Association of device-measured physical activity with peak oxygen consumption measured by cardiopulmonary exercise testing in patients with cardiac implantable electronic devices.

Yasushi Wakabayashi1, Masanori Kobayashi2, Tomohide Ichikawa2, Takashi Koyama2, Hidetoshi Abe2.   

Abstract

PURPOSE: Cardiac implantable electronic devices (CIEDs) offer diagnostic information such as device-measured physical activity (PA). Peak oxygen consumption (VO2) measured by cardiopulmonary exercise testing (CPET) is the most objective variable showing exercise capacity. The purpose of this study was to investigate the relationship between these 2 variables.
METHODS: We retrospectively studied consecutive patients with CIEDs undergoing CPET between April 1, 2018, and January 31, 2021. These patients were divided into 2 groups: patients with peak VO2 ≤ 14 ml/kg/min (low peak VO2 group) and those showing peak VO2 > 14 ml/kg/min (high peak VO2 group). The peak device-measured PA was compared between the 2 groups. The relationship between the peak device-measured PA and peak VO2 was also investigated.
RESULTS: There were 50 and 51 patients in the low and high peak VO2 groups, respectively. The peak device-measured PA, which was expressed in units of hours/day, was significantly lower in the low peak VO2 group than in the high peak VO2 group (3.06, interquartile range [2.43-4.00] vs. 5.50, interquartile range [4.04-6.70] p < 0.01). The peak device-measured PA and peak VO2 showed a significant positive correlation (Spearman's ρ = 0.53; p < 0.01). Furthermore, receiver operating characteristic curve analysis showed that a peak device-measured PA > 3.87 h/day could predict high peak VO2 (80.4%, sensitivity; 72.0%, specificity). In multivariate linear regression analysis, peak device-measured PA was an independent predictor of peak VO2 (regression coefficient, 0.61; 95% confidence interval, 0.33-0.89; p < 0.01).
CONCLUSIONS: Peak device-measured PA was significantly associated with peak VO2.
© 2021. The Author(s), under exclusive licence to Springer Science+Business Media, LLC, part of Springer Nature.

Entities:  

Keywords:  Cardiac implantable electronic device; Cardiopulmonary exercise testing; Device-measured physical activity; Peak oxygen consumption

Mesh:

Year:  2021        PMID: 34826015     DOI: 10.1007/s10840-021-01095-8

Source DB:  PubMed          Journal:  J Interv Card Electrophysiol        ISSN: 1383-875X            Impact factor:   1.900


  1 in total

1.  Body composition and mortality in patients undergoing endovascular treatment for peripheral artery disease.

Authors:  Tadashi Itagaki; Soichiro Ebisawa; Kyuhachi Otagiri; Tamon Kato; Takashi Miura; Yusuke Kanzaki; Naoyuki Abe; Daisuke Yokota; Takashi Yanagisawa; Keisuke Senda; Yoshiteru Okina; Tadamasa Wakabayashi; Yushi Oyama; Kenichi Karube; Keisuke Machida; Takahiro Takeuchi; Tatsuya Saigusa; Hirohiko Motoki; Hiroshi Kitabayashi; Koichiro Kuwahara