| Literature DB >> 34915255 |
Tong Wang1, Ning Wang1, Na Li1, Xiaorui Ji1, Hongwei Zhang2, Dianyu Yu3, Liqi Wang4.
Abstract
In this study, an emulsion stabilized by soy protein isolate (SPI)-pectin (PC) complexes was prepared to investigate the effects of high-intensity ultrasound (HIU) treatment (150-600 W) on the physicochemical properties, microstructure, and stability of emulsions. The results found that the emulsion treated at 450 W showed the best emulsion stability index (ESI) (25.18 ± 1.24 min), the lowest particle size (559.82 ± 3.17 nm), the largest ζ-potential absolute value (16.39 ± 0.18 mV), and the highest adsorbed protein content (27.31%). Confocal laser scanning microscopy (CLSM) and atomic force microscopy (AFM) revealed that the emulsion aggregation was significantly improved by ultrasound treatment, and the average roughness value (Rq) was the smallest (10.3 nm) at 450 W. Additionally, HIU treatment reduced the interfacial tension and apparent viscosity of the emulsion. Thermal stability was best when the emulsion was treated at 450 W, D43 was minimal (907.95 ± 31.72 nm), and emulsion separation also improved. Consequently, the creaming index (CI) was significantly decreased compared to the untreated sample, indicating that the storage stability of the emulsion was enhanced.Entities:
Keywords: Emulsion; High-intensity ultrasound; Pectin; Soy protein isolate; Stability
Mesh:
Substances:
Year: 2021 PMID: 34915255 PMCID: PMC8683769 DOI: 10.1016/j.ultsonch.2021.105871
Source DB: PubMed Journal: Ultrason Sonochem ISSN: 1350-4177 Impact factor: 7.491
Fig. 1Emulsifying properties analysis under different ultrasound powers Note: The superscript letters in the same group indicate significant differences among the data (p < 0.05).
Changes of mean particle size (D43), PDI and ζ-potential of emulsion treated by high intensity ultrasound under different powers.
| Ultrasound power (W) | D43 (nm) | PDI | ζ-potential |
|---|---|---|---|
| 0 | 1706.00 ± 6.46 a | 0.801 ± 0.098 a | −8.55 ± 0.32 a |
| 150 | 1142.20 ± 4.66 b | 0.349 ± 0.039 bc | −11.47 ± 0.25 b |
| 300 | 834.87 ± 5.78 c | 0.263 ± 0.064 c | −13.11 ± 0.47 c |
| 450 | 559.82 ± 3.17 e | 0.265 ± 0.045 c | −16.39 ± 0.18 e |
| 600 | 638.80 ± 6.53 d | 0.433 ± 0.072 b | −15.71 ± 0.22 d |
Note: The different superscript letters in the same column indicate significant differences between the data (p < 0.05).
Fig. 2CLSM and particle distribution under different ultrasound powers.
Fig. 3Interfacial proteins distribution under different ultrasound powers Note: The superscript letters in the same group indicate significant differences among the data (p < 0.05).
Fig. 4AFM analysis under different ultrasound powers.
Fig. 5Contact angle and interfacial tension analysis under different ultrasound powers.
Fig. 6Apparent viscosity analysis under different ultrasound powers.
Fig. 7Thermal stability analysis under different ultrasound powers.
Fig. 8Storage stability analysis under different ultrasound powers.
Fig. 9Mechanism of HIU effect on the SPI-PC emulsion.