Literature DB >> 34890941

Sensitive detection of hepatitis C virus using a catalytic hairpin assembly coupled with a lateral flow immunoassay test strip.

Feiya Su1, Mingyuan Zou1, Huina Wu1, Feng Xiao1, Yan Sun1, Chen Zhang2, Wei Gao2, Fengfeng Zhao3, Xiaobo Fan4, Xuejiao Yan5, Guoqiu Wu6.   

Abstract

Currently, PCR is the gold standard for the detection of hepatitis C virus (HCV). However, the PCR technique is complicated and time-consuming, which prevents its application and, clinical point-of-care testing (POCT). Herein, we report a POCT method with simplicity, high sensitivity and specificity, which consists of a catalytic hairpin assembly (CHA) signal amplification system coupled with a lateral flow immunochromatographic (LFIA) test strip for the detection of HCV. Two ingeniously designed hairpin probes were hybridized to form the H1-H2 duplex in the presence of the target DNA. The catalytic hairpin assembly which was characterized of isothermal and enzyme-free, was accomplished within 40 min and the reaction was then applied to a LFIA test strip. Only the H1-H2 duplex labeled with both digoxin and biotin could be captured by the test strip, and the fluorescence value was determined. In addition, we evaluated the application potential for the detection of clinical samples. The reported method demonstrated high sensitivity with a detectable minimum concentration at 1 fM and showed a good linear range from 10 nM to 10pM, and high specificity for various mismatched sequences. The results demonstrated that clinically positive samples could be successfully detected. In conclusion, the reported method is simple, rapid, and free of large-scale equipment. POCT is expected to be useful for HCV detection in clinic.
Copyright © 2021 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Catalytic hairpin assembly; Hepatitis C virus; Lateral flow immunoassay test strip; POCT

Mesh:

Year:  2021        PMID: 34890941     DOI: 10.1016/j.talanta.2021.123122

Source DB:  PubMed          Journal:  Talanta        ISSN: 0039-9140            Impact factor:   6.057


  1 in total

1.  Detection of Ureaplasma urealyticum by Catalytic Hairpin Assembly Combined with a Lateral Flow Immunoassay Strip.

Authors:  Feng Xiao; Qingrong Qu; Mingyuan Zou; Feiya Su; Huina Wu; Yan Sun; Meiling Zhou; Fengfeng Zhao; Yuming Yao; Gulinaizhaer Abudushalamu; Yaya Chen; Chen Zhang; Xiaobo Fan; Guoqiu Wu
Journal:  ACS Omega       Date:  2022-09-15
  1 in total