Mamak Adel1, Zahra Salmani2, Navid Youssefi3, Behrouz Heidari4. 1. Dept. of Endodontics, Dental Caries Prevention Research Center, Qazvin University of Medical Sciences, Qazvin, Iran. 2. Dept. of Periodontics, Faculty of Dentistry, Alborz University of Medical Sciences, Karaj, Iran. 3. Postgraduate Student of Prosthodontics, Student Research Committee, Qazvin University of Medical Sciences, Qazvin, Iran. 4. Postgraduate Student of Endodontics, Student Research Committee, Qazvin University of Medical Sciences, Qazvin, Iran.
The process of dentin formation and root development stops when an immature tooth undergoes pulp necrosis. Resultantly, the root canal walls remain thin, and the apex remains open.
In such cases, it is imperative to close the apex by artificially inducing the formation of a calcified barrier to allow condensation of root filling materials and improve apical seal.
Inadequate apical seal is the most important reason for failure of non-surgical root canal treatment [ 1
]. Apexification is a commonly used technique to induce the closure of apical foramen in necrotic immature teeth. Single-session apexification by use of an apical plug and formation
of an artificial barrier is an alternative to multi-session apexification with calcium hydroxide. In this technique, biocompatible materials are used to create an apical seal and
allow root canal filling [ 1
].Mineral trioxide aggregate (MTA) is among the dental materials proposed for this purpose. MTA has ideal properties such as optimal biocompatibility [ 2
], bacteriostatic activity [ 3
], favorable sealability of the root canal and perforation sites [ 4
] and the ability to set even in presence of blood [ 5
]. The success rate of endodontic treatment of open-apex teeth with a MTA apical plug is reportedly 95.5% [ 6
]. However, difficult application and condensation of MTA in the apical region is a drawback of using MTA for apical plug. Evidence shows that the technique of application of MTA is highly important [ 6
- 7
]. Indirect application of ultrasonic energy on an endodontic plugger has been recommended for MTA delivery into the root canal to enhance the condensation of MTA in the apical region
for formation of an apical plug [ 7
- 9
].Information regarding an ideal method for delivery and application of MTA into the canal is limited and controversial. Some studies have demonstrated that application of ultrasonic
energy during MTA application leads to void formation and results in a filling with lower density and homogeneity compared with manual condensation [ 10
- 11
]. On the other hand, some other studies have shown that condensation of MTA using ultrasonic energy provides higher compressive strength and higher surface microhardness of MTA
compared with manual condensation [ 9
, 12
]. Another studies indicated that indirect application of ultrasonic energy would improve the adaptation of MTA to dentinal walls [ 13
- 14
]. Basturk et al. [ 15
] discussed that the compressive strength of MTA, applied by using ultrasonic energy, had no significant difference with that in manual application technique.Considering the existing controversy in the literature regarding the preferred technique of application of MTA, and the significance of treatment of open-apex teeth,
this study aimed to compare the microleakage of MTA plug applied by the manual technique and indirect use of ultrasonic with different powers.
Materials and Method
This in vitro, experimental study evaluated 48 single-rooted, single-canal maxillary central incisors with closed apices and no caries, cracks or root curvature.
The selected teeth had been extracted due to different reasons such as hopeless periodontal prognosis.A total of 48 qualified teeth were randomly divided into four experimental (n=10) and four positive and negative control (n=2) groups. For the purpose of standardization,
the teeth were decoronated at the cementoenamel junction using a diamond disc and high-speed hand-piece such that 13±1mm of root length remained. Next, 3mm of the root apex was cut
perpendicular to the root by a straight carbide fissure bur (Teezkavan, Tehran, Iran) to eliminate the apical delta and standardize the canal apex (root length in all teeth was 10±1mm).
The root canals were cleaned and shaped using Peeso reamers #1, #2 and #3 (Dentsply Maillefer, Switzerland) 1mm longer than the working length and Peeso reamer#4 to the working length.
Divergent open apices were prepared as retrograde using ProFile (06/40; Dentsply Maillefer, Switzerland). For this purpose, the file was introduced into the canal as retrograde
by 16 mm to enlarge the root-end to 1.36 mm diameter [ 7
]. In order to ensure the correct diameter of the apical end, it was measured using a digital caliper (CD-6CS Digimatic Caliper; Mitutoyo Corp., Japan) with 0.01 mm accuracy.
Sodium hypochlorite (5.25%) was used to rinse the canals during instrumentation. Moreover, 17% EDTA (Ethylenediaminetetraacetic acid) (MD Cleanser; Meta Co., Korea) gel was used
for 3 minutes to eliminate the smear layer. The canals were then rinsed with 10 cc of distilled water. The canals were dried and the teeth were randomly divided into four experimental
(n=10) and four positive and negative control (n=2) groups. Four teeth in the positive control group underwent root-end preparation as explained above, but did not receive the MTA plug.
They were tested by the fluid filtration method. Of the four teeth in the negative control group, two received the apical plug with indirect ultrasonic technique and two received the
apical plug by the manual technique. Eventually, the root surfaces were coated with wax. To enhance the application of MTA plug and to better simulate the periapical resistance present
in the clinical setting, the teeth were mounted in holes created in a moist flower sponge. ProRoot MTA powder (Dentsply Maillefer, Switzerland) was mixed with sterile water in 3:1 ratio [ 16
] and delivered into the canal using a MTA gun (Dentsply Maillefer, Switzerland), and condensed at the apical end with 5 mm thickness.In all groups, application and condensation of MTA plug were performed in three steps by application of 2-, 2- and 1-mm thick layers. In group 1, the MTA plug was condensed
manually using an endodontic plugger. In group 2, after the application of each layer of MTA plug, it was condensed by indirect use of ultrasonic energy (Various750-NE134; NSK, Japan)
at minimum power level by touching the ultrasonic tip (P10 tip) with the plugger shaft without contacting the tooth walls for 2 s [ 11
, 14
, 17
]. In group 3, the MTA plug was condensed by indirect use of ultrasonic energy with the power level of 2.5 (medium) for 2 s. In group 4, the MTA plug was condensed by indirect use of
ultrasonic energy at maximum power level for 2 s. It should be noted that the ultrasonic device had minimum, 1, 2, 3, 4, and maximum power levels. Excess MTA on the walls was
removed using a #50 stainless steel K-file (Dentsply Maillefer, Switzerland). Immediately after placement of the MTA plug, a radiograph was obtained to ensure its adequate thickness,
absence of voids, and optimal adaptation to the canal walls. Next, moist paper points #80 (Ariadent, Tehran, Iran) were placed in the canals. The samples were incubated at 37° and 100% humidity
for 7 days. After setting of the MTA plug, the roots were removed from the sponge, and adequate hardness of MTA was ensured using a file. The amount of microleakage was quantified using
a fluid filtration model.The fluid filtration model used in this study was equipped with an air tank, which had a manometer for precise adjustment of pressure at 0.5 atmosphere. A specific plastic tube was
connected to the air source, and its end part was connected to an Erlenmeyer flask. Two holes were made in the lid of the Erlenmeyer flask, one for the entrance of air and the other
for immersion in fluid. A micropipette (0.1 cc) was fixed and its end was connected to a three-valve tube by a latex pipe (0.5 cm in diameter). The upper side of the three-valve tube
was connected to a syringe, which was used to create air bubbles through the micropipette. The lower side was used to connect the specimens. Microleakage in each specimen was recorded
in millimeters (mm) and converted to µL/min/cm H2O.Normal distribution of data was evaluated using the Shapiro-Wilk test. Since the data were not normally distributed and considering the presence of four independent groups,
the non-parametric Kruskal-Wallis test was applied to compare the groups regarding microleakage. The non-parametric Mann Whitney test was used for pairwise comparisons of the groups. p< 0.05 was
considered statistically significant.
Results
No microleakage was noted in the negative control group. Severe microleakage was noted through the apex of teeth in the positive control group. Table 1 shows the mean apical
microleakage of the experimental groups. Comparison of microleakage of the groups showed that the amount of microleakage in group 3 (medium ultrasonic power) had a significant
difference with that in group 1 (manual condensation) (p= 0.043). Furthermore, microleakage in group 4 (use of maximum ultrasonic power) had a significant difference with that in
group 1 (manual condensation) (p= 0.029). No significant difference was noted in microleakage of other groups (different ultrasonic power levels with each other and minimum ultrasonic
power and manual condensation) (p> 0.05).
Table 1
Mean microleakage of the four experimental groups
Groups
Number
Mean microleakage (µL/min/cm H2O)
Std. deviation
Use of ultrasonic energy with minimum power
10
21.65
1.82
Use of ultrasonic energy with medium power
10
17.95
6.92
Use of ultrasonic energy with maximum power
10
15.30
5.85
Manual condensation
10
27.10
8.69
Mean microleakage of the four experimental groups
Discussion
Provision of an apical barrier is imperative during cleaning and shaping of root canals to achieve optimal apical seal. In absence of an apical barrier, it would be difficult to
prevent the apical extrusion of root filling material and achieve an apical seal. In cases with apical root resorption, apical perforation and necrotic immature teeth, an apical constriction
does not exist. In such cases, in order to confine the root filling materials to the canal space, provision of an artificial apical barrier is imperative [ 18
]. Several materials have been proposed for use as apical plug by the researchers such as calcium hydroxide [ 19
], MTA [ 20
] and dentin chips [ 21
]. Of the suggested materials, MTA has a superior marginal adaptation and biocompatibility compared with other materials [ 22
]. Considering the reverse funnel shape of open-apex teeth, we standardized the divergent apical foramen as retrograde using ProFile [40/6%]
[ 23
]. Controversy exists regarding the adequate thickness of MTA apical plug [ 7
, 23
- 24
]. Nonetheless, most researchers have agreed on 5 mm thickness of apical plug [ 25
- 26
]. Thus, MTA apical plug with 5 mm thickness was applied in this study. In addition, the teeth were mounted in a moist sponge during filling of open-apex roots according to a study by Martin et al. [ 23
] in order to simulate the periapical tissue and prevent the apical extrusion of root filling material. Considering the previous observations [ 7
, 25
], we indirectly transferred the ultrasonic energy to an endodontic plugger for the condensation of MTA plug.Aminoshariae et al. [ 8
] showed that direct application of ultrasonic energy for condensation of MTA plug, compared with manual condensation by a plugger, increased voids and decreased the adaptation of root
filling materials to the canal walls. In this study, ultrasonic energy was indirectly transferred to a plugger after eliminating the smear layer by using EDTA. Araujo et al. [ 27
] demonstrated that indirect application of ultrasonic energy (for 2 seconds) following smear layer removal significantly improved the marginal adaptation while use of ultrasonic
energy without elimination of smear layer did not increase the marginal adaptation.Parashos et al. [ 17
] showed that MTA condensation using indirect ultrasonic energy for 2 seconds decreased the microleakage, porosities, and voids compared with manual condensation. Thus, according to this study,
increasing the duration of use of ultrasonic energy for more than 2 seconds for condensation of MTA plug would significantly increase the void formation and microleakage and decrease
the microhardness of MTA plug. Previous studies on the efficacy of ultrasonic energy for MTA condensation have assessed properties such as compressive strength, flexural strength,
marginal adaptation, density, and porosities [ 7
- 9
, 11
- 13
, 28
]. Nonetheless, limited studies have evaluated the effect of ultrasonic on microleakage of MTA plug [ 7
, 17
]. Previous studies used the dye penetration or bacterial leakage techniques for assessment of microleakage [ 14
, 25
]. In addition, microleakage can be assessed using different techniques such as fluid filtration and electrochemical method [ 29
]. The fluid filtration technique, employed in this study, is a reproducible quantitative method and does not destruct the tooth structure. This technique does not require a marker
or an indicator and therefore, does not have their related complications (such as size or pH). The results are recorded automatically and are highly accurate. Very small values are also recorded [ 29
].It seems that the transfer of ultrasonic vibrations through the plugger to the MTA would eliminate the voids between the particles and result in formation of a denser and more homogenous
MTA plug. On the other hand, it would minimize the gap between the MTA plug and root canal walls, which leads to eventual reduction in microleakage. Yeung et al. [ 30
] showed that using ultrasonic energy for MTA condensation compared with the manual technique increased the weight of MTA mass. Escribano-Escriva et al. [ 14
] indicated that indirect application of ultrasonic energy enhanced the adaptation of MTA plug to the canal walls. Araujo et al. [ 27
] and Friedl et al. [ 28
] stated that ultrasonic energy improved the marginal adaptation of MTA plug to the canal walls and increased its density. Lawley et al. [ 7
] assessed the apical seal provided by the MTA plug after its manual application and by the use of ultrasonic energy. They showed that indirect application of ultrasonic energy
with 50% power decreased the apical microleakage after the placement of MTA plug. We used minimum, medium, and maximum power levels of ultrasonic device. Although use of medium and high
ultrasonic power levels for MTA plug application decreased the microleakage compared with the manual technique (p= 0.043 and p= 0.029, respectively), use of ultrasonic energy with
minimum power level did not decrease the microleakage compared with the manual technique (p> 0.05). Thus, it seems that minimum ultrasonic power level is not sufficient for achieving
a homogenous mass with maximum adaptation to the canal walls, and higher power levels (medium and high) are required for this purpose.Basturk et al. [ 15
] used the power level 5 of ultrasonic energy for MTA condensation and measured its compressive strength compared with the compressive strength of manually condensed MTA plug.
They showed that the compressive strength of MTA applied by the use of ultrasonic energy was significantly higher than that applied manually. In the study by Basturk et al. [ 15
], indirect use of ultrasonic energy decreased the porosities and increased the compressive strength of MTA plug compared with the manual technique. However, this difference was
not significant. The difference between the results yielded by their study and ours can be due to the use of an impression to fabricate the MTA plug instead of root canal and long
duration of using ultrasonic energy (30 s) in their study. However, Yeung et al. [ 30
] used minimum power level of ultrasonic energy for condensation of MTA plug and concluded that the weight of MTA mass significantly increased when ultrasonic was used compared with
that when the manual technique was employed. Their results were different from ours, which may be due to the absence of standardization and absence of any information on minimum and
maximum power levels of ultrasonic device. El-Ma'aita et al. [ 10
] stated that use of manual technique resulted in a denser filling compared with the ultrasonic method. In addition, Ghasemi et al. [ 11
] reported that use of manual technique decreased the number of voids in the apical plug [ 11
]. Aminoshera et al. [ 8
] indicated that manual application resulted in superior homogeneity and fewer voids compared with the ultrasonic technique [ 8
]. The controversy between their results and ours can be due to the direct use of ultrasonic energy for a longer period of time (30 s) in their studies, which might result in
formation of air bubbles in the MTA mass and reduction in density compared with the use of manual technique for MTA condensation.
Conclusion
Considering the current results, it appears that application of MTA with indirect ultrasonic energy at medium or high power level would decrease the microleakage of MTA plug
in open-apex root canals. However, considering the results of this study and differences between our methodology and that of previous studies, it appears that determining the more
appropriate method for MTA plug application in the clinical setting requires further studies and standardization.
Conflict of Interest
The authors have no conflicts of interest to disclose.
Authors: Rebecca L Martin; Francesca Monticelli; William W Brackett; Robert J Loushine; Roy A Rockman; Marco Ferrari; David H Pashley; Franklin R Tay Journal: J Endod Date: 2007-01-04 Impact factor: 4.171
Authors: Yasser Alsayed Tolibah; Line Droubi; Saleh Alkurdi; Mohammad Tamer Abbara; Nada Bshara; Thuraya Lazkani; Chaza Kouchaji; Ibrahim Ali Ahmad; Ziad D Baghdadi Journal: Int J Environ Res Public Health Date: 2022-04-27 Impact factor: 4.614