Literature DB >> 34813966

Effect of orthodontic maxillary posterior en masse intrusion anchored with miniplates on maxillary sinuses volume. Retrospective CBCT study.

Maila Izabela Pêsso Portes1, Ertty Ertty1, Fernanda Meloti1, Tien-Li An2, Ana Cláudia de Castro Ferrreira Conti3, Mauricio de Almeida Cardoso1.   

Abstract

OBJECTIVE: To evaluate, by means of cone beam computed tomography (CBCT), the volume change of maxillary sinuses in patients that underwent orthodontic maxillary posterior en masse intrusion anchored with miniplates.
MATERIALS AND METHODS: The sample consisted of pretreatment (T1) and posttreatment (T2) CBCT scans obtained from 14 patients (4 male and 10 female), with a mean age of 32.4 years, that underwent orthodontic maxillary posterior en masse intrusion anchored with miniplates in the zygomatic crest. The mean treatment duration was 20 months and the mean intrusion movement was 2.4 mm. Maxillary sinus volume was measured by means of the software ITK SNAP (version 3.8.0) in T1 and T2 CBCT scans. The changes in sinuses volume were calculated by T1-T2 values. Data were analyzed statistically with Wilcoxon test at 5% of level of significance and the method error was analyzed with Wilcoxon test, intraclass correlation and Dahlberg's formula.
RESULTS: The mean difference (T1-T2) was -242.85 mm³ (p = 0.396) for the right sinus and -32.5 mm³ (p = 0.875) for the left sinus. A slight increase in the volume of the sinuses was shown although these results were not statistically significant.
CONCLUSION: The orthodontic maxillary posterior en masse intrusion anchored with miniplates did not influence significantly the maxillary sinus volume.
Copyright © 2021 Elsevier Masson SAS. All rights reserved.

Entities:  

Keywords:  Anterior open bite; Computed tomography; Maxillary sinus; Miniplates

Mesh:

Year:  2021        PMID: 34813966     DOI: 10.1016/j.jormas.2021.11.004

Source DB:  PubMed          Journal:  J Stomatol Oral Maxillofac Surg        ISSN: 2468-7855            Impact factor:   2.480


  2 in total

1.  What changes in the biology of bone movement induced with mini-implants/miniplates is the synchronicity.

Authors:  Alberto Consolaro; Ertty Silva; Maurício de Almeida Cardoso
Journal:  Dental Press J Orthod       Date:  2022-07-04

2.  Quality assurance and long-term stability of a novel 3-in-1 X-ray system for brachytherapy.

Authors:  Andre Karius; Juliane Szkitsak; Vasilios Boronikolas; Rainer Fietkau; Christoph Bert
Journal:  J Appl Clin Med Phys       Date:  2022-07-18       Impact factor: 2.243

  2 in total