Literature DB >> 34838429

Pipeline flex embolization device for the treatment of large unruptured posterior circulation aneurysms: Single-center experience.

Li Li1, Bu-Lang Gao1, Qiao-Wei Wu1, Qiu-Ji Shao1, Zi-Liang Wang1, Kun Zhang1, Tian-Xiao Li2.   

Abstract

PURPOSE: To investigate the safety and effect of the Pipeline Embolization Device (PED) Flex device in the treatment of large unruptured posterior circulation aneurysms in a single center.
MATERIALS AND METHODS: Patients with large unruptured posterior circulation aneurysms which were treated with the PED Flex device were enrolled. The clinical, endovascular and follow-up data were analyzed, and the O'Kelly-Marotta (OKM) grading system was used to assess the aneurysm occlusion status.
RESULTS: Fourteen patients with 14 large posterior circulation aneurysms who were treated with the PED Flex device were enrolled. The maximal diameter of aneurysm was 17.0 ± 3.9 mm. Fourteen PED Flex devices were deployed in 14 patients, with a technical success rate of 100%. All stents covered the aneurysm neck with good wall adherence and patent parent artery. Ten (71.4%) aneurysms were treated with a single PED Flex device each, and four (28.6%) patients experienced additional coiling. No neurological complications occurred in the periprocedural period. The mRS was 0 in eleven (78.6%) patients, 1 in two (14.3%), and 2 in one (7.1%) at discharge. All patients were followed up at 6-28 months (median 18), with an mRS score of 0 in all patients. Twelve (85.7%) patients experienced digital subtraction angiography 6-28 (median 18) months after the embolization procedure, and the OKM grade was D in nine (75%), C in two (16.7%), and B in one (8.3%).
CONCLUSION: The Pipeline Flex Embolization Device can be safely applied to treat large unruptured posterior circulation aneurysms with a high complete aneurysm occlusion rate at follow-up.
Copyright © 2021 Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  Complications; Effect; Large unruptured aneurysms; Pipeline flex embolization device; Posterior circulation

Mesh:

Year:  2021        PMID: 34838429     DOI: 10.1016/j.jocn.2021.11.006

Source DB:  PubMed          Journal:  J Clin Neurosci        ISSN: 0967-5868            Impact factor:   1.961


  3 in total

1.  Flow Diversion vs. Stent-Assisted Coiling in the Treatment of Intradural Large Vertebrobasilar Artery Aneurysms.

Authors:  Qiaowei Wu; Chunxu Li; Shancai Xu; Chunlei Wang; Zhiyong Ji; Jingtao Qi; Yuchen Li; Bowen Sun; Huaizhang Shi; Pei Wu
Journal:  Front Neurol       Date:  2022-06-10       Impact factor: 4.086

Review 2.  Shape Memory Polymer-Based Endovascular Devices: Design Criteria and Future Perspective.

Authors:  Sergio A Pineda-Castillo; Aryn M Stiles; Bradley N Bohnstedt; Hyowon Lee; Yingtao Liu; Chung-Hao Lee
Journal:  Polymers (Basel)       Date:  2022-06-21       Impact factor: 4.967

3.  Risk factors for repeated recurrence of cerebral aneurysms treated with endovascular embolization.

Authors:  Yong-Feng Han; Peng Jiang; Zhong-Bin Tian; Xi-Heng Chen; Jian Liu; Zhong-Xue Wu; Bu-Lang Gao; Chun-Feng Ren
Journal:  Front Neurol       Date:  2022-09-29       Impact factor: 4.086

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.