Literature DB >> 34837215

A Wireless Fully-Passive Acquisition of Biopotentials.

Shiyi Liu1, Xueling Meng2, Jianwei Zhang2, Junseok Chae2.   

Abstract

Biopotential signals contain essential information for assessing the functionality of organs and diagnosing diseases. We present a flexible sensor, capable of measuring biopotentials, in real time, in a wireless and fully-passive manner. The flexible sensor collects and transmits biopotentials to an external reader without wire, battery, or harvesting/regulating element. The sensor is fabricated on a 90 μm-thick polyimide substrate with a footprint of 18 × 15 × 0.5 mm3. The wireless fully-passive acquisition of biopotentials is enabled by the RF (Radio Frequency) microwave backscattering effect where the biopotentials are modulated by an array of varactors with incoming RF carrier that is backscattered to the external reader. The flexile sensor is verified and validated by emulated signal and electrocardiogram (ECG), electromyogram (EMG), and electrooculogram (EOG), respectively. A deep learning algorithm analyzes the signal quality of wirelessly acquired data, along with the data from commercially available wired sensor counterparts. Wired and wireless data shows <3% discrepancy in deep learning testing accuracy for ECG and EMG up to the wireless distance of 240 mm. Wireless acquisition of EOG further demonstrates accurate tracking of horizontal eye movement with deep learning training and testing accuracy reaching up to 93.6% and 92.2%, respectively, indicating successful detection of biopotentials signal as low as 250 μVPP. These findings support that the real-time wireless fully-passive acquisition of on-body biopotentials is indeed feasible and may find various uses for future clinical research.
© 2022. Springer Science+Business Media, LLC, part of Springer Nature.

Entities:  

Keywords:  Backscattering; Deep learning; ECG; EMG; EOG; Fully-passive

Mesh:

Year:  2022        PMID: 34837215     DOI: 10.1007/978-1-0716-1803-5_45

Source DB:  PubMed          Journal:  Methods Mol Biol        ISSN: 1064-3745


  5 in total

1.  Soft microfluidic assemblies of sensors, circuits, and radios for the skin.

Authors:  Sheng Xu; Yihui Zhang; Lin Jia; Kyle E Mathewson; Kyung-In Jang; Jeonghyun Kim; Haoran Fu; Xian Huang; Pranav Chava; Renhan Wang; Sanat Bhole; Lizhe Wang; Yoon Joo Na; Yue Guan; Matthew Flavin; Zheshen Han; Yonggang Huang; John A Rogers
Journal:  Science       Date:  2014-04-04       Impact factor: 47.728

2.  A point-score system for the ECG diagnosis of left ventricular hypertrophy.

Authors:  D W Romhilt; E H Estes
Journal:  Am Heart J       Date:  1968-06       Impact factor: 4.749

3.  Eye movement analysis for activity recognition using electrooculography.

Authors:  Andreas Bulling; Jamie A Ward; Hans Gellersen; Gerhard Tröster
Journal:  IEEE Trans Pattern Anal Mach Intell       Date:  2011-04       Impact factor: 6.226

4.  Long-term risk of recurrent atrial fibrillation as documented by an implantable monitoring device: implications for optimal patient care.

Authors:  Carsten W Israel; Gerian Grönefeld; Joachim R Ehrlich; Yi-Gang Li; Stefan H Hohnloser
Journal:  J Am Coll Cardiol       Date:  2004-01-07       Impact factor: 24.094

5.  Battery-free, stretchable optoelectronic systems for wireless optical characterization of the skin.

Authors:  Jeonghyun Kim; Giovanni A Salvatore; Hitoshi Araki; Antonio M Chiarelli; Zhaoqian Xie; Anthony Banks; Xing Sheng; Yuhao Liu; Jung Woo Lee; Kyung-In Jang; Seung Yun Heo; Kyoungyeon Cho; Hongying Luo; Benjamin Zimmerman; Joonhee Kim; Lingqing Yan; Xue Feng; Sheng Xu; Monica Fabiani; Gabriele Gratton; Yonggang Huang; Ungyu Paik; John A Rogers
Journal:  Sci Adv       Date:  2016-08-03       Impact factor: 14.136

  5 in total
  1 in total

1.  Mechanism of Hyperbaric Oxygen Combined with Astaxanthin Mediating Keap1/Nrf2/HO-1 Pathway to Improve Exercise Fatigue in Mice.

Authors:  Zheng Zhang; Binghong Gao
Journal:  Comput Intell Neurosci       Date:  2022-07-13
  1 in total