| Literature DB >> 3484833 |
T G Brott, M J Gelfand, C C Williams, J A Spilker, V S Hertzberg.
Abstract
Single photon emission computed tomography (SPECT) was performed in 31 patients with cerebral infarction and 13 who had had transient ischemic attacks, using iodine-123-labeled N,N,N'-trimethyl-N'-(2-hydroxyl-3-methyl-5-iodobenzyl)-1,3-propanediamin e (I-123-HIPDM) as the radiopharmaceutical. SPECT scans were compared with computed tomographic (CT) scans. SPECT was as sensitive as CT in detecting cerebral infarction (94% vs. 84%). The abnormalities were larger on the SPECT scans than on the CT scans in 19 cases, equal in seven, and smaller in five (SPECT abnormalities greater than or equal to CT abnormalities in 86% of cases). Fifteen of 30 patients with hemispheric infarction had decreased perfusion (decreased uptake of I-123-HIPDM) to the cerebellar hemisphere contralateral to the cerebral hemisphere involved by the infarction (crossed cerebellar diaschisis). Nine of these 15 patients had major motor deficits, while only one of the 15 without crossed cerebellar diaschisis had a major motor deficit.Entities:
Mesh:
Substances:
Year: 1986 PMID: 3484833 DOI: 10.1148/radiology.158.3.3484833
Source DB: PubMed Journal: Radiology ISSN: 0033-8419 Impact factor: 11.105