Literature DB >> 34915402

Foot kinematics and leg muscle activation patterns are altered in those with limited ankle dorsiflexion range of motion during incline walking.

Yujin Kwon1, Gwanseob Shin2.   

Abstract

BACKGROUND: Larger ankle dorsiflexion (DF) is required when walking on inclined surfaces. Individuals with limited DF range of motion (ROM) may experience greater tissue stress on sloped surfaces and walk in altered gait patterns compared to the those with normal DF ROM. RESEARCH QUESTION: Would the individuals with limited DF ROM walk with distinctive ankle DF patterns compared to those with normal DF ROM on the inclined surfaces?
METHODS: Ten Limited DF ROM (passive ROM=35.3 ± 2.7°) and nine Normal DF ROM (passive ROM=46.4 ± 4.2°) participants walked on a treadmill at five slope angles (0°, 5°, 10°, 15°, 20°) for 2 min at a self-selected speed. The peak DF angles and the peak myoelectric activity levels of the tibialis anterior (TA) and soleus (SOL) muscles were quantified during the swing and stance phases of each walking trial, and they were compared between the two groups.
RESULTS: Participants with limited DF ROM walked with smaller peak DF (3.1° at 0° slope ~ 8.4° at 20° slope) and greater peak TA activity in swing than those of the Normal ROM participants (3.4° ~ 12.2°), with significant differences at 20° slope. The peak DF angle in stance (Limited: 9.6° ~ 19.0°; Normal: 10.1° ~ 21.0°) did not differ between the two groups at all slopes, but the peak activity of the SOL muscle was significantly greater for the Limited group at slopes of 10° and higher. SIGNIFICANCE: Study results indicate that incline walking could be more challenging to the individuals with limited DF ROM as they need to approach and push-off the sloped surfaces with more efforts of the dorsiflexor and the plantar flexor muscles, respectively. Prolonged walking on inclined surfaces may produce faster development of muscle fatigue or tissue damage than those with normal DF ROM.
Copyright © 2021 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Ankle; Dorsiflexion; Incline walking; Muscle activity; Passive torque; Range of motion

Mesh:

Year:  2021        PMID: 34915402     DOI: 10.1016/j.gaitpost.2021.12.002

Source DB:  PubMed          Journal:  Gait Posture        ISSN: 0966-6362            Impact factor:   2.840


  1 in total

1.  Differences between Systems Using Optical and Capacitive Sensors in Treadmill-Based Spatiotemporal Analysis of Level and Sloping Gait.

Authors:  Dimitris Mandalidis; Ioannis Kafetzakis
Journal:  Sensors (Basel)       Date:  2022-04-05       Impact factor: 3.576

  1 in total