| Literature DB >> 34870803 |
Rajvi Mehta1, Shizuka Tomatzu2, Dingcai Cao2, Alexander Pleet1, Alexander Mokhur2, Ahmad A Aref1, Thasarat Sutabutr Vajaranant3.
Abstract
INTRODUCTION: To evaluate the refractive outcome of combined cataract extraction and glaucoma drainage device (GDD) surgery.Entities:
Keywords: Cataract; Combined surgery; Glaucoma implant; Refractive outcome
Year: 2021 PMID: 34870803 PMCID: PMC8770753 DOI: 10.1007/s40123-021-00434-2
Source DB: PubMed Journal: Ophthalmol Ther
Fig. 1The Baerveldt GDD is a non-valved GDD while the Ahmed GDD is a valved GDD. Image
source: https://www.willseye.org/glaucoma-tube-shunts/
Patient preoperative and operative clinical information for (A) included eyes and (B) excluded eyes
(A) Number of eyes (patients) Preoperative BCVA (best corrected visual acuity) 20/20–20/40 20/50–20/200 | 42 (38) Number (%) 10 (24%) 32 (76%) |
| Glaucoma type (open angle) | 42 (100%) |
| Selected lens type | |
| Monofocal 1-piece SN60 | 42 (100%) |
| Location of lens | |
| Capsular bag | 42 (100%) |
| Glaucoma surgery drainage device type | |
Ahmed valve shunt Baerveldt glaucoma implant | 7 (17%) 35 (83%) |
| Preoperative axial length (mean ± SD) | 23.89 ± 1.26 |
| Preoperative anterior chamber depth (mean ± SD) | 2.96 ± 0.50 |
Refractive outcomes at 3–6 months postoperatively
| Total number of eyes | 42 |
| Difference in spherical equivalent between target and final refractive outcome after surgery | |
Outside ± 1.00D Between + 1.00D and − 1.00D | 12 (29%) 30 (71%) |
| Axial length of eyes with postoperative spherical equivalent | |
Outside ± 1.00D (mean ± SD) Between + 1.00D and − 1.00D (mean ± SD) | 25.37 ± 0.98 23.34 ± 0.89 |
Number of eyes with postoperative induced cylinder Amount of induced cylinder (mean ± SD) | 12 (29%) 0.52 ± 0.49 |
Fig. 2Regression analysis showing relation between difference in refractive outcome [spherical equivalent (SE) in diopters (D)] and preoperative intraocular pressure (IOP0); postoperative IOP at 1 month (IOP1), 3 months (IOP3), 6 months (IOP6), and 12 months (IOP12) after surgery; and preoperative axial length. Red data points = 30 eyes with final refractive outcome at goal (± 1.00D of the target refraction). Green data points = 12 eyes with final refractive outcome outside goal (> ± 1.00D of the target refraction)
| Refractive rehabilitation in patients undergoing combined cataract and glaucoma surgery depends on multiple pre- and postoperative factors. |
| This is the largest study which aimed to evaluate refractive outcomes after combined cataract extraction with glaucoma drainage device implantation. |
| Favorable refractive outcomes within 1.00D of the target refraction were noted in most patients. |
| Longer preoperative axial length (AL) was noted to be a risk factor in patients with refractive outcomes > 1.00D from target refraction, and this knowledge can help guide patient education, intraocular lens (IOL) selection, and the consent process in the preoperative period. |