Literature DB >> 3485039

Some considerations on experimental lens implant in the rabbit eye, a SEM-study.

M J Figueras, W L Jongebloed, J G Worst.   

Abstract

Intraocular implantation of an iris-bridge or lobster-claw lens was performed on a rabbit eye. The incisions were closed with stainless steel-vanadium sutures. Two months after implantation loosening at one side of the connection between lens and iris was noted, which resulted in long-term intermittent touch of the corneal endothelium. The reaction of the endothelium to the corneal sutures and the contact area of artificial lens and corneal endothelium were studied by SEM.

Entities:  

Mesh:

Year:  1986        PMID: 3485039     DOI: 10.1007/BF00142363

Source DB:  PubMed          Journal:  Doc Ophthalmol        ISSN: 0012-4486            Impact factor:   2.379


  7 in total

1.  The human corneal endothelium.

Authors:  H E Kaufman; J A Capella; J E Robbins
Journal:  Am J Ophthalmol       Date:  1966-05       Impact factor: 5.258

2.  Endothelial damage associated with intraocular lenses.

Authors:  W M Bourne; H E Kaufman
Journal:  Am J Ophthalmol       Date:  1976-04       Impact factor: 5.258

3.  The effect of intraocular lens implantation on the corneal endothelium.

Authors:  S L Forstot; W L Blackwell; N S Jaffe; H E Kaufman
Journal:  Trans Sect Ophthalmol Am Acad Ophthalmol Otolaryngol       Date:  1977 Mar-Apr

4.  Regenerative capacity of the corneal endothelium in rabbit and cat.

Authors:  D L Van Horn; D D Sendele; S Seideman; P J Buco
Journal:  Invest Ophthalmol Vis Sci       Date:  1977-07       Impact factor: 4.799

5.  Foreign body giant cells selectively covering haptics of intraocular lens implants: indicators of poor toleration?

Authors:  J R Wolter
Journal:  Ophthalmic Surg       Date:  1983-10

6.  Foreign body giant cells on intraocular lens implants.

Authors:  J R Wolter
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  1982       Impact factor: 3.117

7.  Effects of ultrasound on the corneal endothelium: II. The endothelial repair process.

Authors:  L E Olson; J Marshall; N S Rice; R Andrews
Journal:  Br J Ophthalmol       Date:  1978-03       Impact factor: 4.638

  7 in total
  3 in total

1.  Stainless steel as suturing material in human- and rabbit corneas: a SEM-study.

Authors:  W L Jongebloed; W J Rijneveld; P L Cuperus; P van Andel; J G Worst
Journal:  Doc Ophthalmol       Date:  1988 Oct-Nov       Impact factor: 2.379

2.  A SEM-study of a keratoconus and an artificially aged human cornea.

Authors:  W L Jongebloed; D Humalda; P van Andel; J F Worst
Journal:  Doc Ophthalmol       Date:  1986-12-30       Impact factor: 2.379

3.  Descriptive anatomy of the ageing process of the human cornea as visualized by SEM.

Authors:  W L Jongebloed; F Dijk; J F Worst
Journal:  Doc Ophthalmol       Date:  1987 Sep-Oct       Impact factor: 2.379

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.