Literature DB >> 34860426

Influence of Digital Technologies and Framework Design on the Load to Fracture of Co-Cr Posterior Fixed Partial Denture Frameworks.

Celia Tobar1, Veronica Rodriguez1, Carlos Lopez-Suarez1, Jesus Pelaez1, Maria J Suarez1.   

Abstract

PURPOSE: To compare the load to fracture of cobalt-chromium (Co-Cr) 3-unit posterior fixed partial denture (FPD) frameworks manufactured by conventional and digital techniques and to evaluate the influence of the framework design on the fracture load.
MATERIAL AND METHODS: Eighty 3-unit Co-Cr posterior FPD frameworks were fabricated with two designs: intermediate pontic (n = 40) and cantilever (n = 40). Each design was randomly divided into four groups (n = 10): casting, direct metal laser sintering, soft metal milling, and hard metal milling. After thermal cycling, all specimens were subjected to a 3-point bending test until fracture. Data were statistically analyzed using one-way ANOVA, Welch and Brown-Forsythe test, Ryan-Einot-Gabriel-Welsch F and Tamhane T2 post hoc test, Student's t test, and Weibull statistics (α = 0.05).
RESULTS: Significant differences (p < 0.001; F = 39.59) were found among intermediate pontic frameworks (except between laser sintering and hard metal milling), and cantilevered frameworks (F = 36.75) (except between laser sintering and hard metal milling, and casting and soft metal milling). The cantilever groups showed load to fracture values significantly lower than those of the intermediate pontic (p < 0.001; F = 28.29). The Weibull statistics corroborated the results.
CONCLUSIONS: Hard metal milling and laser sintered frameworks exhibited the highest load to fracture values. However, all tested frameworks demonstrated clinically acceptable load to fracture values. The framework design directly affected the fracture load, with drastically lower values in cantilevered frameworks.
© 2021 by the American College of Prosthodontists.

Entities:  

Keywords:  CAD-CAM technologies; base metal alloys; cantilever; fixed prostheses; fracture

Mesh:

Substances:

Year:  2021        PMID: 34860426     DOI: 10.1111/jopr.13458

Source DB:  PubMed          Journal:  J Prosthodont        ISSN: 1059-941X            Impact factor:   3.485


  2 in total

1.  Strength Tests of Alloys for Fixed Structures in Dental Prosthetics.

Authors:  Łukasz Bojko; Anna M Ryniewicz; Wojciech Ryniewicz
Journal:  Materials (Basel)       Date:  2022-05-13       Impact factor: 3.748

2.  Impact of the Veneering Technique and Framework Material on the Failure Loads of All-Ceramic Computer-Aided Design/Computer-Aided Manufacturing Fixed Partial Dentures.

Authors:  Sebastian Hinz; Tobias Bensel; Wolfgang Bömicke; Anders Henningsen; Judith Rudolph; Arne F Boeckler
Journal:  Materials (Basel)       Date:  2022-01-19       Impact factor: 3.623

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.