Literature DB >> 34817782

Long-term changes in ocular rigidity following scleral buckling for rhegmatogenous retinal detachment.

Abdussalam M Abdullatif1, Ahmed Saad Albalkini1, Mohamed Saad Albalkini2, Tamer A Macky3, Ayman Khattab1, Mohamed Attya1.   

Abstract

PURPOSE: To investigate the long-term effect of scleral buckling on corneal biomechanics and the effect of change of scleral properties on intraocular pressure (IOP) measurements.
METHODS: This is a prospective case series, patients with rhegmatogenous retinal detachment prepared for scleral buckling were included. Goldmann applanation tonometry was used to measure IOP (GAT IOP). Ocular Response Analyzer (ORA) was used to measure corneal hysteresis (CH), corneal resistance factor (CRF), goldmann-corrected IOP (IOPg), and corneal-compensated IOP (IOPcc) preoperatively, and 1, 3, and 6 months postoperatively.
RESULTS: Thirty-three eyes included in the final analysis, with an average age 38.4 ± 16.2 years. CH and CRF decreased significantly at first, third, sixth months post-scleral buckling; however, this effect decreased with time as follows; preoperative: 8.9 ± 1.5 and 8.5 ± 2.1, first month: 6.8 ± 1.6 and 7.1 ± 1.8 (P value = 0.00, 0.002), third month: 7.8 ± 1.5 and 7.6 ± 1.6 (P value = 0.001, 0.008), and sixth month: 7.7 ± 1.3 and 7.6 ± 1.7 (P value = 0.002, 0.055). IOP cc was 19.3 ± 3.6, 17.1 ± 4, and 17.6 ± 2.9 at 1, 3, and 6 months, and these readings were significantly higher than GAT (13.6 ± 7.6, 12.4 ± 5.1, and 12.1 ± 2.9, P values = 0.00) and IOPg (14.9 ± 3.6, 13.5 ± 4.1, and 13.9 ± 3.5, P values = 0.00). The change in CH at each visit is correlated with the difference between the IOPcc and GAT measurements.
CONCLUSION: The conventional Goldmann applanation tonometry underestimates post buckle IOP measurements due corneal biomechanics changes. ORA might be an alternative and accurate method of measurement; however, further investigation is warranted.
© 2021. The Author(s), under exclusive licence to Springer Nature B.V.

Entities:  

Keywords:  Corneal biomechanics; Intraocular pressure; Rigidity; Scleral buckling

Mesh:

Year:  2021        PMID: 34817782     DOI: 10.1007/s10792-021-02138-9

Source DB:  PubMed          Journal:  Int Ophthalmol        ISSN: 0165-5701            Impact factor:   2.031


  2 in total

1.  Topical corticosteroid and intraocular pressure in high myopia. I. Study of pressure response.

Authors:  S K Amba; I S Jain; S D Gupta
Journal:  Indian J Ophthalmol       Date:  1973-09       Impact factor: 1.848

2.  Retinal safety evaluation of photoacoustic microscopy.

Authors:  Yanxiu Li; Wei Zhang; Van Phuc Nguyen; Naheed Wali Khan; Xiaobo Xia; Xueding Wang; Yannis M Paulus
Journal:  Exp Eye Res       Date:  2020-11-24       Impact factor: 3.467

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.