Gary Sh Cheung1, Kent Cy So1, Christy Ky Chan1, Anna Ky Chan1, Alex Pui-Wai Lee1, Yat-Yin Lam2, Bryan P Yan1. 1. Division of Cardiology, Department of Medicine and Therapeutics, Faculty of Medicine, The Chinese University of Hong Kong and Prince of Wales Hospital, Hong Kong SAR, China. 2. Center Medical, Suite 1201, Central Building, Central, Hong Kong SAR, China.
Abstract
AIMS: We aimed to compare long-term "real-world" outcomes of three left atrial appendage occlusion (LAAO) devices for stroke prevention in a Chinese population with non-valvular atrial fibrillation (NVAF). METHODS AND RESULTS: Consecutive patients who underwent LAAO from June 2009 to October 2016 at a university-affiliated hospital were retrospectively analysed. In-hospital and major adverse events (MAE) including mortality, stroke and major bleeding rates were compared by LAAO device. One hundred and sixty-one (161) patients (mean age 71.4±8.2 years; 67.7% male) with mean CHA2DS2-VASc score of 4.1±1.6 and HAS-BLED score of 2.9±1.1 underwent 162 LAAO procedures, of which 47.5% (n=77), 41.4% (n=67) and 11.1% (n=18) were AMPLATZER Cardiac Plug (ACP)/Amulet, WATCHMAN and LAmbre, respectively. The procedural success rate was 97.5% (158/162). The in-hospital adverse event rate was 7.4% (12/162) and comparable among devices (p=NS). Mean follow-up duration was 28.3±24.4 months (373 patient-years). There were no significant differences in long-term MAE rates among devices (p=NS). Observed annual ischaemic stroke (1.1% vs. 5.1%, p<0.001) and major bleeding rates (2.7% vs. 4.5%, p=NS) were lower compared with the predicted rates, respectively. CONCLUSIONS: The WATCHMAN, ACP/Amulet and LAmbre LAAO devices demonstrated similar long-term safety and efficacy in prevention of ischaemic stroke and major bleeding in patients with NVAF.
AIMS: We aimed to compare long-term "real-world" outcomes of three left atrial appendage occlusion (LAAO) devices for stroke prevention in a Chinese population with non-valvular atrial fibrillation (NVAF). METHODS AND RESULTS: Consecutive patients who underwent LAAO from June 2009 to October 2016 at a university-affiliated hospital were retrospectively analysed. In-hospital and major adverse events (MAE) including mortality, stroke and major bleeding rates were compared by LAAO device. One hundred and sixty-one (161) patients (mean age 71.4±8.2 years; 67.7% male) with mean CHA2DS2-VASc score of 4.1±1.6 and HAS-BLED score of 2.9±1.1 underwent 162 LAAO procedures, of which 47.5% (n=77), 41.4% (n=67) and 11.1% (n=18) were AMPLATZER Cardiac Plug (ACP)/Amulet, WATCHMAN and LAmbre, respectively. The procedural success rate was 97.5% (158/162). The in-hospital adverse event rate was 7.4% (12/162) and comparable among devices (p=NS). Mean follow-up duration was 28.3±24.4 months (373 patient-years). There were no significant differences in long-term MAE rates among devices (p=NS). Observed annual ischaemic stroke (1.1% vs. 5.1%, p<0.001) and major bleeding rates (2.7% vs. 4.5%, p=NS) were lower compared with the predicted rates, respectively. CONCLUSIONS: The WATCHMAN, ACP/Amulet and LAmbre LAAO devices demonstrated similar long-term safety and efficacy in prevention of ischaemic stroke and major bleeding in patients with NVAF.
Authors: Vivek Y Reddy; Horst Sievert; Jonathan Halperin; Shephal K Doshi; Maurice Buchbinder; Petr Neuzil; Kenneth Huber; Brian Whisenant; Saibal Kar; Vijay Swarup; Nicole Gordon; David Holmes Journal: JAMA Date: 2014-11-19 Impact factor: 56.272
Authors: Wen-Hua Li; Duo Huang; Chern-En Chiang; Chu-Pak Lau; Hung-Fat Tse; Esther W Chan; Ian C K Wong; Gregory Y H Lip; Pak-Hei Chan; Chung-Wah Siu Journal: Clin Cardiol Date: 2016-11-28 Impact factor: 2.882
Authors: A Pieter Kappetein; Stuart J Head; Philippe Généreux; Nicolo Piazza; Nicolas M van Mieghem; Eugene H Blackstone; Thomas G Brott; David J Cohen; Donald E Cutlip; Gerrit-Anne van Es; Rebecca T Hahn; Ajay J Kirtane; Mitchell W Krucoff; Susheel Kodali; Michael J Mack; Roxana Mehran; Josep Rodés-Cabau; Pascal Vranckx; John G Webb; Stephan Windecker; Patrick W Serruys; Martin B Leon Journal: J Am Coll Cardiol Date: 2012-10-09 Impact factor: 24.094
Authors: David R Holmes; Saibal Kar; Matthew J Price; Brian Whisenant; Horst Sievert; Shephal K Doshi; Kenneth Huber; Vivek Y Reddy Journal: J Am Coll Cardiol Date: 2014-07-08 Impact factor: 24.094
Authors: Lucas V A Boersma; Boris Schmidt; Timothy R Betts; Horst Sievert; Corrado Tamburino; Emmanuel Teiger; Evgeny Pokushalov; Stephan Kische; Thomas Schmitz; Kenneth M Stein; Martin W Bergmann Journal: Eur Heart J Date: 2016-01-27 Impact factor: 29.983