Literature DB >> 3489016

PET measurement of regional lung density: 1.

D P Schuster, G F Marklin, M A Mintun, M M Ter-Pogossian.   

Abstract

Regional lung density (LD) and lung water (LW) measurements were made with positron transmission and emission tomography (PET) in normal and edematous lung in supine dogs in vivo. A comparison was also made of LD measurements by PET and X-ray CT (used by others to noninvasively assess pulmonary edema). Mean LW was 0.25 +/- 0.06 ml water/ml lung and the mean LD (PET) was 0.32 +/- 0.06 g/ml lung (average ratio of LW to LD was 0.795 +/- 0.041). The LD measurements ranged from 0.25 +/- 0.06 in anterior portions of lung to 0.43 +/- 0.11 g/ml in posterior areas, but the ratio of LW to LD was similar throughout the lung. The LW and LD measurements obtained in both normal and edematous portions of lung were strongly correlated (r = 0.886). Values for LD by PET were consistently higher than values obtained for LD by X-ray CT. These differences are probably due to beam-hardening effects with CT and partial-volume averaging and scattered radiation effects with PET. Nevertheless, PET-LD measurements may be a satisfactory method for following acute changes in LW or for normalizing other PET-derived data.

Entities:  

Mesh:

Year:  1986        PMID: 3489016     DOI: 10.1097/00004728-198609000-00002

Source DB:  PubMed          Journal:  J Comput Assist Tomogr        ISSN: 0363-8715            Impact factor:   1.826


  5 in total

1.  Regional 2-[18F]fluoro-2-deoxy-D-glucose uptake varies in normal lung.

Authors:  T Miyauchi; R L Wahl
Journal:  Eur J Nucl Med       Date:  1996-05

2.  Alveolar recruitment assessed by positron emission tomography during experimental acute lung injury.

Authors:  Jean-Christophe Richard; Didier Le Bars; Nicolas Costes; Fabienne Bregeon; Christian Tourvieille; Franck Lavenne; Marc Janier; Gérard Gimenez; Claude Guerin
Journal:  Intensive Care Med       Date:  2006-09-19       Impact factor: 17.440

3.  Quantitative MRI measurement of lung density must account for the change in T(2) (*) with lung inflation.

Authors:  Rebecca J Theilmann; Tatsuya J Arai; Ahsan Samiee; David J Dubowitz; Susan R Hopkins; Richard B Buxton; G Kim Prisk
Journal:  J Magn Reson Imaging       Date:  2009-09       Impact factor: 4.813

4.  The measurement of lung water.

Authors: 
Journal:  Crit Care       Date:  1999       Impact factor: 9.097

5.  Quantitative pulmonary blood flow measurement using 15O-H2O PET with and without tissue fraction correction: a comparison study.

Authors:  Keiko Matsunaga; Masahiro Yanagawa; Tomoyuki Otsuka; Haruhiko Hirata; Takashi Kijima; Atsushi Kumanogoh; Noriyuki Tomiyama; Eku Shimosegawa; Jun Hatazawa
Journal:  EJNMMI Res       Date:  2017-12-22       Impact factor: 3.138

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.