Literature DB >> 34877250

Comparing bite force in untreated and orthodontically treated non- extraction cases with MBT appliance and self ligation technique using T-scan.

Sakshi Gupta1, Gurkeerat Singh1, Sridhar Kannan1, Raj Kumar Singh1, Varun Goyal1, Nishant Gupta1.   

Abstract

AIM: Aim of this cross sectional study was to compare the bite force and the individual tooth load among three groups of patients: cases finished with the Self ligation appliance (Damon-Q®, 0.022"X0.028" prescription) cases finished with the MBT (McLaughlin, Bennett and Trevisi) appliance system (0.022"X0.028"prescription) and orthodontically untreated cases using T-Scan® 9.0 version. MATERIAL &
METHODS: A sample size of sixty non-extraction cases were divided equally into three groups - Group 1: patients treated with Self-ligation appliance (Damon Q®), Group 2: cases treated with the MBT prescription and Group 3: untreated subjects with Class I canine and molar relationship who were used as the control group. The bite force and distribution of force was measured on the right and left side as well as individual tooth loads were measured using the T-Scan® 9.0 device and inter-and intra-group comparisons made using Paired t-Test, ANOVA and Chi-square test. RESULT: The bite forces were balanced on both the sides in cases treated with Self-ligation and MBT appliance. The Self-ligation finishes were marginally better than the MBT group but the difference was statistically insignificant.
CONCLUSION: Orthodontically treated individuals had a better (or more even) bite force distribution compared to untreated participants.
© 2021 Published by Elsevier B.V. on behalf of Craniofacial Research Foundation.

Entities:  

Keywords:  Bite force; Optimum occlusion; Orthodontics; Scan

Year:  2021        PMID: 34877250      PMCID: PMC8628211          DOI: 10.1016/j.jobcr.2021.11.006

Source DB:  PubMed          Journal:  J Oral Biol Craniofac Res        ISSN: 2212-4268


  10 in total

1.  Jaw bite force measurement device.

Authors:  Dennis Flanagan; Horea Ilies; Brendan O'Brien; Anne McManus; Beau Larrow
Journal:  J Oral Implantol       Date:  2010-09-07       Impact factor: 1.779

2.  Articulating paper mark misconceptions and computerized occlusal analysis technology.

Authors:  Robert B Kerstein
Journal:  Dent Implantol Update       Date:  2008-06

3.  Bite force measurements with hard and soft bite surfaces.

Authors:  C M Serra; A E Manns
Journal:  J Oral Rehabil       Date:  2013-05-22       Impact factor: 3.837

4.  Relative contributions of occlusion, maximum bite force, and chewing cycle kinematics to masticatory performance.

Authors:  Casey R Lepley; Gaylord S Throckmorton; Richard F Ceen; Peter H Buschang
Journal:  Am J Orthod Dentofacial Orthop       Date:  2011-05       Impact factor: 2.650

5.  T-scan dental force analysis for routine dental examination.

Authors:  Mark W Montgomery; Lou Shuman; Amy Morgan
Journal:  Dent Today       Date:  2011-07

6.  Computerized occlusal analysis: a new technology.

Authors:  W L Maness; M Benjamin; R Podoloff; A Bobick; R F Golden
Journal:  Quintessence Int       Date:  1987-04       Impact factor: 1.677

7.  Maximum opening and closing forces exerted by diverse skeletal types.

Authors:  E Yildirim; J P DeVincenzo
Journal:  Angle Orthod       Date:  1971-07       Impact factor: 2.079

8.  Masticatory movements and the resulting force.

Authors:  H F Atkinson; R W Shepherd
Journal:  Arch Oral Biol       Date:  1967-02       Impact factor: 2.633

9.  Clinical significance of isometric bite force versus electrical activity in temporal and masseter muscles.

Authors:  M Bakke; L Michler; K Han; E Möller
Journal:  Scand J Dent Res       Date:  1989-12

10.  Correlation between maximum bite force and facial morphology in children.

Authors:  B Ingervall; C Minder
Journal:  Angle Orthod       Date:  1997       Impact factor: 2.079

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.