Literature DB >> 3488527

Quantitative SPECT imaging: influence of object size.

L P Clarke, L L Leong, A N Serafini, I B Tyson, M L Silbiger.   

Abstract

In positron emission tomography (PET) the measured radionuclide concentration or recovery coefficient (RC) in the transverse plane has been shown to be dependent on source size. The RC dependence on object size was therefore experimentally measured for gamma camera SPECT system to determine the influence of additional factors such as: (a) geometrical spatial resolution of each collimator type, (b) scattering effects at each photon energy due to surrounding background, (c) influence of choice of reconstruction filter and (d) photon penetration through the collimator septa. Data were acquired for different collimator types using 99Tcm (140 keV) and 131I (364 keV) to partly differentiate between photon scattering and collimator penetration effects. Results obtained demonstrated that thick septa collimators with low penetration fraction (theoretical leakage less than 3%) are required to minimize the measured response dependence on source size and to obtain a relatively unique relationship independent of photon energy and background activity. Measurements of this type are important for quantitative SPECT imaging in radioimmunoimaging or radioimmunotherapy.

Mesh:

Year:  1986        PMID: 3488527     DOI: 10.1097/00006231-198605000-00006

Source DB:  PubMed          Journal:  Nucl Med Commun        ISSN: 0143-3636            Impact factor:   1.690


  4 in total

1.  Anatomically derived attenuation coefficients for use in quantitative single photon emission tomography studies of the thorax.

Authors:  N P Rowell; J Glaholm; M A Flower; B Cronin; V R McCready
Journal:  Eur J Nucl Med       Date:  1992

2.  A direct ROI quantification method for inherent PVE correction: accuracy assessment in striatal SPECT measurements.

Authors:  Eleonora Vanzi; Maria Teresa De Cristofaro; Silvia Ramat; Barbara Sotgia; Mario Mascalchi; Andreas Robert Formiconi
Journal:  Eur J Nucl Med Mol Imaging       Date:  2007-03-28       Impact factor: 9.236

3.  Quantitative single-photon emission tomography for tumour blood flow measurement in bronchial carcinoma.

Authors:  N P Rowell; M A Flower; B Cronin; V R McCready
Journal:  Eur J Nucl Med       Date:  1993-07

4.  Technetium-99m HMPAO and SPECT in the assessment of blood flow in human lung tumours.

Authors:  N P Rowell; V R McCready; D Tait; M A Flower; B Cronin; G E Adams; A Horwich
Journal:  Br J Cancer       Date:  1989-01       Impact factor: 7.640

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.