Literature DB >> 34872576

Postoperative transverse sternal nonunion with a chest wall defect managed by a tibial locking plate and a Gore-Tex dual mesh membrane: a case report.

Tomaz Malovrh1,2, Tomaz Stupnik3, Boris Podobnik4, Jurij Matija Kalisnik4,5.   

Abstract

BACKGROUND: Transverse sternal nonunion is a rare but disabling complication of chest trauma or a transverse sternotomy. Fixation methods, mainly used to manage the more common longitudinal sternal nonunion, often fail, leaving the surgical treatment of transverse nonunion to be a challenge. CASE
PRESENTATION: We present a case of a highly-disabling, postoperative chest wall defect resulting from transverse sternal nonunion after a transverse thoracosternotomy (clamshell incision) and a concomitant rib resection. Following unsuccessful surgical attempts, the sternal nonunion was fixed with a tibial locking plate and bone grafted, while the post-rib resection chest defect was reconstructed with a Gore-Tex dual mesh membrane. Adequate chest stability was achieved, enabling complete healing of the sternal nonunion and the patient's complete recovery.
CONCLUSION: We believe it is important to address both in the rare case of combined postoperative transverse sternal nonunion and the chest wall defect after rib resection. A good outcome was achieved in our patient by fixing the nonunion with an appropriately sized and shaped locking plate with bone grafting and covering the chest defect with a dual mesh membrane.
© 2021. The Author(s).

Entities:  

Keywords:  Chest wall reconstruction; Clamshell incision; Plate fixation; Sternal nonunion; Transverse thoracosternotomy

Mesh:

Substances:

Year:  2021        PMID: 34872576      PMCID: PMC8647373          DOI: 10.1186/s13019-021-01730-5

Source DB:  PubMed          Journal:  J Cardiothorac Surg        ISSN: 1749-8090            Impact factor:   1.637


Background

Sternal nonunion is a rare, potentially disabling complication, which occurs after a sternotomy or a sternal fracture [1]. The vast majority of sternal nonunions are longitudinal and result from healing disturbances after a median sternotomy. Transverse sternal nonunion is far less common, occurring predominantly after a sternal fracture or after a transverse sternotomy, a procedure which is rarely performed [1, 2]. The condition is defined by the lack of radiographic signs showing osseous healing of the sternum, accompanied by localized pain and tenderness for at least 3 months [3]. Persistent fracture line—with or without callus formation or even bone resorption and a gap across the sternum—is usually visible on lateral X-ray radiograph. Computed Tomography (CT) scan can be used to confirm the absence of osseous union between the fragments, especially when the radiographs are inconclusive [4]. Surgical treatment should be considered when the patient with a sternal nonunion is symptomatic [5-7]. However, it is important to note that surgical methods developed and successfully used to manage the more common longitudinal sternal nonunion are generally not applicable to the transverse nonunion [1, 2].

Case presentation

A 50-year-old man was primarily operated on for extensive type B aortic dissection with acute bowel ischemia. The portion of the descending aorta from the origin of the left subclavian artery to just below the superior mesenteric artery was replaced by a tubular graft through an extended posterolateral thoracotomy. The patient recovered well; however, 10 years later, he was diagnosed with an aortic arch aneurysm and severe dilatation of the proximal descending aorta at the site of the anastomosis with descending tubular graft. Transverse thoracosternotomy (clamshell incision) was used to approach and replace the ascending aorta, the aortic arch, and the proximal part of the previous tubular graft in a single session as a re-do procedure. To facilitate the performance of the distal graft to graft anastomosis, the third and part of the fourth ribs on the left side were resected in addition to the transverse sternotomy. The sternotomy was closed with tension wires. Dehiscence of the transverse sternotomy developed during the early postoperative period. Two attempts of tension re-wiring followed by fixation with one-third tubular plate and conventional screws were performed to address the dehiscence, which all failed in a few weeks (Fig. 1a).
Fig. 1

a A failed fixation of the transverse sternal nonunion with one-third tubular plate and tension wiring. b 3D reconstruction of the CT showing a big chest wall defect resulting from sternal nonunion and rib resection. c Intraoperative view of the sternal fixation with a locking tibial plate and closure of the remaining chest wall defects with two Gore-Tex dual mesh membranes

a A failed fixation of the transverse sternal nonunion with one-third tubular plate and tension wiring. b 3D reconstruction of the CT showing a big chest wall defect resulting from sternal nonunion and rib resection. c Intraoperative view of the sternal fixation with a locking tibial plate and closure of the remaining chest wall defects with two Gore-Tex dual mesh membranes Three years after the last unsuccessful revision surgery, the patient returned to our clinic symptomatic with pain and an unstable chest, with his lung herniating through the chest wall defect. Radiographs and a CT scan revealed an extensive chest deformation resulting from a widely displaced sternal nonunion, a bone defect of the sternum resulting from multiple operations, and the resections of the third and fourth ribs on the left side of the chest (Fig. 1b). The patient was operated again by a team of cardiothoracic and orthopaedic trauma surgeons. An extensive adhesiolysis, the removal of the remaining wires, and debridement of the scar tissue were done. The sternal fragments were refreshed until the healthy bone and approximated, while the remaining 1 cm-large defect was filled with a structural iliac crest bone autograft. The fragments were then compressed by bone reduction clamps. The fixation was done using a titanium locking compression plate designed for the distal medial tibia (DepuySynthes, West Chester, Pennsylvania). The plate was intraoperatively shaped to match the markedly changed anatomy of the proximal sternum and fixed using 3.5 mm locking screws. The wider shape of the plate with multiple screw holes provided a good purchase in a smaller portion of the deformed proximal fragment. All the screws were carefully inserted under "finger control" as not to protrude at the back of the sternum. In the meantime, a 2 mm-thick, 20 × 10 cm Gore-Tex dual mesh membrane was attached to the ribs to cover the remaining defect caused by rib resection on the left side. The membrane was attached by using interrupted trans-costal sutures from heavy polypropylene. More than 60 sutures were placed along the two adjacent ribs above and below the defect to achieve the required strength. Another membrane of a 10 × 5 cm size was applied to the remaining soft tissue defect in the second intercostal space on the right side (Fig. 1c). The wound was then closed, the thoracic cavity was drained, and two drains were placed subcutaneously to prevent haematoma or a subsequent seroma formation. The postoperative recovery of the patient was uneventful. The chest X-ray and the CT scan, performed 1 year after the operation showed the complete healing of the sternum and good positions of the membranes (Fig. 2). After 3 years, the chest remained stable with no pain or lung herniation. There were also no implant-related problems and, therefore, no need for plate removal.
Fig. 2

Chest X-ray. a lateral; b AP view. c 3D reconstruction of the CT 1 year postoperatively showing healing of the sternum and good Gore-Tex dual mesh membranes position

Chest X-ray. a lateral; b AP view. c 3D reconstruction of the CT 1 year postoperatively showing healing of the sternum and good Gore-Tex dual mesh membranes position

Discussion and conclusions

Transverse sternal nonunion is a rare but disabling complication that occurrs mainly after a traumatic sternal fracture or a rarely-performed transverse sternotomy [1]. The rate of nonunion is less than 1% after sternal fractures, while the condition becomes more common after a transverse sternotomy, with the rate of 6.8%, and thus represents an important chronic complication [7, 8]. A transverse thoracosternotomy (known as a Clamshell incision) is typically used in double-lung transplantations as it provides excellent access to the heart, lungs, and the great vessels [8, 9]. Due to multidirectional movements with tension and compression forces that act in all planes, fixation of the transverse sternotomy, sternal fracture, or transverse nonunion remains a challenge [1, 2]. There is limited published data on transverse sternal nonunion, especially after a sternotomy, mostly involving case reports or small case series [1, 10, 11]. Different fixation materials and techniques were described to fix transverse fractures, osteotomies, or nonunions, with tension wiring and plating being the most commonly performed [2, 7, 10]. Tension wires, which are still typically used to close a median sternotomy, often fail when used for a transverse sternotomy closure, which also was the case in our patient during the early postoperative period. A sternal notching technique should be considered when a transverse sternotomy is performed. The technique was described as the modification of sternal transection from transverse to inverted V-shaped. It allows for a more precise fit of the sternal fragments at closure, provides better stability, and possibly lowers the transverse sternal nonunion rate [12]. When using cerclage wires, the crossed wiring closure technique reduced the incidence of sternal dehiscence compared to the uncrossed technique [13]. In their comparative study, Qin-Yun Ma and co-workers showed a significantly higher sternal healing rate in the plated group compared to the tension-wired group after a transverse sternotomy [14]. Biomechanical advantages of sternal plating were previously shown in a cadaveric study [15]. Other authors also reported good functional outcomes of sternal plating with a high rate of union, mainly after using one or two parallel locking plates [2, 6, 8, 9, 11, 16, 17]. In contrast to conventional plating, locking implants with screws locked in the plate (angularly stable fixation) better resist continuous multidirectional forces that act on the construct during breathing. Additionally, monocortical locking screws can be a safer option to prevent an iatrogenic injury to the vital retrosternal structures. But on the other hand, they provide less purchase than bicortical locking screws, especially in a weaker bone [6, 11]. A review of the published literature done by Schulz et al. [18] showed good results for the most locking plate systems that were used and a review from Klei et al. from 2018 confirmed that plating was the most common type of fixation after sternal fractures (83%), with a reasonable consolidation and low complication rate [10, 18]. In our case, the patient had a symptomatic postoperative chest wall defect because of transverse sternal nonunion combined with a rib resection. The nonunion was previously unsuccessfully treated with tension wiring and one-third tubular plate fixed with conventional, non-locking screws. Following available published data, we fixed the nonunion with a locking plate. Due to the anatomical conditions, we did not use one or two regular longitudinal 3.5 mm locking plates. Instead, we decided to use a single, stronger locking plate that is typically used to fix distal tibial fractures, which we shaped to the bone. As our patient was tall and obese, the plate appeared to be well sized. The broad ending of the plate with multiple locking screws applied in different directions provided a strong purchase in a deformed proximal fragment. The sternal defect was also bone grafted with a tricortical iliac crest autograft. Bone grafting was advocated for and performed in some other published cases of transverse sternal nonunion with a bone defect [1, 2, 19, 20]. Common late complications of the sternal plating are local pain and irritation caused by the prominent material, requiring removal of the plate in 15.4% and 27% of the patients, respectively [5, 11]. There were no implant-related problems in our case and therefore no need for plate removal. A Gore-Tex dual mesh membrane was additionally used in our patient to cover the chest wall defect after rib resection. Gore-Tex dual mesh membranes were shown to be a good option for reconstructing chest wall defects, especially after wide surgical resections [21-23]. By using the membranes, we successfully closed the remaining defects and treated the lung herniation. Furthermore, we believe that membranes also diminished the load applied on the plate during continuous chest movements and possibly contributed to the prevention of an early plate failure. We reviewed the literature for similar cases and could only find a few small series and case reports describing the successful combination of titanium plates with Gore-Tex dual mesh membranes to achieve a stable chest that allows the complete range of respiratory movements, most of them being used after wide surgical resection of the thorax [22, 24]. However, we could not find any reports of similar treatment in such an extensive postoperatively deformed chest, resulting from widely displaced sternal nonunion and rib resection. To our knowledge, this is also the first reported case of a specific tibial plate successfully being used to fix a transverse sternal nonunion. In conclusion, we presented a rare case of a patient with a symptomatic postoperative chest wall defect resulting from transverse sternal nonunion after a transverse thoracosternotomy (clamshell incision) and concomitant rib resection. We believe that addressing both the transverse sternal nonunion and the chest wall defect after rib resection with a properly sized and shaped locking plate with bone grafting and a dual mesh membrane, respectively, was important for a favourable outcome in our patient.
  22 in total

1.  Treatment of posttraumatic sternal non-union with a locked sternum-osteosynthesis plate (TiFix).

Authors:  Christian Queitsch; Benjamin Kienast; Christine Voigt; Justus Gille; Christian Jürgens; Arndt P Schulz
Journal:  Injury       Date:  2011-01       Impact factor: 2.586

2.  Sternal plating to prevent malunion of transverse sternotomy in lung transplantation.

Authors:  Kimberly L Gandy; Michael J Moulton
Journal:  Ann Thorac Surg       Date:  2008-10       Impact factor: 4.330

3.  Experience of sternal secondary closure by means of a titanium fixation system after transverse thoracosternotomy.

Authors:  Tadashi Motomura; Brian Bruckner; Saverio La Francesca; Sebastian Mittelhaus; Chuma Chike-Obi; Joel Leon-Becerril; Uy Ngo; Matthias Loebe
Journal:  Artif Organs       Date:  2011-07-25       Impact factor: 3.094

4.  The combination of polytetrafluoroethylene mesh and titanium rib implants: an innovative process for reconstructing large full thickness chest wall defects.

Authors:  Jean-Philippe Berthet; Jean-Marie Wihlm; Ludovic Canaud; Frédérique Joyeux; Catalin Cosma; Keira Hireche; Pierre Alric; Charles-Henri Marty-Ané
Journal:  Eur J Cardiothorac Surg       Date:  2012-03-04       Impact factor: 4.191

5.  Non-union of fractures of the sternum.

Authors:  I I Mayba
Journal:  J Bone Joint Surg Am       Date:  1985-09       Impact factor: 5.284

6.  Application of the titanium plate fixation system in sternum transverse incisions.

Authors:  Qin-Yun Ma; Yong-Jun Zhu; Lie-Wen Pang; Gang Chen; Ji Chen; Zhi-Ming Chen
Journal:  Am Surg       Date:  2011-11       Impact factor: 0.688

7.  Osteosynthesis of sternal fractures with double locking compression plate fixation: a retrospective cohort study.

Authors:  Nina Kalberer; Herman Frima; Christian Michelitsch; Jan Kloka; Christoph Sommer
Journal:  Eur J Orthop Surg Traumatol       Date:  2019-08-28

8.  Surgical fixation of sternal fractures: preoperative planning and a safe surgical technique using locked titanium plates and depth limited drilling.

Authors:  Stefan Schulz-Drost; Pascal Oppel; Sina Grupp; Sonja Schmitt; Roman Th Carbon; Andreas Mauerer; Friedrich F Hennig; Thomas Buder
Journal:  J Vis Exp       Date:  2015-01-05       Impact factor: 1.355

9.  Current treatment and outcomes of traumatic sternal fractures-a systematic review.

Authors:  Dorine S Klei; Mirjam B de Jong; F Cumhur Öner; Luke P H Leenen; Karlijn J P van Wessem
Journal:  Int Orthop       Date:  2018-04-26       Impact factor: 3.075

10.  Sternal nonunion.

Authors:  David A Coons; J David Pitcher; Maceo Braxton; Barry T Bickley
Journal:  Orthopedics       Date:  2002-01       Impact factor: 1.390

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.