Literature DB >> 34891672

Multistage Pruning of CNN Based ECG Classifiers for Edge Devices.

Li Xiaolin, Rajesh C Panicker, Barry Cardiff, Deepu John.   

Abstract

Using smart wearable devices to monitor patients' electrocardiogram (ECG) for real-time detection of arrhythmias can significantly improve healthcare outcomes. Convolutional neural network (CNN) based deep learning has been used successfully to detect anomalous beats in ECG. However, the computational complexity of existing CNN models prohibits them from being implemented in low-powered edge devices. Usually, such models are complex with lots of model parameters which results in large number of computations, memory, and power usage in edge devices. Network pruning techniques can reduce model complexity at the expense of performance in CNN models. This paper presents a novel multistage pruning technique that reduces CNN model complexity with negligible loss in performance compared to existing pruning techniques. An existing CNN model for ECG classification is used as a baseline reference. At 60% sparsity, the proposed technique achieves 97.7% accuracy and an F1 score of 93.59% for ECG classification tasks. This is an improvement of 3.3% and 9% for accuracy and F1 Score respectively, compared to traditional pruning with fine-tuning approach. Compared to the baseline model, we also achieve a 60.4% decrease in run-time complexity.

Entities:  

Mesh:

Year:  2021        PMID: 34891672     DOI: 10.1109/EMBC46164.2021.9630588

Source DB:  PubMed          Journal:  Annu Int Conf IEEE Eng Med Biol Soc        ISSN: 2375-7477


  1 in total

1.  Beat-Level Interpretation of Intra-Patient Paradigm Based on Object Detection.

Authors:  Man Kang; Xue-Feng Wang; Jing Xiao; He Tian; Tian-Ling Ren
Journal:  Front Cardiovasc Med       Date:  2022-03-18
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.