PEEP was 18 ± 1 cmH2O. The Empirical PEEP significantly increased the driving pressure, elastance, lung stress and mechanical power compared to 15 cmH2O of PEEP (Additional file 1: Table 4S; Fig. 7S). At the Empirical PEEP the PaO2/FiO2 was higher compared to 15 cmH2O of PEEP, while carbon dioxide and ventilatory ratio were similar.

Discussion

The main findings of this study evaluating different PEEP levels, with constant tidal volume, were: (1) 15 cmH2O of PEEP significantly increased the ventilatory ratio, lung elastance and mechanical power although with heterogeneous responses, (2) the arterial oxygenation increased by increasing the PEEP, (3) the compliance of the respiratory system and the level of hypoxemia at baseline did not affect the PEEP response and (4) the PEEP suggested by the PEEP/FiO2 table was higher than 15 cmH2O. Most mechanically ventilated CARDS patients fulfill the criteria of ARDS according to the Berlin definition [23, 24]. Typically, ARDS is characterized by an inflammatory pulmonary edema, shunt related hypoxemia and reduction both in lung gas volume and in the respiratory compliance [6]. Higher PEEP levels, recruitment maneuvers and prone positioning are suggested to recruit the lung [4, 7]. However, COVID-19 is a systemic disease which besides affecting mainly the lung, can also damage the vascular endothelium [13, 17]. It has been reported an activation of the coagulation cascade with an associated micro–macro thrombosis in the lung. It has also been found the presence of vessels enlargement in the ground glass opacities, suggesting the presence of a thrombotic inflammatory process [16]. The available data clearly indicate that CARDS can present heterogeneous characteristics with a relatively high respiratory system compliance [11, 12, 25–27]. Our group proposed the presence of two phenotypes in CARDS based on lung mechanics properties, type L (low elastance) and type H (high elastance) [28, 29]. In the present study our population had a median of 2 [2] days of mechanical ventilation since intubation and the PEEP trial, presented a median compliance of respiratory system of 44 ml/cmH2O. Similar data were also reported by other groups [25, 30, 31]. In a recent review, the compliance values at 1 SD above the mean or the 75th percentile > 50 ml/cmH2O were reported in 43% of the studies [8]. Similarly, the lung gas volume computed by CT was also considerable high, a median of 2952 [2038-3617] mL, contrary to previous data on ARDS patients in which the lung gas volume (i.e., baby lung) was typically reduced [17, 32, 33]. In a recent review analyzing the available data about mechanical ventilation setting in CARDS, it was reported that PEEP values ranged from 9 to 16.5 cmH2O [8]. The PEEP was selected mainly according to the change in oxygenation or to a PEEP/FiO2 table [34, 35]. In this study we choose to evaluate the effects of two different PEEP levels (5 and 15 cmH2O) based on previous studies which defined as “low” and “moderate–high” PEEP [17, 36]. The higher PEEP levels significantly increased the oxygenation and reduced the alveolar shunt. However, at the same time, in the majority of patients the ventilatory ratio was higher indicating a less efficiently CO2 clearance (i.e., higher dead space) as well as the respiratory system compliance decreased. Similar data was also found by Mauri et al. in a small group of CARDS (10 patients), in which 15 cmH2O of PEEP was associated with a better oxygenation and higher arterial carbon dioxide [25]. In patients with ARDS it has been observed that increasing PEEP the arterial oxygenation increased by a reduction in the intrapulmonary shunt with also an increase in the dead space [37]. More importantly, in our patients the increase of PEEP significantly increased the arterial–venous difference in oxygenation and the central venous oxygenation. Thus, the ameliorating in oxygenation at higher PEEP levels seems more related to the modification of the ventilation/perfusion ratio in the lung areas with low ventilation/perfusion rather than a lung recruitment (i.e., reopening of collapsed lung regions) [11]. The reduction in the alveolar shunt could also be due to a decrease in cardiac output by the higher levels of PEEP [37-39]. Although the plateau airway pressure and driving pressure are commonly used as surrogate of the VILI, the real distending force of the lung is the transpulmonary pressure [4, 40, 41]. The transpulmonary pressure computed by the esophageal balloon technique is closely related to the lung stress [41, 42]. Thus, in the present study we assessed both the lung elastance and the lung stress. The enrolled patients have a relatively normal chest wall elastance which contributes to the elastance of the respiratory system by approximately 20–30% [41]. By note, at higher PEEP levels the lung elastance and lung stress were significantly higher. In a previous small study, applying the electrical impedance tomography technique (EIT), higher PEEP levels were associated with higher lung elastance and to higher lung overdistension evaluated by EIT technique [43]. In addition to evaluate the overall effect of different levels of PEEP, we computed the mechanical power which depends on the driving pressure, tidal volume, respiratory rate and PEEP. The respiratory rate and tidal volume did not change throughout the study; thus, the mechanical power resulted from the interaction of PEEP and driving pressure. By increasing PEEP, the mechanical power and the normalized mechanical power for the compliance of respiratory system (i.e., to take into account the size of the lung) were much higher compared to low PEEP level. In ARDS patients several studies evaluated the possible factors associated with PEEP response [4, 6]. We found a comparable median response to PEEP in both patients with a low and high respiratory system compliance and with high and low PaO2/FiO2 in whom the oxygenation improved, the mechanical power significantly increased while the ventilatory ratio and respiratory mechanics, although deteriorating, showed high heterogeneity. Perier et al., comparing two CARDS subgroups based on the compliance of the respiratory system assessed at low PEEP level, found a similar behavior in terms of collapse, hyperdistention and oxygenation by applying a range of PEEP from 6 to 18 cmH2O [44]. In our population, the more hypoxemic group, which seems to improve the oxygenation when PEEP was increased from 5 to 15 cmH2O, showed the same quantitative radiological features at the CT scan at 5 cmH2O compared with less hypoxemic group. This can partially explain that the changes in the partitioned respiratory system elastance and gas exchange were similar between the two groups. Similarly, the group with low and high respiratory system compliance presented the same amount of not and poorly inflated tissue, with similar changes in the partitioned respiratory system elastance and gas exchange between the two groups. In ARDS patients the use of PEEP-FiO2 tables is a quite common approach in clinical practice mainly due to the greater ease of application [4]. Several PEEP-FiO2 tables have been proposed over the decades [4, 6]. In two ARDS randomized clinical trials that compared a lower and higher PEEP-FiO2 table, the arterial oxygenation increased with the higher PEEP table, suggesting a higher lung recruitment a better outcome [6]. In ARDS patients the PEEP-FiO2 table was able to provide PEEP levels according to the lung recruitability [7]. In the present study applying a PEEP-FiO2 combination table commonly suggested in ARDS, the proposed average PEEP level was 18 ± 1 cmH2O. However, this Empirical PEEP level was associated with a significantly higher oxygenation but to a worsening in ventilatory ratio and lung elastance compared to 15 cmH2O. Tsolaki et al., applying the ARDS net protocol, according to the Surviving sepsis campaign, found that the suggested PEEP level was 18 cmH2O instead of a mean level of 8 cmH2O of PEEP, when the best combination of respiratory system compliance, CO2 clearance and hemodynamic was used [45]. In a small study of 15 CARDS comparing the PEEP selected by the EIT technique to obtain to the best compromise between lung collapse and overdistension, with PEEP/FiO2 table approach, the latter suggested higher PEEP (17 vs 12 cmH2O) [46]. Thus, if we followed in CARDS the Empirical PEEP-FiO2 table, significantly higher PEEP levels should have been applied in lungs with almost normal compliance with possible detrimental consequences. This study has several strengths: Firstly, it is the first study which computed the lung compliance and mechanical power during the change of PEEP; secondly, it evaluated two PEEP levels (low and moderate/high) compared to an Empirical PEEP-FiO2 table, which is suggested in ARDS patients.

Limitations

The possible limitations of this study were the absence of any data regarding the computation of lung recruitability at 15 cmH2O of PEEP and regarding the changes of cardiac output at the different PEEP levels.

Conclusions

In conclusion, the main finding of this study evaluating different PEEP levels with constant tidal volume was that the effects of raising PEEP are highly variable among CARDS patients and cannot easily be predicted by respiratory system characteristics, because of the heterogeneity of the disease, including with respect to respiratory system compliance and hypoxia that is mainly due to low V/Q respond less than to true shunt. Moreover, the PEEP adjusted according to the Empirical PEEP-FiO2 table resulted in an unnecessary much higher PEEP levels possibly which was not related to the pathophysiology of CARDS patients. Moderate PEEP levels are able to redistribute the pulmonary blood flow, ameliorate oxygenation and avoid the lung over stress and strain and the impairment of cardiac function with a higher need of fluids and vasopressor. Thus, in CARDS tailoring PEEP based on a “PEEP test,” represents an invaluable option to set a protective lung ventilation and prevent further damage to the lungs. Additional file 1. Respiratory mechanics and physiological variables formulas; study protocol flow-chart; baseline characteristics table; additional data about PEEP 5-15cmH2O comparison; boxplot and linear regression graphs.
  45 in total

1.  Lung recruitment in patients with the acute respiratory distress syndrome.

Authors:  Luciano Gattinoni; Pietro Caironi; Massimo Cressoni; Davide Chiumello; V Marco Ranieri; Michael Quintel; Sebastiano Russo; Nicolò Patroniti; Rodrigo Cornejo; Guillermo Bugedo
Journal:  N Engl J Med       Date:  2006-04-27       Impact factor: 91.245

2.  Baseline Characteristics and Outcomes of 1591 Patients Infected With SARS-CoV-2 Admitted to ICUs of the Lombardy Region, Italy.

Authors:  Giacomo Grasselli; Alberto Zangrillo; Alberto Zanella; Massimo Antonelli; Luca Cabrini; Antonio Castelli; Danilo Cereda; Antonio Coluccello; Giuseppe Foti; Roberto Fumagalli; Giorgio Iotti; Nicola Latronico; Luca Lorini; Stefano Merler; Giuseppe Natalini; Alessandra Piatti; Marco Vito Ranieri; Anna Mara Scandroglio; Enrico Storti; Maurizio Cecconi; Antonio Pesenti
Journal:  JAMA       Date:  2020-04-28       Impact factor: 56.272

3.  Severe covid-19 pneumonia: pathogenesis and clinical management.

Authors:  Amy H Attaway; Rachel G Scheraga; Adarsh Bhimraj; Michelle Biehl; Umur Hatipoğlu
Journal:  BMJ       Date:  2021-03-10

4.  Impact of initial respiratory compliance in ventilated patients with acute respiratory distress syndrome related to COVID-19.

Authors:  Florent Laverdure; Amélie Delaporte; Astrid Bouteau; Thibaut Genty; François Decailliot; François Stéphan
Journal:  Crit Care       Date:  2020-07-09       Impact factor: 9.097

5.  Endothelial cell infection and endotheliitis in COVID-19.

Authors:  Zsuzsanna Varga; Andreas J Flammer; Peter Steiger; Martina Haberecker; Rea Andermatt; Annelies S Zinkernagel; Mandeep R Mehra; Reto A Schuepbach; Frank Ruschitzka; Holger Moch
Journal:  Lancet       Date:  2020-04-21       Impact factor: 79.321

6.  PEEP levels in COVID-19 pneumonia.

Authors:  Vasiliki Tsolaki; Ilias Siempos; Eleni Magira; Stelios Kokkoris; George E Zakynthinos; Spyros Zakynthinos
Journal:  Crit Care       Date:  2020-06-06       Impact factor: 9.097

Review 7.  Respiratory support in patients with acute respiratory distress syndrome: an expert opinion.

Authors:  Davide Chiumello; Laurent Brochard; John J Marini; Arthur S Slutsky; Jordi Mancebo; V Marco Ranieri; B Taylor Thompson; Laurent Papazian; Marcus J Schultz; Marcelo Amato; Luciano Gattinoni; Alain Mercat; Antonio Pesenti; Daniel Talmor; Jean-Louis Vincent
Journal:  Crit Care       Date:  2017-09-12       Impact factor: 9.097

8.  COVID-19 Does Not Lead to a "Typical" Acute Respiratory Distress Syndrome.

Authors:  Luciano Gattinoni; Silvia Coppola; Massimo Cressoni; Mattia Busana; Sandra Rossi; Davide Chiumello
Journal:  Am J Respir Crit Care Med       Date:  2020-05-15       Impact factor: 21.405

9.  Surviving Sepsis Campaign: guidelines on the management of critically ill adults with Coronavirus Disease 2019 (COVID-19).

Authors:  Waleed Alhazzani; Morten Hylander Møller; Yaseen M Arabi; Mark Loeb; Michelle Ng Gong; Eddy Fan; Simon Oczkowski; Mitchell M Levy; Lennie Derde; Amy Dzierba; Bin Du; Michael Aboodi; Hannah Wunsch; Maurizio Cecconi; Younsuck Koh; Daniel S Chertow; Kathryn Maitland; Fayez Alshamsi; Emilie Belley-Cote; Massimiliano Greco; Matthew Laundy; Jill S Morgan; Jozef Kesecioglu; Allison McGeer; Leonard Mermel; Manoj J Mammen; Paul E Alexander; Amy Arrington; John E Centofanti; Giuseppe Citerio; Bandar Baw; Ziad A Memish; Naomi Hammond; Frederick G Hayden; Laura Evans; Andrew Rhodes
Journal:  Intensive Care Med       Date:  2020-03-28       Impact factor: 17.440

10.  Computed tomography assessment of PEEP-induced alveolar recruitment in patients with severe COVID-19 pneumonia.

Authors:  Lorenzo Ball; Chiara Robba; Lorenzo Maiello; Jacob Herrmann; Sarah E Gerard; Yi Xin; Denise Battaglini; Iole Brunetti; Giuseppe Minetti; Sara Seitun; Antonio Vena; Daniele Roberto Giacobbe; Matteo Bassetti; Patricia R M Rocco; Maurizio Cereda; Lucio Castellan; Nicolò Patroniti; Paolo Pelosi
Journal:  Crit Care       Date:  2021-02-24       Impact factor: 9.097

View more
  4 in total

1.  Capnodynamic monitoring of lung volume and blood flow in response to increased positive end-expiratory pressure in moderate to severe COVID-19 pneumonia: an observational study.

Authors:  Luis Schulz; Antony Stewart; William O'Regan; Peter McCanny; Danielle Austin; Magnus Hallback; Mats Wallin; Anders Aneman
Journal:  Crit Care       Date:  2022-07-31       Impact factor: 19.334

Review 2.  COVID-19-Related ARDS: Key Mechanistic Features and Treatments.

Authors:  John Selickman; Charikleia S Vrettou; Spyros D Mentzelopoulos; John J Marini
Journal:  J Clin Med       Date:  2022-08-20       Impact factor: 4.964

3.  Chest wall loading during supine and prone position in patients with COVID-19 ARDS: effects on respiratory mechanics and gas exchange.

Authors:  Michele Umbrello; Sergio Lassola; Andrea Sanna; Rocco Pace; Sandra Magnoni; Sara Miori
Journal:  Crit Care       Date:  2022-09-13       Impact factor: 19.334

4.  Association of radiological lung pattern and respiratory mechanics with potential for lung recruitment in patients with COVID-ARDS: a retrospective cohort study.

Authors:  Hans-Jörg Gillmann; Carolin Jung; Milan Speth; Jens Vogel-Claussen; Thomas Stueber
Journal:  Eur J Med Res       Date:  2022-10-01       Impact factor: 4.981

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.