Literature DB >> 34843040

Impact of sigmoid septum on periprocedural outcomes following transcatheter aortic valve implantation using current-generation valves.

Masaki Tsuda1, Yasuyuki Egami1, Yutaka Matsuhiro1, Hitoshi Nakamura1, Koji Yasumoto1, Naotaka Okamoto1, Yasuharu Matsunaga-Lee1, Masamichi Yano1, Masami Nishino2, Jun Tanouchi1.   

Abstract

The role of sigmoid septum (SS) observed using preprocedural transthoracic echocardiography (TTE) in patients undergoing transcatheter aortic valve implantation (TAVI) remains unknown. This study aimed to compare clinical outcomes of TAVI using the current-generation transcatheter heart valves in patients with and without SS. We divided 140 consecutive patients, excluding four patients who underwent pacemaker implantation before TAVI, into two groups (those with and without SS) and compared the periprocedural outcomes, including new pacemaker implantation, within 30 days post-TAVI. Thirty-five patients (25%; 32 female patients) had SS before TAVI. The body surface area and aortic annulus area measured using computed tomography were significantly smaller in patients with SS than in those without SS (1.40 m2 vs. 1.48 m2, P = 0.03; and 372 mm2 vs. 409 mm2, P < 0.01; respectively). Device success was achieved in all patients with SS. Postprocedural TTE on 30 days post-TAVI showed no significant differences in the valvular hemodynamics between patients with and without SS. No severe prosthesis-patient mismatch was noted on TTE, although the transcatheter heart valve size tended to be smaller in patients with SS. Within 30 days of the TAVI, three (8.6%) and eight (7.6%) patients with and without SS, respectively, had new pacemaker implantation (P = 0.86). The presence of SS was not associated with periprocedural outcomes following TAVI in patients without pre-existing pacemakers. No specific assessment or treatment strategy is required for the TAVI in patients with SS using the current-generation devices.
© 2021. The Author(s), under exclusive licence to Springer Nature B.V.

Entities:  

Keywords:  Conduction disturbance; Echocardiography; Pacemaker implantation; Sigmoid septum; Transcatheter aortic valve implantation

Mesh:

Year:  2021        PMID: 34843040     DOI: 10.1007/s10554-021-02479-7

Source DB:  PubMed          Journal:  Int J Cardiovasc Imaging        ISSN: 1569-5794            Impact factor:   2.357


  27 in total

1.  Recommendations for cardiac chamber quantification by echocardiography in adults: an update from the American Society of Echocardiography and the European Association of Cardiovascular Imaging.

Authors:  Roberto M Lang; Luigi P Badano; Victor Mor-Avi; Jonathan Afilalo; Anderson Armstrong; Laura Ernande; Frank A Flachskampf; Elyse Foster; Steven A Goldstein; Tatiana Kuznetsova; Patrizio Lancellotti; Denisa Muraru; Michael H Picard; Ernst R Rietzschel; Lawrence Rudski; Kirk T Spencer; Wendy Tsang; Jens-Uwe Voigt
Journal:  J Am Soc Echocardiogr       Date:  2015-01       Impact factor: 5.251

2.  A Highly Predictive Risk Model for Pacemaker Implantation After TAVR.

Authors:  Yoshio Maeno; Yigal Abramowitz; Hiroyuki Kawamori; Yoshio Kazuno; Shunsuke Kubo; Nobuyuki Takahashi; Geeteshwar Mangat; Kazuaki Okuyama; Mohammad Kashif; Tarun Chakravarty; Mamoo Nakamura; Wen Cheng; John Friedman; Daniel Berman; Raj R Makkar; Hasan Jilaihawi
Journal:  JACC Cardiovasc Imaging       Date:  2017-04-12

3.  Transcatheter Aortic-Valve Replacement with a Self-Expanding Valve in Low-Risk Patients.

Authors:  Jeffrey J Popma; G Michael Deeb; Steven J Yakubov; Mubashir Mumtaz; Hemal Gada; Daniel O'Hair; Tanvir Bajwa; John C Heiser; William Merhi; Neal S Kleiman; Judah Askew; Paul Sorajja; Joshua Rovin; Stanley J Chetcuti; David H Adams; Paul S Teirstein; George L Zorn; John K Forrest; Didier Tchétché; Jon Resar; Antony Walton; Nicolo Piazza; Basel Ramlawi; Newell Robinson; George Petrossian; Thomas G Gleason; Jae K Oh; Michael J Boulware; Hongyan Qiao; Andrew S Mugglin; Michael J Reardon
Journal:  N Engl J Med       Date:  2019-03-16       Impact factor: 91.245

4.  Transcatheter Aortic-Valve Replacement with a Balloon-Expandable Valve in Low-Risk Patients.

Authors:  Michael J Mack; Martin B Leon; Vinod H Thourani; Raj Makkar; Susheel K Kodali; Mark Russo; Samir R Kapadia; S Chris Malaisrie; David J Cohen; Philippe Pibarot; Jonathon Leipsic; Rebecca T Hahn; Philipp Blanke; Mathew R Williams; James M McCabe; David L Brown; Vasilis Babaliaros; Scott Goldman; Wilson Y Szeto; Philippe Genereux; Ashish Pershad; Stuart J Pocock; Maria C Alu; John G Webb; Craig R Smith
Journal:  N Engl J Med       Date:  2019-03-16       Impact factor: 91.245

5.  Sigmoid Septum and Balloon-Expandable Transcatheter Aortic Valve Replacement: A Cautionary Tale.

Authors:  Andreas R de Biasi; Berhane Worku; Nikolaos J Skubas; Arash Salemi
Journal:  J Heart Valve Dis       Date:  2015-07

6.  Asymmetric septal hypertrophy in patients with severe aortic stenosis: the usefulness of associated septal myectomy.

Authors:  Luigi Di Tommaso; Paolo Stassano; Vito Mannacio; Veronica Russolillo; Mario Monaco; Giovanni Pinna; Carlo Vosa
Journal:  J Thorac Cardiovasc Surg       Date:  2012-02-15       Impact factor: 5.209

7.  Minimizing Permanent Pacemaker Following Repositionable Self-Expanding Transcatheter Aortic Valve Replacement.

Authors:  Hasan Jilaihawi; Zhengang Zhao; Run Du; Cezar Staniloae; Muhamed Saric; Peter J Neuburger; Michael Querijero; Alan Vainrib; Kazuhiro Hisamoto; Homam Ibrahim; Tara Collins; Emily Clark; Illya Pushkar; Daniel Bamira; Ricardo Benenstein; Afnan Tariq; Mathew Williams
Journal:  JACC Cardiovasc Interv       Date:  2019-08-28       Impact factor: 11.195

8.  Prevalence, clinical correlates, and prognosis of discrete upper septal thickening on echocardiography: the Framingham Heart Study.

Authors:  Tulio Diaz; Michael J Pencina; Emelia J Benjamin; Jayashri Aragam; Deborah L Fuller; Karol M Pencina; Daniel Levy; Ramachandran S Vasan
Journal:  Echocardiography       Date:  2008-10-23       Impact factor: 1.724

9.  Transcatheter Aortic Valve Replacement for Severe Aortic Stenosis Complicated by Sigmoid Septum.

Authors:  Kizuku Yamashita; Tomoyuki Fujita; Satsuki Fukushima; Yusuke Shimahara; Yuta Kume; Yorihiko Matsumoto; Naonori Kawamoto; Kimito Minami; Daijiro Kabata; Hideaki Kanzaki; Chisato Izumi; Toshihisa Anzai; Junjiro Kobayashi
Journal:  Circ J       Date:  2018-10-05       Impact factor: 2.993

10.  Valve Academic Research Consortium 3: updated endpoint definitions for aortic valve clinical research.

Authors:  Philippe Généreux; Nicolo Piazza; Maria C Alu; Tamim Nazif; Rebecca T Hahn; Philippe Pibarot; Jeroen J Bax; Jonathon A Leipsic; Philipp Blanke; Eugene H Blackstone; Matthew T Finn; Samir Kapadia; Axel Linke; Michael J Mack; Raj Makkar; Roxana Mehran; Jeffrey J Popma; Michael Reardon; Josep Rodes-Cabau; Nicolas M Van Mieghem; John G Webb; David J Cohen; Martin B Leon
Journal:  Eur Heart J       Date:  2021-05-14       Impact factor: 29.983

View more
  1 in total

1.  Evaluation of ımpact of sigmoid septum on periprocedural outcomes following transcatheter aortic valve ımplantation.

Authors:  Mustafa Dogdus
Journal:  Int J Cardiovasc Imaging       Date:  2021-12-21       Impact factor: 2.357

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.