Literature DB >> 34849668

The influence of the 2020 COVID-19 pandemic on the implantation rates of cardiac implantable electronic devices in Germany: changes between 2020 Q1-Q3 and 2019 Q1-Q3.

Jörg Otto Schwab1, Jan Wiese2, Tino Hauser2.   

Abstract

AIMS: During the early phase of the COVID-19 pandemic, hospital admissions for several medical and surgical conditions declined. Few data are available with respect to elective cardiac implantable electronic device (CIED) implantation. The aim of the present study was to determine the impact of the COVID-19 pandemic on the monthly CIED implantation rates in Germany (January-September 2020 vs. 2019). METHODS AND
RESULTS: The monthly rates of CIED implantation for the 2019 pre- and 2020 pandemic periods were retrieved from the Institute für das Entgeltsystem im Krankenhaus using German Operation and Procedure Classification codes to identify pacemakers (PMs), implantable cardioverter/defibrillators (ICDs), and cardiac resynchronization therapy (CRT) systems. Compared with 2019, the COVID-19 pandemic was associated with an overall decline of CIED implantation rates of -2.6%, reaching -22.9% in April 2020. Stratified by device type, the patterns of implantation were similar between PMs and ICDs, with maximal declines of -24.3% and -23.2% in April, respectively. Thereafter, the implantation rates gradually increased before stabilizing to rates similar to those observed in 2019. CRT implantation rates also declined in the early pandemic wave, but the overall 2020 rates increased by +4.3% likely driven by an increase of +16.5% (June-September). All the observed percentage differences of monthly device type related implantation rates demonstrated a statistical significance.
CONCLUSION: The COVID-19 pandemic had a significant impact on the implantation of CIEDs in Germany. A differential pattern of resource utilization was observed with a catch-up effect for PMs and ICDs. The implantation rates of CRT systems also declined, but they increased rapidly and remained higher than those of 2019.
© The Author(s) 2021. Published by Oxford University Press on behalf of the European Society of Cardiology.

Entities:  

Keywords:  Cardiac implantable electronic device • COVID-19 • Cardiac resynchronization therapy • Implantable cardioverter/defibrillator • implantation rate • Pacemaker

Mesh:

Year:  2022        PMID: 34849668      PMCID: PMC8690261          DOI: 10.1093/ehjqcco/qcab091

Source DB:  PubMed          Journal:  Eur Heart J Qual Care Clin Outcomes        ISSN: 2058-1742


  2 in total

1.  Full-duplex enabled wireless power transfer system via textile for miniaturized IMD.

Authors:  Jaeho Lee; Beomjun Bae; Beomjin Kim; Byunghun Lee
Journal:  Biomed Eng Lett       Date:  2022-07-17

Review 2.  Cardiovascular disease and COVID-19, a deadly combination: A review about direct and indirect impact of a pandemic.

Authors:  Rafael Vidal-Perez; Mariana Brandão; Michal Pazdernik; Karl-Patrik Kresoja; Myriam Carpenito; Shingo Maeda; Rubén Casado-Arroyo; Saverio Muscoli; Janine Pöss; Ricardo Fontes-Carvalho; Jose Manuel Vazquez-Rodriguez
Journal:  World J Clin Cases       Date:  2022-09-26       Impact factor: 1.534

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.