Literature DB >> 34879299

The potential of combined shear wave and strain elastography to reduce unnecessary biopsies in breast cancer diagnostics - An international, multicentre trial.

Michael Golatta1, André Pfob2, Christopher Büsch3, Thomas Bruckner3, Zaher Alwafai4, Corinne Balleyguier5, Dirk-André Clevert6, Volker Duda7, Manuela Goncalo8, Ines Gruber9, Markus Hahn9, Panagiotis Kapetas10, Ralf Ohlinger4, Matthieu Rutten11, Riku Togawa12, Mitsuhiro Tozaki13, Sebastian Wojcinski14, Geraldine Rauch15, Joerg Heil12, Richard G Barr16.   

Abstract

BACKGROUND: Shear wave elastography (SWE) and strain elastography (SE) have shown promising potential in breast cancer diagnostics by evaluating the stiffness of a lesion. Combining these two techniques could further improve the diagnostic performance. We aimed to exploratorily define the cut-offs at which adding combined SWE and SE to B-mode breast ultrasound could help reclassify Breast Imaging Reporting and Data System (BI-RADS) 3-4 lesions to reduce the number of unnecessary breast biopsies.
METHODS: We report the secondary results of a prospective, multicentre, international trial (NCT02638935). The trial enrolled 1288 women with BI-RADS 3 to 4c breast masses on conventional B-mode breast ultrasound. All patients underwent SWE and SE (index test) and histopathologic evaluation (reference standard). Reduction of unnecessary biopsies (biopsies in benign lesions) and missed malignancies after recategorising with SWE and SE were the outcome measures.
RESULTS: On performing histopathologic evaluation, 368 of 1288 breast masses were malignant. Following the routine B-mode breast ultrasound assessment, 53.80% (495 of 920 patients) underwent an unnecessary biopsy. After recategorising BI-RADS 4a lesions (SWE cut-off ≥3.70 m/s, SE cut-off ≥1.0), 34.78% (320 of 920 patients) underwent an unnecessary biopsy corresponding to a 35.35% (320 versus 495) reduction of unnecessary biopsies. Malignancies in the new BI-RADS 3 cohort were missed in 1.96% (12 of 612 patients).
CONCLUSION: Adding combined SWE and SE to routine B-mode breast ultrasound to recategorise BI-RADS 4a patients could help reduce the number of unnecessary biopsies in breast diagnostics by about 35% while keeping the rate of undetected malignancies below the 2% ACR BI-RADS 3 definition.
Copyright © 2021 Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  BI-RADS; Breast ultrasound; Shear wave elastography; Unclear breast lesion

Mesh:

Year:  2021        PMID: 34879299     DOI: 10.1016/j.ejca.2021.11.005

Source DB:  PubMed          Journal:  Eur J Cancer        ISSN: 0959-8049            Impact factor:   9.162


  2 in total

1.  Differential Diagnosis Value of Shear-Wave Elastography for Superficial Enlarged Lymph Nodes.

Authors:  Yanjuan Sun; Wen Wang; Chengrong Mi; Qian Zhang; Kun Zhang
Journal:  Front Oncol       Date:  2022-06-30       Impact factor: 5.738

2.  Contrast-enhanced ultrasound of granular cell tumor in breast: A case report with review of the literature.

Authors:  Huanyu Wang; Duo Feng; Tianhui Zou; Yao Liu; Xiaoqin Wu; Jiawei Zou; Rong Huang
Journal:  Front Oncol       Date:  2022-08-23       Impact factor: 5.738

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.